2-ton central heat pump · HRG17 SERIES
Comfort-Aire HRG1524S1R-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #233 of 331 2 ton central heat pumps for cooling efficiency, and costs about $710 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 11,500 BTU/h48% of its 47°F outputAverage · beats 67%
A good fit if…
- You want a choice of indoor units - 155 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | HRG1524S1R-**A |
| Series | HRG17 SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.4-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,600-23,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 21,200-22,600 BTU/h |
| Capacity at 17°F | 13,400-14,700 BTU/h |
| Capacity at 5°F | 10,200-11,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.14 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7EH30BX-0*+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 155 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| 7EH30BX-0*+TDR | GUH80C090B4M | 17.0 | 14.0 | 8.0 | 10,400 | 214712881 |
| 7EH30BX-0*+TDR | GUH80C090B4M | 17.0 | 14.0 | 8.0 | 10,400 | 214716705 |
| 7EH30BX-0*+TDR | GUH80C070B3M | 16.8 | 13.5 | 8.0 | 10,400 | 214712880 |
| 7EH30BX-0*+TDR | GUH80C070B3M | 16.8 | 13.5 | 8.0 | 10,400 | 214716704 |
| 7EH30BX-0*+TDR | GUH97M070B3M | 16.8 | 13.5 | 7.8 | 10,400 | 214712886 |
| 7EH30BX-0*+TDR | GUH97M070B3M | 16.8 | 13.5 | 7.8 | 10,400 | 214716710 |
| EA(C;U)1P30A+TDR+TXV | GUH80C090B4M | 16.6 | 13.5 | 8.0 | 10,400 | 210331417 |
| EA(C;U)1P30A+TDR+TXV | GUH80C090B4M | 16.6 | 13.5 | 8.0 | 10,400 | 210330496 |
| 7EH30BX-0*+TDR | GUH92C070B3M | 16.6 | 13.5 | 8.0 | 10,600 | 214712883 |
| 7EC30BX-0*+TDR | GUH80C090B4M | 16.6 | 13.5 | 8.0 | 10,400 | 214712919 |
| 7EH30BX-0*+TDR | GUH92C070B3M | 16.6 | 13.5 | 8.0 | 10,600 | 214716707 |
| 7EC30BX-0*+TDR | GUH80C090B4M | 16.6 | 13.5 | 8.0 | 10,400 | 214716743 |
| EAD4X-30/36C+TDR | GDD96C090C4M | 16.4 | 13.5 | 8.2 | 11,200 | 213265428 |
| EAD4X-30/36C+TDR | GDD96C090C4M | 16.4 | 13.5 | 8.2 | 11,200 | 213265478 |
| 7ED30/36CX-0*+TDR | GDD96C090C4M | 16.4 | 13.5 | 8.2 | 11,200 | 214712895 |
| 7ED30/36CX-0*+TDR | GDD96C090C4M | 16.4 | 13.5 | 8.2 | 11,200 | 214716719 |
| 7EH30AX-0*+TDR | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 10,400 | 214712877 |
| 7EH30AX-0*+TDR | GUH80C045A3M | 16.4 | 13.5 | 8.0 | 10,200 | 214712876 |
| 7EH30AX-0*+TDR | GUH80C045A3M | 16.4 | 13.5 | 8.0 | 10,200 | 214716700 |
| 7EH30AX-0*+TDR | GUH80C070A3M | 16.4 | 13.5 | 8.0 | 10,400 | 214716701 |
| EAH1P24A+TDR+TXV | GUH80C070A3M | 16.4 | 13.5 | 7.8 | 10,400 | 210330497 |
| EA(C;U)1P24A+TDR+TXV | GUH97M070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 210330484 |
| EA(C;U)1P24A+TDR+TXV | GUH97M070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 210331404 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 210331397 |
| EA(C;U)1P24A+TDR+TXV | GUH80C090B4M | 16.4 | 13.5 | 7.8 | 10,400 | 210330485 |
| EA(C;U)1P24A+TDR+TXV | GUH80C090B4M | 16.4 | 13.5 | 7.8 | 10,400 | 210331405 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 210330488 |
| EA(C;U)1P30A+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 210331416 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 210331409 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 210330477 |
| EA(C;U)1P30A+TDR+TXV | GUH97M070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 210330495 |
| 7EH30BX-0*+TDR | GUH80X080B4M | 16.4 | 13.5 | 7.8 | 10,600 | 214712879 |
| 7EC24BX-0*+TDR | GUH80C070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 214712904 |
| 7EC24BX-0*+TDR | GUH80C090B4M | 16.4 | 13.5 | 7.8 | 10,400 | 214712905 |
| 7EC24BX-0*+TDR | GUH97M070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 214712910 |
| 7EC30BX-0*+TDR | GUH80C070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 214712918 |
| 7EC30BX-0*+TDR | GUH97M070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 214712924 |
| 7EH24AX-0*+TDR | GUH80C070A3M | 16.4 | 13.5 | 7.8 | 10,400 | 214716696 |
| 7EC24BX-0*+TDR | GUH97M070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 214716734 |
| 7EC24BX-0*+TDR | GUH80C070B3M | 16.4 | 13.0 | 7.8 | 10,400 | 214716728 |
| 7EC24BX-0*+TDR | GUH80C090B4M | 16.4 | 13.5 | 7.8 | 10,400 | 214716729 |
| 7EC30BX-0*+TDR | GUH80C070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 214716742 |
| 7EC30BX-0*+TDR | GUH97M070B3M | 16.4 | 13.5 | 7.8 | 10,400 | 214716748 |
| 7EH30BX-0*+TDR | GUH80X080B4M | 16.4 | 13.5 | 7.8 | 10,600 | 214716703 |
| 7EH24AX-0*+TDR | GUH80C070A3M | 16.4 | 13.5 | 7.8 | 10,400 | 214712872 |
| EAD4X-30/36C+TDR | GDD92C090C4M | 16.2 | 13.5 | 8.2 | 11,000 | 213265427 |
| EAD4X-30/36B+TDR | GDD80C090B4M | 16.2 | 13.5 | 8.2 | 11,200 | 213265421 |
| EAD4X-30/36B+TDR | GDD80C090B4M | 16.2 | 13.5 | 8.2 | 11,200 | 213265471 |
| EAD4X-30/36C+TDR | GDD92C090C4M | 16.2 | 13.5 | 8.2 | 11,000 | 213265477 |
| 7ED30/36BX-0*+TDR | GDD80C090B4M | 16.2 | 13.5 | 8.2 | 11,200 | 214712888 |
| 7ED30/36CX-0*+TDR | GDD92C090C4M | 16.2 | 13.5 | 8.2 | 11,000 | 214712894 |
| 7ED30/36CX-0*+TDR | GDD92C090C4M | 16.2 | 13.5 | 8.2 | 11,000 | 214716718 |
| 7ED30/36BX-0*+TDR | GDD80C090B4M | 16.2 | 13.5 | 8.2 | 11,200 | 214716712 |
| EAH1P24A+TDR+TXV | GUH80C045A3M | 16.2 | 13.5 | 7.8 | 10,200 | 210330498 |
| EAH1P30B+TDR+TXV | GUH92C045B3M | 16.2 | 13.5 | 7.8 | 10,600 | 210330502 |
| EA(C;U)1P24A+TDR+TXV | GUH80C070A3M | 16.2 | 13.0 | 7.8 | 10,400 | 210330475 |
| EA(C;U)1P30A+TDR+TXV | GUH92C070B3M | 16.2 | 13.5 | 7.8 | 10,600 | 210331411 |
| EA(C;U)1P30A+TDR+TXV | GUH92C070B3M | 16.2 | 13.5 | 7.8 | 10,600 | 210330490 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070A3M | 16.2 | 13.5 | 7.8 | 10,400 | 210330487 |
| EA(C;U)1P30A+TDR+TXV | GUH80C070A3M | 16.2 | 13.5 | 7.8 | 10,400 | 210331408 |
Yearly running cost in 10 large cities
- Phoenix, AZ$791/yr
- Miami, FL$646/yr
- Houston, TX$709/yr
- Atlanta, GA$710/yr
- Los Angeles, CA$690/yr
- New York, NY$1,689/yr
- Chicago, IL$1,370/yr
- Denver, CO$1,137/yr
- Seattle, WA$698/yr
- Minneapolis, MN$1,407/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire HRG1524S1R-**A?
- The Comfort-Aire HRG1524S1R-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 155 certified matchups SEER2 ranges from 15.4-17.0.
- Is the Comfort-Aire HRG1524S1R-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Comfort-Aire HRG1524S1R-**A cost to run per year?
- At its rated efficiency it costs about $646-$1,689 a year in electricity in large U.S. cities, depending on climate and local rates - for example $791 in Phoenix and $1,407 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire HRG1524S1R-**A?
- ENERGY STAR lists 155 certified combinations for this outdoor unit. The highest-rated ones use 7EH30BX-0*+TDR, EA(C;U)1P30A+TDR+TXV, 7EC30BX-0*+TDR.
- What refrigerant does the Comfort-Aire HRG1524S1R-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Blueridge BHP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Concord 4HP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Armstrong Air 4SHP17LE124P-**A17.0 SEER2 · 8.2 HSPF2
- GE NS17H24SA4-**A17.0 SEER2 · 8.2 HSPF2
- Daikin DZ6VSA241EA · cold climate17.0 SEER2 · 8.6 HSPF2
- Lennox EL17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Continental WSEHV2436RA1-C · cold climate17.0 SEER2 · 9.0 HSPF2
- Lennox ML17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.