HVAC Rated

2.5-ton central heat pump · 4SHP17 SERIES

Armstrong Air 4SHP17LE130P-**A

Below average cooling efficiency and average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #114 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $893 a year to run in a mixed climate like Atlanta.

SEER2
16.2 Cooling efficiency over a season
Below average · beats 36%
HSPF2
8.6 Heating efficiency over a season
Average · beats 45%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
15,400 BTU/h49% of its 47°F output
Excellent · beats 94%

A good fit if…

  • You want a choice of indoor units - 667 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandArmstrong Air
Also sold asAIREASE, ALLIED
Outdoor unit model4SHP17LE130P-**A
Series4SHP17 SERIES
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 6, 2022
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.2 (range 15.2-16.2)
EER2Efficiency at 95°F outdoors12.2-13.5
Cooling capacity28,200-30,600 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.6
Capacity at 47°F26,600-30,000 BTU/h
Capacity at 17°F17,200-19,600 BTU/h
Capacity at 5°F13,200-15,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.38
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAD4X-42B+TDR at the standard test temperatures, in BTU/h:

Certified matchups667 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 667 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAD4X-42B+TDRA80DF1E090B1616.213.58.614,800213264826
EAD4X-42B+TDRA80DF1E090B1616.213.58.614,800213264952
7ED42BX-0*+TDRA80DF1E090B1616.213.58.614,800214713969
7ED42BX-0*+TDRA80DF1E090B1616.213.58.614,800214715462
EA(C;U)1P36A+TDR+TXVA80UH1E090B1616.213.08.114,100210329390
EA(C;U)1P36A+TDR+TXVA80US2V060A12X16.213.08.114,500210329387
EA(C;U)1P36A+TDR+TXVA80US2V090B1216.213.08.114,500210329404
EA(C;U)1P36A+TDR+TXVA80UH2E090B1616.213.08.114,100210330001
EA(C;U)1P36A+TDR+TXVA80US2V080B16X16.213.08.114,500210329403
EA(C;U)1P36A+TDR+TXVA80UH2E090B1216.213.08.114,300210330007
EA(C;U)1P36B+TDR+TXVA80UH2E090B1616.213.08.114,100211662483
EA(C;U)1P36B+TDR+TXVA80UH2E090B1216.213.08.114,300211662482
EA(C;U)1P36B+TDR+TXVA80UH1E090B1616.213.08.114,100211662489
EAC4X36B+TDRA80US2V080B16X16.213.08.114,500211662573
EAC4X36B+TDRA80US2V090B1216.213.08.114,500211662574
EAC4X36B+TDRA80UH2E090B1616.213.08.114,100211662560
EAC4X36B+TDRA80UH2E090B1216.213.08.114,300211662559
EA(C;U)1P36B+TDR+TXVA80UH1E090B1616.213.08.114,100211663007
EA(C;U)1P36B+TDR+TXVA80US2V080B16X16.213.08.114,500211663014
EA(C;U)1P36B+TDR+TXVA80US2V090B1216.213.08.114,500211663015
EAC4X36B+TDRA80UH1E090B1616.213.08.114,100211663084
EA(C;U)1P36A+TDR+TXVA80UH2E090B1616.213.08.114,100210329391
EA(C;U)1P36A+TDR+TXVA80UH2E090B1216.213.08.114,300210329397
EA(C;U)1P36A+TDR+TXVA80UH1E090B1616.213.08.114,100210330000
EAC4X36A+TDRA80US2V060A12X16.213.08.114,500211662555
EAC4X36B+TDRA80UH1E090B1616.213.08.114,100211662566
EA(C;U)1P36B+TDR+TXVA80UH2E090B1216.213.08.114,300211663000
EA(C;U)1P36B+TDR+TXVA80UH2E090B1616.213.08.114,100211663001
EAC4X36B+TDRA80UH2E090B1216.213.08.114,300211663077
EAC4X36B+TDRA80UH2E090B1616.213.08.114,100211663078
EAC4X36A+TDRA80US2V060A12X16.213.08.114,500211663073
EA(C;U)1P36A+TDR+TXVA80US2V080B16X16.213.08.114,500210330013
EA(C;U)1P36B+TDR+TXVA80US2V080B16X16.213.08.114,500211662496
EA(C;U)1P36B+TDR+TXVA80US2V090B1216.213.08.114,500211662497
EA(C;U)1P36A+TDR+TXVA80US2V090B1216.213.08.114,500210330014
EA(C;U)1P36A+TDR+TXVA80US2V060A12X16.213.08.114,500210329997
EAC4X36B+TDRA80US2V090B1216.213.08.114,500211663092
EAC4X36B+TDRA80US2V080B16X16.213.08.114,500211663091
7EC36BX-0*+TDRA80UH2E090B1616.213.08.114,100214714019
7EC36BX-0*+TDRA80UH1E090B1616.213.08.114,100214714025
7EC36AX-0*+TDRA80US2V060A12X16.213.08.114,500214714013
7EC36BX-0*+TDRA80UH2E090B1216.213.08.114,300214714018
7EC36BX-0*+TDRA80US2V080B16X16.213.08.114,500214714032
7EC36BX-0*+TDRA80US2V090B1216.213.08.114,500214714033
7EC36BX-0*+TDRA80US2V080B16X16.213.08.114,500214715525
7EC36BX-0*+TDRA80US2V090B1216.213.08.114,500214715526
7EC36AX-0*+TDRA80US2V060A12X16.213.08.114,500214715506
7EC36BX-0*+TDRA80UH1E090B1616.213.08.114,100214715518
7EC36BX-0*+TDRA80UH2E090B1216.213.08.114,300214715511
7EC36BX-0*+TDRA80UH2E090B1616.213.08.114,100214715512
EAH1P36C*+TDR+TXVA80UH1E100C20X16.213.08.013,800211735921
EAH1P36C*+TDR+TXVA80UH1E100C20X16.213.08.013,800211735919
7EH30BX-0*+TDRA80UH2E090B1216.213.08.013,500214713914
7EH30BX-0*+TDRA80US2V080B16X16.213.08.013,800214713928
7EH30BX-0*+TDRA80US2V090B1216.213.08.013,800214713929
7EH30BX-0*+TDRA80US2V080B16X16.213.08.013,800214715421
7EH30BX-0*+TDRA80US2V090B1216.213.08.013,800214715422
7EH30BX-0*+TDRA80UH2E090B1216.213.08.013,500214715407
7EH30BX-0*+TDRA80UH1E070B1216.213.07.813,400214713920
7EH30BX-0*+TDRA80UH1E090B1616.213.07.813,400214713921
Yearly running cost in 10 large cities$844-$2,097

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Armstrong Air 4SHP17LE130P-**A?
The Armstrong Air 4SHP17LE130P-**A is rated at up to 16.2 SEER2 and 13.5 EER2 for cooling and up to 8.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 667 certified matchups SEER2 ranges from 15.2-16.2.
Is the Armstrong Air 4SHP17LE130P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Armstrong Air 4SHP17LE130P-**A cost to run per year?
At its rated efficiency it costs about $844-$2,097 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,019 in Phoenix and $1,734 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Armstrong Air 4SHP17LE130P-**A?
ENERGY STAR lists 667 certified combinations for this outdoor unit. The highest-rated ones use EAD4X-42B+TDR, 7ED42BX-0*+TDR, EA(C;U)1P36A+TDR+TXV.
What refrigerant does the Armstrong Air 4SHP17LE130P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $999/yrYou save $487/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Armstrong Air 4SHP17LE130P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$999
Current system, per year
$1,486
You save per year
$487
Payback
22.6 years
Net after 10 years
-$6,131

Cooling $634Heating $365Electricity used: 6,245 kWhSaved vs. a minimum-efficiency heat pump: $138

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.