2-ton central heat pump · A Series
Comfort-Aire A-VXP24SA-1
Very good cooling efficiency and excellent heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #117 of 331 2 ton central heat pumps for cooling efficiency, and costs about $652 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.3 Cooling efficiency over a seasonVery good · beats 74%
- HSPF2
- 10.5 Heating efficiency over a seasonExcellent · beats 96%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 21,600 BTU/h90% of its 47°F outputBelow average · beats 29%
A good fit if…
- You want low cooling bills - its SEER2 beats 74% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 96% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Comfort-Aire |
| Also sold as | Century |
| Outdoor unit model | A-VXP24SA-1 |
| Series | A Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | March 20, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.3 (range 16.0-18.3) |
| EER2Efficiency at 95°F outdoors | 10.0-11.7 |
| Cooling capacity | 23,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.5-10.5 |
| Capacity at 47°F | 24,000-25,000 BTU/h |
| Capacity at 17°F | 19,700-20,800 BTU/h |
| Capacity at 5°F | 19,600-21,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.96 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with B-VXP24SA-1 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| B-VXP24SA-1 · cold climate | 18.3 | 11.7 | 10.0 | 21,600 | 217169699 |
| B-VXP24SA-1 · cold climate | 18.3 | 11.7 | 10.0 | 21,600 | 217169705 |
| B-VXP24SA-1 · cold climate | 18.3 | 11.7 | 10.0 | 21,600 | 217618196 |
| WXP24SA · cold climate | 17.5 | 10.8 | 10.5 | 19,600 | 217482407 |
| WXP24SA · cold climate | 17.5 | 10.8 | 10.5 | 19,600 | 217482413 |
| WXP24SA · cold climate | 17.5 | 10.8 | 10.5 | 19,600 | 217618216 |
| MXP18/24A1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217169717 |
| MXP18/24B1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217169719 |
| MXP18/24A1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217169729 |
| MXP18/24B1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217169731 |
| MXP18/24A1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217618202 |
| MXP18/24B1A · cold climate | 16.0 | 10.0 | 9.5 | 21,000 | 217618204 |
Yearly running cost in 10 large cities
- Phoenix, AZ$742/yr
- Miami, FL$615/yr
- Houston, TX$665/yr
- Atlanta, GA$652/yr
- Los Angeles, CA$629/yr
- New York, NY$1,532/yr
- Chicago, IL$1,239/yr
- Denver, CO$1,026/yr
- Seattle, WA$627/yr
- Minneapolis, MN$1,268/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Comfort-Aire A-VXP24SA-1?
- The Comfort-Aire A-VXP24SA-1 is rated at up to 18.3 SEER2 and 11.7 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 12 certified matchups SEER2 ranges from 16.0-18.3.
- Is the Comfort-Aire A-VXP24SA-1 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 1.96, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Comfort-Aire A-VXP24SA-1 cost to run per year?
- At its rated efficiency it costs about $615-$1,532 a year in electricity in large U.S. cities, depending on climate and local rates - for example $742 in Phoenix and $1,268 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Comfort-Aire A-VXP24SA-1?
- ENERGY STAR lists 12 certified combinations for this outdoor unit. The highest-rated ones use B-VXP24SA-1, WXP24SA, MXP18/24A1A.
- What refrigerant does the Comfort-Aire A-VXP24SA-1 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Thermal Zone TZID24H520ZCS · cold climate18.4 SEER2 · 9.9 HSPF2
- Multi MFG HHS-24HD-B · cold climate18.3 SEER2 · 10.5 HSPF2
- MRCOOL CENTRAL-24-HP-C-230B00-O · cold climate18.4 SEER2 · 10.0 HSPF2
- CanAir 4CDH2024C21 · cold climate18.3 SEER2 · 10.0 HSPF2
- InfinityLiving EZ-24-HPB · cold climate18.4 SEER2 · 10.0 HSPF2
- Capella CCB1-H24A-O · cold climate18.3 SEER2 · 10.0 HSPF2
- MDV MOX430U-24HFN1-MR0 · cold climate18.4 SEER2 · 10.2 HSPF2
- DIRECT AIR DIRM4-24MAGICPRO20-OU · cold climate18.3 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.