3-ton central heat pump · 2-STAGE 18 SEER HP

Bryant 248TAN036**AA

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #160 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,163 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
19,600 BTU/h49% of its 47°F output
Excellent · beats 98%

A good fit if…

  • You want a choice of indoor units - 274 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandBryant
Outdoor unit model248TAN036**AA
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-38,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F37,200-39,000 BTU/h
Capacity at 17°F23,000-24,200 BTU/h
Capacity at 5°F17,500-19,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.78-2.48
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FG5ANBD60L at the standard test temperatures, in BTU/h:

Certified matchups274 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 274 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FG5ANBD60L-17.013.08.518,600215628939
PF5TNBD60L-17.013.08.518,600215628940
FT5ANBD60L-17.013.08.518,600215628938
FG5ANXC48L-16.512.58.118,700215628885
FT5AN(B,X)C48L-16.512.58.118,700215628884
PF5TNXC48L-16.512.58.118,700215628886
FT5BD4821X-16.513.08.118,400218695407
CAA**4321AM83*SB60080M21***16.012.08.519,100215637787
CAA**3721AM927TA66100V21***16.012.08.519,200215714848
CAA**3721AM82*SB66110V21***16.012.08.119,400215635684
CAA**3721AM83*SB48060M17***16.012.08.119,300215635714
CAA**3721AM935SB66100M21***16.012.08.119,400215636139
CAA**3721AM926TC66100V21***16.012.08.119,200215636370
CAA**4321AM82*SB66110V21***16.012.08.119,200215637714
CAA**4321AM83*SB48060M17***16.012.08.119,300215637761
CAA**4321AM935SB66100M21***16.012.08.119,100215638393
CAA**4321AM926TC66100V21***16.012.08.119,200215638622
CAA**4821AM83*SB60080M21***16.012.08.119,000215638881
CAA**4821AM926TC66100V21***16.012.08.119,100215639746
FT5BD3617X-16.012.58.118,300218695390
CVAMA4821XMA83*SB60080M21***16.012.58.017,500215619534
CVAMA4921XMA82*SB60090V21***16.012.58.017,900215619885
CVAMA4921XMA83*SB60080M21***16.012.58.017,700215619898
CVAMA4921XMA82*TB60090V21***16.012.58.017,900215619971
CVAMA4921XMA935CB66100C21***16.012.58.017,900215620001
CVAMA4921XMA926TC60100V21***16.012.58.017,900215620078
CVAVA3817XMA82*SB48090V17***16.012.58.017,600215621310
CVAVA3817XMA83*SB36040M17***16.012.58.017,600215621323
CVAVA3817XMA83*SB48060M17***16.012.58.017,600215621342
CVAVA3817XMA82*TB48090V17***16.012.58.017,600215621443
CAA**3721AM83*CB60080C21***16.012.08.019,200215721358
CAA**4321AM83*CB60080C21***16.012.08.019,200215721519
CAA**4821AM927TA66100V21***16.012.08.019,100215721593
CVAMA4921XMA927TA60100V21***16.012.58.017,900215716296
CVAVA3817XMA83*CB48060C17***16.012.08.017,500215716698
CVAVA3817XMA83*CB36040C17***16.012.08.017,600215716684
CVAMA4921XMA986TD60080C21***16.012.57.817,900215620042
CVAVA3817XMA88*TB48090C17***16.012.57.817,600215621403
CAA**4321AM927TA66100V21***15.512.08.519,200215715061
CAA**3717AM83*CA36040C17***15.511.78.118,900215635130
CAA**3721AM82*SB48090V17***15.511.78.119,300215635658
CAA**3717AM82*SB48090V17***15.512.08.118,900215635197
CAA**3717AM83*SB36040M17***15.512.08.118,800215635210
CAA**3721AM82*SB60090V21***15.512.08.119,300215635671
CAA**3721AM83*SB36040M17***15.512.08.119,300215635697
CAA**3721AM83*SB60080M21***15.512.08.119,100215635731
CAA**3721AM83*SB60100M21***15.512.08.119,400215635748
CAA**3721AM88*TB60070C21***15.511.78.119,400215635793
CAA**3721AM88*TB48090C17***15.511.78.119,400215635807
CAA**3721AM88*TB60090C21***15.512.08.119,300215635821
CAA**3721AM88*TB60110C21***15.512.08.119,300215635835
CAA**3721AM82*TB48090V17***15.511.78.119,300215635865
CAA**3721AM82*TB60090V21***15.512.08.119,300215635873
CAA**3721AM82*TB66110V21***15.511.78.119,500215635889
CAA**3721AM935CB60080C21***15.512.08.119,300215635919
CAA**3717AM83*SB48060M17***15.512.08.118,800215635229
CAA**3721AM987MC66100C21***15.512.08.119,300215636003
CAA**3721AM926SB60080V21***15.511.78.119,300215636043
CAA**3721AM926SB60100V21***15.511.78.119,400215636056
CAA**3721AM935CB66100C21***15.512.08.119,300215635933
Yearly running cost in 10 large cities$992-$2,820

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 248TAN036**AA?
The Bryant 248TAN036**AA is rated at up to 17.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 274 certified matchups SEER2 ranges from 15.2-17.0.
Is the Bryant 248TAN036**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Bryant 248TAN036**AA cost to run per year?
At its rated efficiency it costs about $992-$2,820 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,246 in Phoenix and $2,374 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 248TAN036**AA?
ENERGY STAR lists 274 certified combinations for this outdoor unit. The highest-rated ones use FG5ANBD60L, PF5TNBD60L, FT5ANBD60L.
What refrigerant does the Bryant 248TAN036**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,249/yrYou save $642/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 248TAN036**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,249
Current system, per year
$1,890
You save per year
$642
Payback
21.0 years
Net after 10 years
-$7,084

Cooling $741Heating $507Electricity used: 7,804 kWhSaved vs. a minimum-efficiency heat pump: $208

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.