2-ton central heat pump · BHP17 SERIES
Blueridge BHP17L24P-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #232 of 331 2 ton central heat pumps for cooling efficiency, and costs about $710 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 11,500 BTU/h47% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 143 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Blueridge |
| Outdoor unit model | BHP17L24P-**A |
| Series | BHP17 SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.4-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,600-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 21,000-22,600 BTU/h |
| Capacity at 17°F | 13,400-14,700 BTU/h |
| Capacity at 5°F | 10,200-11,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BH1P30B*+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 143 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BH1P30B*+TDR+TXV | BG802UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735148 |
| BH1P30B*+TDR+TXV | BG801UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735226 |
| BC730HBT-0*+TDR | BG802UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214713334 |
| BC730HBT-0*+TDR | BG801UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214713336 |
| BH1P30B*+TDR+TXV | BG801UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735210 |
| BC730HBT-0*+TDR | BG801UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214713335 |
| BH1P30B*+TDR+TXV | BG802UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735136 |
| BC730HBT-0*+TDR | BG802UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 214713333 |
| BC1P30A+TDR+TXV | BG801UH090BE16 | 16.6 | 13.5 | 8.0 | 10,400 | 210325513 |
| BC4X30B+TDR | BG801UH090BE16 | 16.6 | 13.5 | 8.0 | 10,400 | 210441241 |
| BC1P30B+TDR+TXV | BG801UH090BE16 | 16.6 | 13.5 | 8.0 | 10,400 | 210441205 |
| BH1P30B*+TDR+TXV | BG921UH070BE12 | 16.6 | 13.5 | 8.0 | 10,600 | 211735272 |
| BC730CBT-0*+TDR | BG801UH090BE16 | 16.6 | 13.5 | 8.0 | 10,400 | 214713373 |
| BC730HBT-0*+TDR | BG921UH070BE12 | 16.6 | 13.5 | 8.0 | 10,600 | 214713338 |
| BC730/36DCT-0*+TDR | BG96G1DF090CE16 | 16.4 | 13.5 | 8.2 | 11,200 | 214713347 |
| BH1P30A*+TDR+TXV | BG802UH070AV12 | 16.4 | 13.5 | 8.1 | 10,600 | 211735105 |
| BC730HAT-0*+TDR | BG802UH070AV12 | 16.4 | 13.5 | 8.1 | 10,600 | 214713331 |
| BC1P30B+TDR+TXV | BG802UH090BE16 | 16.4 | 13.5 | 8.0 | 10,400 | 210441202 |
| BH1P30A*+TDR+TXV | BG801UH045AE12 | 16.4 | 13.5 | 8.0 | 10,200 | 211735068 |
| BH1P30A*+TDR+TXV | BG801UH070AE12 | 16.4 | 13.5 | 8.0 | 10,400 | 211735082 |
| BC4X30B+TDR | BG802UH090BE16 | 16.4 | 13.5 | 8.0 | 10,400 | 210441238 |
| BC1P30A+TDR+TXV | BG802UH090BE16 | 16.4 | 13.5 | 8.0 | 10,400 | 210325514 |
| BC730HAT-0*+TDR | BG801UH045AE12 | 16.4 | 13.5 | 8.0 | 10,200 | 214713329 |
| BC730CBT-0*+TDR | BG802UH090BE16 | 16.4 | 13.5 | 8.0 | 10,400 | 214713371 |
| BC730HAT-0*+TDR | BG801UH070AE12 | 16.4 | 13.5 | 8.0 | 10,400 | 214713330 |
| BC1P24B+TDR+TXV | BG802UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210441191 |
| BC1P24A+TDR+TXV | BG802UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210325486 |
| BH1P24A*+TDR+TXV | BG801UH070AE12 | 16.4 | 13.5 | 7.8 | 10,400 | 211734978 |
| BC4X24B+TDR | BG801UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210441225 |
| BC4X30A+TDR | BG802UH070AV12 | 16.4 | 13.5 | 7.8 | 10,400 | 210441235 |
| BC4X30B+TDR | BG801UH070BE12 | 16.4 | 13.5 | 7.8 | 10,400 | 210441240 |
| BC1P30A+TDR+TXV | BG801UH070BE12 | 16.4 | 13.5 | 7.8 | 10,400 | 210325498 |
| BC1P24A+TDR+TXV | BG801UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210325484 |
| BC1P24A+TDR+TXV | BG801UH070BE12 | 16.4 | 13.0 | 7.8 | 10,400 | 210325469 |
| BC4X24B+TDR | BG801UH070BE12 | 16.4 | 13.0 | 7.8 | 10,400 | 210441224 |
| BC1P30A+TDR+TXV | BG802UH070AV12 | 16.4 | 13.5 | 7.8 | 10,400 | 210325496 |
| BC4X24B+TDR | BG802UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210441222 |
| BC1P24B+TDR+TXV | BG801UH070BE12 | 16.4 | 13.0 | 7.8 | 10,400 | 210441193 |
| BC1P30B+TDR+TXV | BG801UH070BE12 | 16.4 | 13.5 | 7.8 | 10,400 | 210441204 |
| BC1P24B+TDR+TXV | BG801UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 210441194 |
| BH1P30B*+TDR+TXV | BG802UH090BV16 | 16.4 | 13.5 | 7.8 | 10,400 | 211735343 |
| BC724HAT-0*+TDR | BG801UH070AE12 | 16.4 | 13.5 | 7.8 | 10,400 | 214713325 |
| BC730CBT-0*+TDR | BG801UH070BE12 | 16.4 | 13.5 | 7.8 | 10,400 | 214713372 |
| BC724CBT-0*+TDR | BG801UH070BE12 | 16.4 | 13.0 | 7.8 | 10,400 | 214713357 |
| BC730CAT-0*+TDR | BG802UH070AV12 | 16.4 | 13.5 | 7.8 | 10,400 | 214713368 |
| BC730HBT-0*+TDR | BG802UH090BV16 | 16.4 | 13.5 | 7.8 | 10,400 | 214713341 |
| BC724CBT-0*+TDR | BG802UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 214713356 |
| BC724CBT-0*+TDR | BG801UH090BE16 | 16.4 | 13.5 | 7.8 | 10,400 | 214713358 |
| BD4X-30/36B+TDR | BG80G1DF090BE16 | 16.2 | 13.5 | 8.2 | 11,200 | 213265507 |
| BC730/36DBT-0*+TDR | BG80G1DF090BE16 | 16.2 | 13.5 | 8.2 | 11,200 | 214713343 |
| BC1P30B+TDR+TXV | BG921UH070BE12 | 16.2 | 13.5 | 7.8 | 10,600 | 210441207 |
| BH1P24A*+TDR+TXV | BG802UH070AV12 | 16.2 | 13.5 | 7.8 | 10,600 | 211735003 |
| BH1P24A*+TDR+TXV | BG801UH045AE12 | 16.2 | 13.5 | 7.8 | 10,200 | 211734963 |
| BC4X30B+TDR | BG921UH070BE12 | 16.2 | 13.5 | 7.8 | 10,600 | 210441243 |
| BC1P30A+TDR+TXV | BG921UH070BE12 | 16.2 | 13.5 | 7.8 | 10,600 | 210325501 |
| BC4X24A+TDR | BG802UH070AV12 | 16.2 | 13.0 | 7.8 | 10,400 | 210441219 |
| BC4X30A+TDR | BG801UH070AE12 | 16.2 | 13.5 | 7.8 | 10,400 | 210441234 |
| BC4X24A+TDR | BG801UH070AE12 | 16.2 | 13.0 | 7.8 | 10,400 | 210441218 |
| BC4X30A+TDR | BG801UH045AE12 | 16.2 | 13.5 | 7.8 | 10,200 | 210441233 |
| BC1P30A+TDR+TXV | BG801UH070AE12 | 16.2 | 13.5 | 7.8 | 10,400 | 210325492 |
Yearly running cost in 10 large cities
- Phoenix, AZ$791/yr
- Miami, FL$646/yr
- Houston, TX$709/yr
- Atlanta, GA$710/yr
- Los Angeles, CA$690/yr
- New York, NY$1,689/yr
- Chicago, IL$1,370/yr
- Denver, CO$1,137/yr
- Seattle, WA$698/yr
- Minneapolis, MN$1,407/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Blueridge BHP17L24P-**A?
- The Blueridge BHP17L24P-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 143 certified matchups SEER2 ranges from 15.4-17.0.
- Is the Blueridge BHP17L24P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Blueridge BHP17L24P-**A cost to run per year?
- At its rated efficiency it costs about $646-$1,689 a year in electricity in large U.S. cities, depending on climate and local rates - for example $791 in Phoenix and $1,407 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Blueridge BHP17L24P-**A?
- ENERGY STAR lists 143 certified combinations for this outdoor unit. The highest-rated ones use BH1P30B*+TDR+TXV, BC730HBT-0*+TDR, BC1P30A+TDR+TXV.
- What refrigerant does the Blueridge BHP17L24P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Armstrong Air 4SHP17LE124P-**A17.0 SEER2 · 8.2 HSPF2
- Comfort-Aire HRG1524S1R-**A17.0 SEER2 · 8.2 HSPF2
- Daikin DZ6VSA241EA · cold climate17.0 SEER2 · 8.6 HSPF2
- Concord 4HP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Continental WSEHV2436RA1-C · cold climate17.0 SEER2 · 9.0 HSPF2
- GE NS17H24SA4-**A17.0 SEER2 · 8.2 HSPF2
- AC Pro AUD36W/A-D(U) · cold climate17.0 SEER2 · 9.0 HSPF2
- Lennox EL17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.