HVAC Rated

2-ton central heat pump · HSA14 Series

Century HSA1424S1-**A

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #281 of 331 2 ton central heat pumps for cooling efficiency, and costs about $739 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
13.8 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
11,600 BTU/h51% of its 47°F output
Very good · beats 71%

A good fit if…

  • You want a choice of indoor units - 98 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandCentury
Also sold asComfort-Aire
Outdoor unit modelHSA1424S1-**A
SeriesHSA14 Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.0-13.8
Cooling capacity22,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F20,400-23,000 BTU/h
Capacity at 17°F12,900-14,700 BTU/h
Capacity at 5°F10,600-11,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.98-2.18
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with HMA30CX1*- at the standard test temperatures, in BTU/h:

Certified matchups98 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 98 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
HMA30CX1*--16.013.88.111,300217662734
HMA30CX1*--16.013.88.111,300217662728
7EH30BX-**+TDRGUH80C090B4MP*15.513.48.111,000216372585
7EH24BX-**+TDRGUH80C070B3MP*15.513.28.110,600216372681
7EH24BX-**+TDRGUH80C090B4MP*15.513.48.110,700216372682
7E[C,U]30BX-**+TDRGUH80C090B4MP*15.513.28.111,400216372569
HMA30VX1*--15.513.68.111,600216372554
HMA30VX1*--15.513.68.111,600216372660
7EH24BX-**+TDRGUH80C070B3MP*15.513.28.110,600216372575
7EH24BX-**+TDRGUH80C090B4MP*15.513.48.110,700216372576
7EH30BX-**+TDRGUH80C090B4MP*15.513.48.111,000216372691
7E[C,U]30BX-**+TDRGUH80C090B4MP*15.513.28.111,400216372675
7EH24BX-**+TDRGUH97T070B3MP15.513.28.110,600216801503
7EH24BX-**+TDRGUH97T070B3MP15.513.28.110,600216801533
7EH30BX-**+TDRGUH80C070B3MP*15.513.48.010,900216372584
7E[C,U]30BX-**+TDRGUH80C070B3MP*15.513.28.011,300216372568
7E[C,U]24BX-**+TDRGUH80C090B4MP*15.513.28.010,800216372665
7EH30BX-**+TDRGUH80C070B3MP*15.513.48.010,900216372690
7E[C,U]24BX-**+TDRGUH80C090B4MP*15.513.28.010,800216372559
7E[C,U]30AX-**+TDRGUH80C070A3MP*15.513.28.011,300216372672
7E[C,U]30BX-**+TDRGUH80C070B3MP*15.513.28.011,300216372674
7EH30BX-**+TDRGUH92C070B3MP*15.513.28.011,100216372693
7EH30BX-**+TDRGUH96C070B3MP*15.513.28.011,100216372694
7EH30BX-**+TDRGUH92C070B3MP*15.513.28.011,100216372587
7EH30BX-**+TDRGUH96C070B3MP*15.513.28.011,100216372588
7E[C,U]30AX-**+TDRGUH80C070A3MP*15.513.28.011,300216372566
7E[C,U]30BX-**+TDRGUH97T045B3MP*15.513.08.011,300216498816
7E[C,U]30BX-**+TDRGUH97T045B3MP*15.513.08.011,300216498785
7E[C,U]30BX-**+TDRGUH97T070B3MP15.513.28.011,300216801502
7E[C,U]30BX-**+TDRGUH97T070B3MP15.513.28.011,300216801532
7E[C,U]24AX-**+TDRGUH80C070A3MP*15.513.07.810,800216372663
7E[C,U]24BX-**+TDRGUH80C070B3MP*15.513.27.810,800216372664
7E[C,U]24AX-**+TDRGUH80C070A3MP*15.513.07.810,800216372557
7E[C,U]24BX-**+TDRGUH80C070B3MP*15.513.27.810,800216372558
7E[C,U]30AX-**+TDRGUH80C045A3MP*15.513.27.811,200216372671
7E[C,U]30AX-**+TDRGUH80C045A3MP*15.513.27.811,200216372565
7E[C,U]24BX-**+TDRGUH97T045B3MP*15.513.07.810,800216498815
7E[C,U]24BX-**+TDRGUH97T045B3MP*15.513.07.810,800216498784
7EH30BX-**+TDRGUH97T045B3MP*15.513.27.810,900216498787
7EH30BX-**+TDRGUH97T045B3MP*15.513.27.810,900216498818
7ED30/36BX-**+TDRGDD80C090B4MP*15.213.28.211,300216372695
7ED30/36CX-**+TDRGDD92C090C4MP*15.213.08.211,400216372696
7ED30/36CX-**+TDRGDD96C090C4MP*15.213.28.211,300216372697
7ED30/36BX-**+TDRGDD80C090B4MP*15.213.28.211,300216372589
7ED30/36CX-**+TDRGDD92C090C4MP*15.213.08.211,400216372590
7ED30/36CX-**+TDRGDD96C090C4MP*15.213.28.211,300216372591
7E[C,U]30BX-**+TDRGUH96C070B3MP*15.213.08.111,500216372678
7EH24BX-**+TDRGUH96C070B3MP*15.213.08.110,800216372684
7E[C,U]30BX-**+TDRGUH92C070B3MP*15.213.08.111,500216372571
7E[C,U]30BX-**+TDRGUH96C070B3MP*15.213.08.111,500216372572
7EH24BX-**+TDRGUH92C070B3MP*15.213.08.110,800216372577
7EH24BX-**+TDRGUH96C070B3MP*15.213.08.110,800216372578
7E[C,U]30BX-**+TDRGUH92C070B3MP*15.213.08.111,500216372677
7EH24BX-**+TDRGUH92C070B3MP*15.213.08.110,800216372683
7EH30AX-**+TDRGUH80X060A3MP*15.212.88.011,200216372580
7EH30AX-**+TDRGUH80C070A3MP*15.213.28.011,000216372582
7EH30BX-**+TDRGUH80X080B4MP*15.213.28.011,100216372583
7EH30BX-**+TDRGUH92C045B3MP*15.213.08.011,200216372586
7E[C,U]30BX-**+TDRGUH92C045B3MP*15.212.88.011,600216372676
7EH24BX-**+TDRGUH80X080B4MP*15.213.08.010,800216372680
Yearly running cost in 10 large cities$703-$1,731

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Century HSA1424S1-**A?
The Century HSA1424S1-**A is rated at up to 16.0 SEER2 and 13.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 98 certified matchups SEER2 ranges from 15.2-16.0.
Is the Century HSA1424S1-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Century HSA1424S1-**A cost to run per year?
At its rated efficiency it costs about $703-$1,731 a year in electricity in large U.S. cities, depending on climate and local rates - for example $846 in Phoenix and $1,431 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Century HSA1424S1-**A?
ENERGY STAR lists 98 certified combinations for this outdoor unit. The highest-rated ones use HMA30CX1*-, 7EH30BX-**+TDR, 7EH24BX-**+TDR.
What refrigerant does the Century HSA1424S1-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $828/yrYou save $376/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Century HSA1424S1-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$828
Current system, per year
$1,205
You save per year
$376
Payback
23.9 years
Net after 10 years
-$5,237

Cooling $528Heating $300Electricity used: 5,178 kWhSaved vs. a minimum-efficiency heat pump: $91

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.