HVAC Rated

2-ton central heat pump · 7HP14F Series

Concord 7HP14F24P-**A

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #282 of 331 2 ton central heat pumps for cooling efficiency, and costs about $736 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
13.8 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
11,600 BTU/h51% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 462 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandConcord
Also sold asDucane, ALLIED, Breeze33
Outdoor unit model7HP14F24P-**A
Series7HP14F Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 1, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.0-13.8
Cooling capacity22,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F20,400-23,000 BTU/h
Capacity at 17°F12,900-14,700 BTU/h
Capacity at 5°F10,500-11,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 7AH1AE30PX- at the standard test temperatures, in BTU/h:

Certified matchups462 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 462 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
7AH1AE30PX--16.013.88.111,300215710691
7AH1AE30PX--16.013.88.111,300215710818
7AH1AE30PX--16.013.88.111,300215710945
7AH1AE30PX--16.013.88.111,300215792358
7AH2AE30PX--15.513.28.211,400215710950
7AH2AV30PXC-15.513.08.211,400215710952
7AH2AE30PX--15.513.28.211,400215710823
7AH2AV30PXC-15.513.08.211,400215710825
7AH2AV30PXC-15.513.08.211,400215710698
7AH2AE30PX--15.513.28.211,400215710696
7AH2AE30PX--15.513.28.211,400215792363
7AH2AV30PXC-15.513.08.211,400215792365
7EH24BX-**+TDR80G1UH090BE16L*15.513.48.110,700215710898
7EH30BX-**+TDR80G1UH090BE16*15.513.48.111,000215710923
7EH30BX-**+TDR80G1UH090BE16L*15.513.48.111,000215710924
7AH1AV30PX--15.513.68.111,600215710948
7AH1AV30PX--15.513.68.111,600215710694
7AH1AV30PX--15.513.68.111,600215710821
7E[C,U]30BX-**+TDR80G1UH090BE16*15.513.28.111,400215710744
7E[C,U]30BX-**+TDR80G1UH090BE16L*15.513.28.111,400215710745
7EH24BX-**+TDR80G2UH090BE16*15.513.28.110,800215711018
7EH24BX-**+TDR80G1UH070BE12*15.513.28.110,600215711022
7EH24BX-**+TDR80G1UH070BE12L*15.513.28.110,600215711023
7EH24BX-**+TDR80G1UH090BE16*15.513.48.110,700215711024
7EH24BX-**+TDR80G1UH090BE16L*15.513.48.110,700215711025
7EH24BX-**+TDR80G2UH090BE16*15.513.28.110,800215710764
7EH24BX-**+TDR80G2UH090BE16L*15.513.28.110,700215710765
7EH24BX-**+TDR80G1UH070BE12*15.513.28.110,600215710768
7EH24BX-**+TDR80G1UH070BE12L*15.513.28.110,600215710769
7E[C,U]30BX-**+TDR80G2UH090BE16*15.513.28.111,400215710992
7E[C,U]30BX-**+TDR80G2UH090BE16L*15.513.28.111,400215710993
7E[C,U]30BX-**+TDR80G2UH090BE16*15.513.28.111,400215710865
7EH30BX-**+TDR80G1UH090BE16*15.513.48.111,000215710796
7EH30BX-**+TDR80G1UH090BE16L*15.513.48.111,000215710797
7EH30BX-**+TDR80G1UH090BE16*15.513.48.111,000215711050
7EH30BX-**+TDR80G1UH090BE16L*15.513.48.111,000215711051
7E[C,U]30BX-**+TDR80G2UH090BE16*15.513.28.111,400215710738
7E[C,U]30BX-**+TDR80G1UH090BE16*15.513.28.111,400215710998
7E[C,U]30BX-**+TDR80G1UH090BE16L*15.513.28.111,400215710999
7EH24BX-**+TDR80G1UH090BE16L*15.513.48.110,700215710771
7EH24BX-**+TDR80G2UH090BE16L*15.513.28.110,700215710892
7EH24BX-**+TDR80G1UH070BE12*15.513.28.110,600215710895
7EH24BX-**+TDR80G1UH090BE16*15.513.48.110,700215710897
7E[C,U]30BX-**+TDR80G2UH090BE16L*15.513.28.111,400215710866
7E[C,U]30BX-**+TDR80G1UH090BE16*15.513.28.111,400215710871
7E[C,U]30BX-**+TDR80G1UH090BE16L*15.513.28.111,400215710872
7EH24BX-**+TDR80G2UH090BE16*15.513.28.110,800215710891
7EH24BX-**+TDR80G1UH070BE12L*15.513.28.110,600215710896
7EH24BX-**+TDR80G2UH090BE16L*15.513.28.110,700215711019
7EH24BX-**+TDR80G1UH090BE16*15.513.48.110,700215710770
7E[C,U]30BX-**+TDR80G2UH090BE16L*15.513.28.111,400215710739
7E[C,U]30BX-**+TDR80G1UH090BE16*15.513.28.111,400215792411
7E[C,U]30BX-**+TDR80G2UH090BE16*15.513.28.111,400215792405
7EH30BX-**+TDR80G1UH090BE16*15.513.48.111,000215792463
7EH30BX-**+TDR80G1UH090BE16L*15.513.48.111,000215792464
7EH24BX-**+TDR80G1UH070BE12*15.513.28.110,600215792435
7EH24BX-**+TDR80G1UH070BE12L*15.513.28.110,600215792436
7EH24BX-**+TDR80G1UH090BE16*15.513.48.110,700215792437
7EH24BX-**+TDR80G1UH090BE16L*15.513.48.110,700215792438
7AH1AV30PX--15.513.68.111,600215792361
Yearly running cost in 10 large cities$697-$1,728

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Concord 7HP14F24P-**A?
The Concord 7HP14F24P-**A is rated at up to 16.0 SEER2 and 13.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 462 certified matchups SEER2 ranges from 15.2-16.0.
Is the Concord 7HP14F24P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Concord 7HP14F24P-**A cost to run per year?
At its rated efficiency it costs about $697-$1,728 a year in electricity in large U.S. cities, depending on climate and local rates - for example $840 in Phoenix and $1,429 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Concord 7HP14F24P-**A?
ENERGY STAR lists 462 certified combinations for this outdoor unit. The highest-rated ones use 7AH1AE30PX-, 7AH2AE30PX-, 7AH2AV30PXC.
What refrigerant does the Concord 7HP14F24P-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $824/yrYou save $374/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Concord 7HP14F24P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$824
Current system, per year
$1,198
You save per year
$374
Payback
24.1 years
Net after 10 years
-$5,264

Cooling $524Heating $300Electricity used: 5,151 kWhSaved vs. a minimum-efficiency heat pump: $90

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.