HVAC Rated

2-ton central heat pump · BHP17 SERIES

Blueridge BHP17L24P-**A

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #232 of 331 2 ton central heat pumps for cooling efficiency, and costs about $710 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
11,500 BTU/h47% of its 47°F output
Average · beats 67%

A good fit if…

  • You want a choice of indoor units - 143 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandBlueridge
Outdoor unit modelBHP17L24P-**A
SeriesBHP17 SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 25, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.4-17.0)
EER2Efficiency at 95°F outdoors12.5-14.0
Cooling capacity22,600-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F21,000-22,600 BTU/h
Capacity at 17°F13,400-14,700 BTU/h
Capacity at 5°F10,200-11,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.14
ENERGY STAR cold climateNo
Heating output as it gets colder47% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BH1P30B*+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups143 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 143 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BH1P30B*+TDR+TXVBG802UH090BE1617.014.08.010,300211735148
BH1P30B*+TDR+TXVBG801UH090BE1617.014.08.010,400211735226
BC730HBT-0*+TDRBG802UH090BE1617.014.08.010,300214713334
BC730HBT-0*+TDRBG801UH090BE1617.014.08.010,400214713336
BH1P30B*+TDR+TXVBG801UH070BE1216.813.58.010,400211735210
BC730HBT-0*+TDRBG801UH070BE1216.813.58.010,400214713335
BH1P30B*+TDR+TXVBG802UH090BE1216.813.57.810,300211735136
BC730HBT-0*+TDRBG802UH090BE1216.813.57.810,300214713333
BC1P30A+TDR+TXVBG801UH090BE1616.613.58.010,400210325513
BC4X30B+TDRBG801UH090BE1616.613.58.010,400210441241
BC1P30B+TDR+TXVBG801UH090BE1616.613.58.010,400210441205
BH1P30B*+TDR+TXVBG921UH070BE1216.613.58.010,600211735272
BC730CBT-0*+TDRBG801UH090BE1616.613.58.010,400214713373
BC730HBT-0*+TDRBG921UH070BE1216.613.58.010,600214713338
BC730/36DCT-0*+TDRBG96G1DF090CE1616.413.58.211,200214713347
BH1P30A*+TDR+TXVBG802UH070AV1216.413.58.110,600211735105
BC730HAT-0*+TDRBG802UH070AV1216.413.58.110,600214713331
BC1P30B+TDR+TXVBG802UH090BE1616.413.58.010,400210441202
BH1P30A*+TDR+TXVBG801UH045AE1216.413.58.010,200211735068
BH1P30A*+TDR+TXVBG801UH070AE1216.413.58.010,400211735082
BC4X30B+TDRBG802UH090BE1616.413.58.010,400210441238
BC1P30A+TDR+TXVBG802UH090BE1616.413.58.010,400210325514
BC730HAT-0*+TDRBG801UH045AE1216.413.58.010,200214713329
BC730CBT-0*+TDRBG802UH090BE1616.413.58.010,400214713371
BC730HAT-0*+TDRBG801UH070AE1216.413.58.010,400214713330
BC1P24B+TDR+TXVBG802UH090BE1616.413.57.810,400210441191
BC1P24A+TDR+TXVBG802UH090BE1616.413.57.810,400210325486
BH1P24A*+TDR+TXVBG801UH070AE1216.413.57.810,400211734978
BC4X24B+TDRBG801UH090BE1616.413.57.810,400210441225
BC4X30A+TDRBG802UH070AV1216.413.57.810,400210441235
BC4X30B+TDRBG801UH070BE1216.413.57.810,400210441240
BC1P30A+TDR+TXVBG801UH070BE1216.413.57.810,400210325498
BC1P24A+TDR+TXVBG801UH090BE1616.413.57.810,400210325484
BC1P24A+TDR+TXVBG801UH070BE1216.413.07.810,400210325469
BC4X24B+TDRBG801UH070BE1216.413.07.810,400210441224
BC1P30A+TDR+TXVBG802UH070AV1216.413.57.810,400210325496
BC4X24B+TDRBG802UH090BE1616.413.57.810,400210441222
BC1P24B+TDR+TXVBG801UH070BE1216.413.07.810,400210441193
BC1P30B+TDR+TXVBG801UH070BE1216.413.57.810,400210441204
BC1P24B+TDR+TXVBG801UH090BE1616.413.57.810,400210441194
BH1P30B*+TDR+TXVBG802UH090BV1616.413.57.810,400211735343
BC724HAT-0*+TDRBG801UH070AE1216.413.57.810,400214713325
BC730CBT-0*+TDRBG801UH070BE1216.413.57.810,400214713372
BC724CBT-0*+TDRBG801UH070BE1216.413.07.810,400214713357
BC730CAT-0*+TDRBG802UH070AV1216.413.57.810,400214713368
BC730HBT-0*+TDRBG802UH090BV1616.413.57.810,400214713341
BC724CBT-0*+TDRBG802UH090BE1616.413.57.810,400214713356
BC724CBT-0*+TDRBG801UH090BE1616.413.57.810,400214713358
BD4X-30/36B+TDRBG80G1DF090BE1616.213.58.211,200213265507
BC730/36DBT-0*+TDRBG80G1DF090BE1616.213.58.211,200214713343
BC1P30B+TDR+TXVBG921UH070BE1216.213.57.810,600210441207
BH1P24A*+TDR+TXVBG802UH070AV1216.213.57.810,600211735003
BH1P24A*+TDR+TXVBG801UH045AE1216.213.57.810,200211734963
BC4X30B+TDRBG921UH070BE1216.213.57.810,600210441243
BC1P30A+TDR+TXVBG921UH070BE1216.213.57.810,600210325501
BC4X24A+TDRBG802UH070AV1216.213.07.810,400210441219
BC4X30A+TDRBG801UH070AE1216.213.57.810,400210441234
BC4X24A+TDRBG801UH070AE1216.213.07.810,400210441218
BC4X30A+TDRBG801UH045AE1216.213.57.810,200210441233
BC1P30A+TDR+TXVBG801UH070AE1216.213.57.810,400210325492
Yearly running cost in 10 large cities$646-$1,689

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Blueridge BHP17L24P-**A?
The Blueridge BHP17L24P-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 143 certified matchups SEER2 ranges from 15.4-17.0.
Is the Blueridge BHP17L24P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Blueridge BHP17L24P-**A cost to run per year?
At its rated efficiency it costs about $646-$1,689 a year in electricity in large U.S. cities, depending on climate and local rates - for example $791 in Phoenix and $1,407 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Blueridge BHP17L24P-**A?
ENERGY STAR lists 143 certified combinations for this outdoor unit. The highest-rated ones use BH1P30B*+TDR+TXV, BC730HBT-0*+TDR, BC1P30A+TDR+TXV.
What refrigerant does the Blueridge BHP17L24P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $782/yrYou save $398/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BHP17L24P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$782
Current system, per year
$1,180
You save per year
$398
Payback
22.6 years
Net after 10 years
-$5,019

Cooling $485Heating $298Electricity used: 4,889 kWhSaved vs. a minimum-efficiency heat pump: $119

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.