HVAC Rated

3-ton central heat pump · 2-STAGE 18 SEER HP

Carrier 27TPA836A**30

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #162 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,163 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
19,600 BTU/h49% of its 47°F output
Excellent · beats 98%

A good fit if…

  • You want a choice of indoor units - 285 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandCarrier
Outdoor unit model27TPA836A**30
Series2-STAGE 18 SEER HP
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 4, 2024
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity33,800-38,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F37,200-39,000 BTU/h
Capacity at 17°F23,000-24,200 BTU/h
Capacity at 5°F17,500-19,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.78-2.48
ENERGY STAR cold climateNo
Heating output as it gets colder49% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5ANBD60L at the standard test temperatures, in BTU/h:

Certified matchups285 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 285 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FT5ANBD60L-17.013.08.518,600215628934
FG5ANBD60L-17.013.08.518,600215628935
FT5AN(B,X)C48L-16.512.58.118,700215628880
FG5ANXC48L-16.512.58.118,700215628881
FT5BD4821X-16.513.08.118,400218695405
CAA**4321AM58SU*B080M21**2016.012.08.519,100215637785
CAA**3721AM59TP7A100V21**2216.012.08.519,200215714846
CAA**3721AM58SP*B110V21**2216.012.08.119,400215635682
CAA**3721AM58SU*B060M17**1616.012.08.119,300215635712
CAA**3721AM59SU5B100M21**2216.012.08.119,400215636136
CAA**3721AM59TP6C100V21**2216.012.08.119,200215636367
CAA**4321AM58SP*B110V21**2216.012.08.119,200215637711
CAA**4321AM58SU*B060M17**1616.012.08.119,300215637758
CAA**4321AM59SU5B100M21**2216.012.08.119,100215638390
CAA**4321AM59TP6C100V21**2216.012.08.119,200215638618
CAA**4821AM58SU*B080M21**2016.012.08.119,000215638878
CAA**4821AM59TP6C100V21**2216.012.08.119,100215639744
FT5BD3617X-16.012.58.118,300218695388
CVAMA4821XMA58SU*B080M21**2016.012.58.017,500215619532
CVAMA4921XMA58SP*B090V21**2016.012.58.017,900215619883
CVAMA4921XMA58SU*B080M21**2016.012.58.017,700215619896
CVAMA4921XMA58TP*B090V21**2016.012.58.017,900215619969
CVAMA4921XMA59CU5B100C21**2216.012.58.017,900215619999
CVAMA4921XMA59TP6C100V21**2016.012.58.017,900215620074
CVAMA4921XMAGG96VTAB60100C**16.012.58.017,900215620075
CVAVA3817XMA58SP*B090V17**1616.012.58.017,600215621308
CVAVA3817XMA58SU*B040M17**1216.012.58.017,600215621321
CVAVA3817XMA58SU*B060M17**1616.012.58.017,600215621340
CVAVA3817XMA58TP*B090V17**1616.012.58.017,600215621441
CAA**3721AM58CU*B080C21**2016.012.08.019,200215721356
CAA**4321AM58CU*B080C21**2016.012.08.019,200215721517
CAA**4821AM59TP7A100V21**2216.012.08.019,100215721591
CVAMA4921XMA59TP7A100V21**2016.012.58.017,900215716294
CVAVA3817XMA58CU*B060C17**1616.012.08.017,500215716696
CVAVA3817XMA58CU*B040C17**1216.012.08.017,600215716682
CVAMA4921XMA59TN6C080C21**2016.012.57.817,900215620040
CVAVA3817XMA58TN*B090C17**1616.012.57.817,600215621401
CAA**4321AM59TP7A100V21**2215.512.08.519,200215715059
CAA**3717AM58CU*A040C17**1215.511.78.118,900215635128
CAA**3721AM58SP*B090V17**1615.511.78.119,300215635656
CAA**3717AM58SP*B090V17**1615.512.08.118,900215635195
CAA**3717AM58SU*B040M17**1215.512.08.118,800215635208
CAA**3721AM58SP*B090V21**2015.512.08.119,300215635669
CAA**3721AM58SU*B040M17**1215.512.08.119,300215635695
CAA**3721AM58SU*B080M21**2015.512.08.119,100215635729
CAA**3721AM58SU*B100M21**2015.512.08.119,400215635746
CAA**3721AM58TN*B070C21**2015.511.78.119,400215635791
CAA**3721AM58TN*B090C17**1615.511.78.119,400215635805
CAA**3721AM58TN*B090C21**2015.512.08.119,300215635819
CAA**3721AM58TN*B110C21**2015.512.08.119,300215635833
CAA**3721AM58TP*B090V17**1615.511.78.119,300215635863
CAA**3721AM58TP*B090V21**2015.512.08.119,300215635871
CAA**3721AM58TP*B110V21**2215.511.78.119,500215635887
CAA**3721AM59CU5B080C21**2015.512.08.119,300215635917
CAA**3717AM58SU*B060M17**1615.512.08.118,800215635227
CAA**3721AM59MN7C100C21**2215.512.08.119,300215636001
CAA**3721AM59SP6B080V21**2015.511.78.119,300215636041
CAA**3721AM59SP6B100V21**2015.511.78.119,400215636054
CAA**3721AM59CU5B100C21**2215.512.08.119,300215635931
CAA**3721AM59MN7C080C21**2015.512.08.119,300215635987
Yearly running cost in 10 large cities$992-$2,820

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Carrier 27TPA836A**30?
The Carrier 27TPA836A**30 is rated at up to 17.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 285 certified matchups SEER2 ranges from 15.2-17.0.
Is the Carrier 27TPA836A**30 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Carrier 27TPA836A**30 cost to run per year?
At its rated efficiency it costs about $992-$2,820 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,246 in Phoenix and $2,374 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Carrier 27TPA836A**30?
ENERGY STAR lists 285 certified combinations for this outdoor unit. The highest-rated ones use FT5ANBD60L, FG5ANBD60L, FT5AN(B,X)C48L.
What refrigerant does the Carrier 27TPA836A**30 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,249/yrYou save $642/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27TPA836A**30
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,249
Current system, per year
$1,890
You save per year
$642
Payback
21.0 years
Net after 10 years
-$7,084

Cooling $741Heating $507Electricity used: 7,804 kWhSaved vs. a minimum-efficiency heat pump: $208

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.