HVAC Rated

3.5-ton central heat pump · IDS Light-LGWP

Bosch BOVA-60RXB-M15S

Average cooling efficiency and below average heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #34 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,429 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
39,500 BTU/h71% of its 47°F output
Below average · beats 14%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 39,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 19 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandBosch
Also sold asMidea
Outdoor unit modelBOVA-60RXB-M15S
SeriesIDS Light-LGWP
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 16, 2024
Last certifiedApril 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.0-17.0)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity34,200-55,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5
Capacity at 47°F34,200-56,000 BTU/h
Capacity at 17°F33,000-40,000 BTU/h
Capacity at 5°F31,000-39,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.87
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BIVA-48RCB-M20X at the standard test temperatures, in BTU/h:

Certified matchups19 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BIVA-48RCB-M20X · cold climate-17.011.78.533,600215225108
BIVA-36RCB-M20X · cold climate-17.011.78.534,200215225109
BIVB-48RCB-M20X · cold climate-17.011.78.533,600217895208
BIVB-36RCB-M20X · cold climate-17.011.78.534,200217895209
BIVA-60RCB-M20X · cold climate-16.510.08.539,500215225110
BIVB-60RCB-M20X · cold climate-16.510.08.539,500217895210
BMAC4248BBTA · cold climateBGH96M080B3C16.010.58.531,000215225111
BMAC4248CBTA · cold climateBGH96M080C4C16.010.58.531,600215225112
BMAC4248CBTA · cold climateBGH96M100C5C16.010.58.533,000215225113
BMAC4248DBTA · cold climateBGH96M100D5C16.010.58.533,000215225114
BMAC4248DBTA · cold climateBGH96M120D5C16.010.58.533,000215225115
BMAC4248BBTA · cold climateBGH97M080B3A16.010.58.531,000217895216
BMAC4248CBTA · cold climateBGH97M080C4A16.010.58.531,600217895217
BMAC4248DBTA · cold climateBGH97M100D5A16.010.58.533,000217895219
BMAC4248BBTA+BMXFBCTA · cold climate-16.010.58.531,000217895392
BMAC4248CBTA+BMXFCCTA · cold climate-16.010.58.533,000217895393
BMAC4248DBTA+BMXFDCTA · cold climate-16.010.58.533,000217895394
BMAC4248CBTA · cold climateBGH97M100C5A16.010.58.533,000217895218
BMAC4248DBTA · cold climateBGH97M120D5A16.010.58.533,000217895220
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Bosch BOVA-60RXB-M15S: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,233-$3,454

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Bosch BOVA-60RXB-M15S?
The Bosch BOVA-60RXB-M15S is rated at up to 17.0 SEER2 and 11.7 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 19 certified matchups SEER2 ranges from 16.0-17.0.
Is the Bosch BOVA-60RXB-M15S good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 39,500 BTU/h at 5°F with a COP of 1.87, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Bosch BOVA-60RXB-M15S cost to run per year?
At its rated efficiency it costs about $1,233-$3,454 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,541 in Phoenix and $2,902 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Bosch BOVA-60RXB-M15S the same as the Midea MOVB-60HDN10-M16G?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Bosch BOVA-60RXB-M15S?
ENERGY STAR lists 19 certified combinations for this outdoor unit. The highest-rated ones use BIVA-48RCB-M20X, BIVA-36RCB-M20X, BIVB-48RCB-M20X.
What refrigerant does the Bosch BOVA-60RXB-M15S use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,541/yrYou save $795/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bosch BOVA-60RXB-M15S
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,541
Current system, per year
$2,335
You save per year
$795
Payback
20.8 years
Net after 10 years
-$8,553

Cooling $921Heating $619Electricity used: 9,629 kWhSaved vs. a minimum-efficiency heat pump: $257

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 22, 2026. How we use the data.