HVAC Rated

2-ton central heat pump · MVP Series

MRCOOL CENTRAL-24-HP-C-230B00-O

Very good cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #115 of 331 2 ton central heat pumps for cooling efficiency, and costs about $670 a year to run in a mixed climate like Atlanta.

SEER2
18.4 Cooling efficiency over a season
Very good · beats 75%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
21,600 BTU/h90% of its 47°F output
Below average · beats 20%

A good fit if…

  • You want low cooling bills - its SEER2 beats 75% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandMRCOOL
Outdoor unit modelCENTRAL-24-HP-C-230B00-O
SeriesMVP Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 25, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.4 (range 15.8-18.4)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity23,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F24,000-25,000 BTU/h
Capacity at 17°F18,000-20,800 BTU/h
Capacity at 5°F20,000-21,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder90% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVP-24-HP-MUAH-230A00-O at the standard test temperatures, in BTU/h:

Certified matchups52 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
MVP-24-HP-MUAH-230A00-O · cold climate-18.411.710.021,600216032530
MCMP1824BOTB · cold climateMGM96EE060B3NB17.810.89.220,000217666230
**AECMPT24B2AA · cold climateMGM96EE060B3NB17.810.89.220,000217666256
MCMP1824BOTB · cold climateMGM96EE080B3NB17.610.79.320,000217666231
**AECMPT24B2AA · cold climateMGM96EE080B3NB17.610.79.320,000217666257
**AECMPT24A2AA · cold climateGR9T960403AN17.610.39.121,000218425120
MCMP1824AOTB · cold climateGR9T960403AN17.610.39.121,000218425060
**AECMPT24A2AA · cold climateGR9T960303AN17.410.29.221,000218425119
MCMP1824AOTB · cold climateGR9T960303AN17.410.29.221,000218425059
MCMP1824BOTB · cold climateS9V2B040U3VS***17.210.58.520,000217747095
MCMP1824BOTB · cold climateS9V2B060D3VS***17.210.58.520,000217747098
MCMP1824BOTB · cold climateS9V2B060U4VS***17.210.58.520,000217747101
**AECMPT24B2AA · cold climateS9V2B040U3VS***17.210.58.520,000217747111
**AECMPT24B2AA · cold climateS9V2B060D3VS***17.210.58.520,000217747114
**AECMPT24B2AA · cold climateS9V2B060U4VS***17.210.58.520,000217747117
**AECMPT24A2AA · cold climateGR9S920403AN17.110.39.120,000218425117
MCMP1824AOTB · cold climateGR9S920403AN17.110.39.120,000218425057
**AECMPT24B2AA · cold climateGD9S960603BN17.010.39.320,000218425129
MCMP1824BOTB · cold climateGD9S960603BN17.010.39.320,000218425069
**AECMPT24B2AA · cold climateMGA80SE080B4C16.710.49.220,000218029435
MCMP1824BOTB · cold climateMGA80SE080B4C16.710.49.220,000218029408
**AECMPT24A2AA · cold climateGR9T960603AN16.510.39.221,000218425121
MCMP1824AOTB · cold climateGR9T960603AN16.510.39.221,000218425061
**AECMPT24B2AA · cold climateMGA80SE060B4C16.510.39.120,000218029434
MCMP1824BOTB · cold climateMGA80SE060B4C16.510.39.120,000218029407
MCMP1824BOTB · cold climateRG19060B12MPS116.410.69.621,000217747090
**AECMPT24B2AA · cold climateRG19060B12MPS116.410.69.621,000217747106
**AECMPT24B2AA · cold climateGR9S920603BN16.210.49.320,000218425122
MCMP1824BOTB · cold climateGR9S920603BN16.210.49.320,000218425062
**AECMPT24A2AA · cold climateGR9S960403AN16.210.29.121,000218425118
MCMP1824AOTB · cold climateGR9S960403AN16.210.29.121,000218425058
**AECMPT24B2AA · cold climateGD9T960603BN16.110.39.320,000218425131
MCMP1824BOTB · cold climateGD9T960603BN16.110.39.320,000218425071
**AECMPT24A2AA · cold climate-16.010.09.521,000217666209
**AECMPT24B2AA · cold climate-16.010.09.521,000217666212
**AECMPT24B2AA · cold climateGR9T960803BN16.010.39.220,000218425127
MCMP1824BOTB · cold climateGR9T960803BN16.010.39.220,000218425067
**AECMPT24A2AA · cold climateMGA80SE040A3C16.010.08.920,000218029433
**AECMPT24B2AA · cold climateGD9T960803BN15.910.29.320,000218425132
**AECMPT24B2AA · cold climateGR9S960803BN15.910.39.320,000218425125
**AECMPT24B2AA · cold climateGR9S920803BN15.910.39.320,000218425123
MCMP1824BOTB · cold climateGD9T960803BN15.910.29.320,000218425072
MCMP1824BOTB · cold climateGR9S960803BN15.910.39.320,000218425065
MCMP1824BOTB · cold climateGR9S920803BN15.910.39.320,000218425063
**AECMPT24B2AA · cold climateGR9S960603BN15.910.39.220,000218425124
MCMP1824BOTB · cold climateGR9S960603BN15.910.39.220,000218425064
**AECMPT24B2AA · cold climateGD9T960403BN15.810.29.220,000218425130
**AECMPT24B2AA · cold climateGD9S960403BN15.810.29.220,000218425128
**AECMPT24B2AA · cold climateGR9T960603BN15.810.39.220,000218425126
MCMP1824BOTB · cold climateGD9T960403BN15.810.29.220,000218425070
MCMP1824BOTB · cold climateGD9S960403BN15.810.29.220,000218425068
MCMP1824BOTB · cold climateGR9T960603BN15.810.39.220,000218425066
Yearly running cost in 10 large cities$612-$1,591

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the MRCOOL CENTRAL-24-HP-C-230B00-O?
The MRCOOL CENTRAL-24-HP-C-230B00-O is rated at up to 18.4 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 52 certified matchups SEER2 ranges from 15.8-18.4.
Is the MRCOOL CENTRAL-24-HP-C-230B00-O good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the MRCOOL CENTRAL-24-HP-C-230B00-O cost to run per year?
At its rated efficiency it costs about $612-$1,591 a year in electricity in large U.S. cities, depending on climate and local rates - for example $748 in Phoenix and $1,324 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the MRCOOL CENTRAL-24-HP-C-230B00-O?
ENERGY STAR lists 52 certified combinations for this outdoor unit. The highest-rated ones use MVP-24-HP-MUAH-230A00-O, MCMP1824BOTB, **AECMPT24B2AA.
What refrigerant does the MRCOOL CENTRAL-24-HP-C-230B00-O use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $739/yrYou save $515/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump MRCOOL CENTRAL-24-HP-C-230B00-O
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$739
Current system, per year
$1,254
You save per year
$515
Payback
17.5 years
Net after 10 years
-$3,853

Cooling $459Heating $280Electricity used: 4,620 kWhSaved vs. a minimum-efficiency heat pump: $225

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.