HVAC Rated

2-ton central heat pump · IDS Light

Bosch BOVA-24HDN1-M15G

Below average cooling efficiency and average heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #272 of 331 2 ton central heat pumps for cooling efficiency, and costs about $719 a year to run in a mixed climate like Atlanta.

SEER2
16.1 Cooling efficiency over a season
Below average · beats 34%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
16,800 BTU/h72% of its 47°F output
Below average · beats 8%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 16,800 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandBosch
Also sold asMidea
Outdoor unit modelBOVA-24HDN1-M15G
SeriesIDS Light
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceNovember 17, 2022
Last certifiedJune 9, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.1 (range 15.2-16.1)
EER2Efficiency at 95°F outdoors10.5-11.7
Cooling capacity18,000-23,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F18,000-23,800 BTU/h
Capacity at 17°F15,000-20,200 BTU/h
Capacity at 5°F12,900-16,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.81
ENERGY STAR cold climateYes
Heating output as it gets colder72% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BWA-18WN1-M16 at the standard test temperatures, in BTU/h:

Certified matchups4 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
BWA-18WN1-M16 · cold climate16.111.79.012,900212437267
BCA-18WN1-M16 · cold climate16.111.79.012,900212437269
BCA-24WN1-M16 · cold climate16.111.78.516,700212437270
BWA-24WN1-M16 · cold climate15.210.59.016,800212437268
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Bosch BOVA-24HDN1-M15G: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$681-$1,689

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Bosch BOVA-24HDN1-M15G?
The Bosch BOVA-24HDN1-M15G is rated at up to 16.1 SEER2 and 11.7 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 15.2-16.1.
Is the Bosch BOVA-24HDN1-M15G good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 16,800 BTU/h at 5°F with a COP of 1.81, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Bosch BOVA-24HDN1-M15G cost to run per year?
At its rated efficiency it costs about $681-$1,689 a year in electricity in large U.S. cities, depending on climate and local rates - for example $821 in Phoenix and $1,397 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Bosch BOVA-24HDN1-M15G the same as the Midea MOVA-24HDN1-M16G?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Bosch BOVA-24HDN1-M15G?
ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use BWA-18WN1-M16, BCA-18WN1-M16, BCA-24WN1-M16.
What refrigerant does the Bosch BOVA-24HDN1-M15G use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $805/yrYou save $405/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bosch BOVA-24HDN1-M15G
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$805
Current system, per year
$1,210
You save per year
$405
Payback
22.2 years
Net after 10 years
-$4,955

Cooling $512Heating $294Electricity used: 5,033 kWhSaved vs. a minimum-efficiency heat pump: $123

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.