1.5-ton central heat pump · MVC series
MDV MOD30U-30HFN1-MR0
Very good cooling efficiency and below average heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.
Ranks #38 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $642 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 17,800 BTU/h79% of its 47°F outputBelow average · beats 0%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | MOD30U-30HFN1-MR0 |
| Series | MVC series |
| Type | Central heat pump |
| Nominal size | 1.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | July 21, 2023 |
| Last certified | June 3, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 19.0) |
| EER2Efficiency at 95°F outdoors | 13.0 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.2 |
| Capacity at 47°F | 22,600 BTU/h |
| Capacity at 17°F | 12,800 BTU/h |
| Capacity at 5°F | 17,800 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.50 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVC-18HWFN1-M at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MVC-18HWFN1-M | 19.0 | 13.0 | 8.2 | 17,800 | 213214821 |
Yearly running cost in 10 large cities
- Phoenix, AZ$616/yr
- Miami, FL$452/yr
- Houston, TX$555/yr
- Atlanta, GA$642/yr
- Los Angeles, CA$643/yr
- New York, NY$1,635/yr
- Chicago, IL$1,347/yr
- Denver, CO$1,135/yr
- Seattle, WA$710/yr
- Minneapolis, MN$1,412/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOD30U-30HFN1-MR0?
- The MDV MOD30U-30HFN1-MR0 is rated at up to 19.0 SEER2 and 13.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the MDV MOD30U-30HFN1-MR0 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
- How much does the MDV MOD30U-30HFN1-MR0 cost to run per year?
- At its rated efficiency it costs about $452-$1,635 a year in electricity in large U.S. cities, depending on climate and local rates - for example $616 in Phoenix and $1,412 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOD30U-30HFN1-MR0?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses MVC-18HWFN1-M.
- What refrigerant does the MDV MOD30U-30HFN1-MR0 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 1.5 ton models
- Goodman GZV6SA1810A · cold climate19.0 SEER2 · 8.8 HSPF2
- Arcoaire D5CURAH18AAK18.8 SEER2 · 9.4 HSPF2
- Daikin DH6VSA1810A · cold climate19.0 SEER2 · 8.8 HSPF2
- Carrier 37MURAQ18AA318.8 SEER2 · 9.4 HSPF2
- ZERO ZSOVA-18HDMB-USHH · cold climate19.0 SEER2 · 9.7 HSPF2
- DuraSTAR DRU1U18S2A18.8 SEER2 · 9.4 HSPF2
- Panasonic CU-HM18BAHU · cold climate19.0 SEER2 · 9.7 HSPF2
- Innovair SOV18H2BA18.8 SEER2 · 9.4 HSPF2
See all 170 1.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 3, 2026. How we use the data.