Below average cooling efficiency and average heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #270 of 331 2 ton central heat pumps for cooling efficiency, and costs about $713 a year to run in a mixed climate like Atlanta.

SEER2
16.4 Cooling efficiency over a season
Below average · beats 38%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
8.0 Cooling efficiency on a 95°F day
Below average · beats 0%
Heat at 5°F
16,300 BTU/h71% of its 47°F output
Below average · beats 2%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 16,300 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandBlueridge
Also sold asCooper&Hunter, AIREVANTAGE
Outdoor unit modelBNG1A24SCN
SeriesBNG Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMay 20, 2026
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.4 (range 16.4)
EER2Efficiency at 95°F outdoors8.0
Cooling capacity23,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.7
Capacity at 47°F23,000 BTU/h
Capacity at 17°F17,100 BTU/h
Capacity at 5°F16,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.78
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BNG1A24DH0 at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
BNG1A24DH0 · cold climate16.48.08.716,300218469229
Same unit, other model numbers2

These model numbers have exactly the same certified ratings and matchups as the Blueridge BNG1A24SCN: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$658-$1,688

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Blueridge BNG1A24SCN?
The Blueridge BNG1A24SCN is rated at up to 16.4 SEER2 and 8.0 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Blueridge BNG1A24SCN good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 16,300 BTU/h at 5°F with a COP of 1.78, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Blueridge BNG1A24SCN cost to run per year?
At its rated efficiency it costs about $658-$1,688 a year in electricity in large U.S. cities, depending on climate and local rates - for example $801 in Phoenix and $1,402 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Blueridge BNG1A24SCN the same as the Cooper&Hunter CH-ALT24HP24V-230VO?
Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Blueridge BNG1A24SCN?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses BNG1A24DH0.
What refrigerant does the Blueridge BNG1A24SCN use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $790/yrYou save $396/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BNG1A24SCN
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$790
Current system, per year
$1,186
You save per year
$396
Payback
21.5 years
Net after 10 years
-$4,538

Cooling $494Heating $296Electricity used: 4,936 kWhSaved vs. a minimum-efficiency heat pump: $120

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.