HVAC Rated

2-ton central heat pump · NS16H Series

GE NS16H24SA5-**A

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #283 of 331 2 ton central heat pumps for cooling efficiency, and costs about $736 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
13.8 Cooling efficiency on a 95°F day
Excellent · beats 97%
Heat at 5°F
11,600 BTU/h51% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 99 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandGE
Outdoor unit modelNS16H24SA5-**A
SeriesNS16H Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.0-13.8
Cooling capacity22,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F20,400-23,000 BTU/h
Capacity at 17°F12,900-14,700 BTU/h
Capacity at 5°F10,500-11,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM30E1TA5*- at the standard test temperatures, in BTU/h:

Certified matchups99 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 99 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
NAM30E1TA5*--16.013.88.111,300216497348
NAM30V2TA5*--15.513.08.211,400216497353
NCU[C,U]30BT5*-**+TDRNF80U090S4B*15.513.28.111,400216497393
NAM30V1TA5*--15.513.68.111,600216497351
NCHC24BT5*-**+TDRNF80U090T4B*15.513.28.110,800216497414
NCHC24BT5*-**+TDRNF80U070S3B*15.513.28.110,600216497415
NCHC24BT5*-**+TDRNF80L070S3B*15.513.28.110,600216497416
NCHC24BT5*-**+TDRNF80U090S4B*15.513.48.110,700216497417
NCHC24BT5*-**+TDRNF80L090S4B*15.513.48.110,700216497418
NCHC30BT5*-**+TDRNF80U090S4B*15.513.48.111,000216497441
NCHC30BT5*-**+TDRNF80L090S4B*15.513.48.111,000216497442
NCU[C,U]30BT5*-**+TDRNF80U090T4B*15.513.28.111,400216497390
NCU[C,U]30BT5*-**+TDRNF80L090S4B*15.513.28.111,400216497394
NCHC24BT5*-**+TDRNF97U070V3B*15.513.28.110,600217052166
NCU[C,U]30BT5*-**+TDRNF97U045V3B*15.513.08.011,300216497397
NCU[C,U]30BT5*-**+TDRNF98U070M3B*15.513.08.011,300216497401
NCU[C,U]30BT5*-**+TDRNF80L070S3B*15.513.28.011,300216497392
NCU[C,U]30BT5*-**+TDRNF80U070S3B*15.513.28.011,300216497391
NCU[C,U]30AT5*-**+TDRNF80U045T3A*15.513.28.011,200216497380
NCHC30BT5*-**+TDRNF80U090T4B*15.513.48.011,000216497438
NCHC30BT5*-**+TDRNF80U070S3B*15.513.48.010,900216497439
NCHC30BT5*-**+TDRNF80L070S3B*15.513.48.010,900216497440
NCHC30BT5*-**+TDRNF96U070S3B*15.513.28.011,100216497444
NCU[C,U]30AT5*-**+TDRNF80U070S3A*15.513.28.011,300216497384
NCU[C,U]30AT5*-**+TDRNF80L070S3A*15.513.28.011,300216497385
NCU[C,U]30AT5*-**+TDRNF80X060V3A*15.513.28.011,300216497386
NCU[C,U]24BT5*-**+TDRNF80U090T4B*15.513.28.010,900216497366
NCU[C,U]24BT5*-**+TDRNF80U090S4B*15.513.28.010,800216497369
NCU[C,U]24BT5*-**+TDRNF80L090S4B*15.513.28.010,800216497370
NCU[C,U]30AT5*-**+TDRNF80U070V3A*15.513.08.011,400217052160
NCU[C,U]30BT5*-**+TDRNF97U070V3B*15.513.28.011,300217052162
NCHC24AT5*-**+TDRNF80U045T3A*15.513.27.810,500216497404
NCHC30AT5*-**+TDRNF80U045T3A*15.513.27.810,900216497428
NCU[C,U]24AT5*-**+TDRNF80U070S3A*15.513.07.810,800216497360
NCU[C,U]24AT5*-**+TDRNF80L045S3A*15.513.27.810,600216497359
NCU[C,U]24AT5*-**+TDRNF80L070S3A*15.513.07.810,800216497361
NCU[C,U]24AT5*-**+TDRNF80X060V3A*15.513.07.810,800216497362
NCHC30BT5*-**+TDRNF97U045V3B*15.513.27.810,900216497445
NCHC30BT5*-**+TDRNF97X060V3B*15.513.27.810,900216497448
NCU[C,U]24AT5*-**+TDRNF80U045T3A*15.513.27.810,700216497356
NCU[C,U]24BT5*-**+TDRNF97U045V3B*15.513.07.810,800216497373
NCU[C,U]24BT5*-**+TDRNF98U070M3B*15.513.07.810,800216497377
NCU[C,U]30AT5*-**+TDRNF80U045S3A*15.513.27.811,200216497382
NCU[C,U]30AT5*-**+TDRNF80L045S3A*15.513.27.811,200216497383
NCU[C,U]24BT5*-**+TDRNF80U070S3B*15.513.27.810,800216497367
NCU[C,U]24BT5*-**+TDRNF80L070S3B*15.513.27.810,800216497368
NCHC30BT5*-**+TDRNF98U070M3B*15.513.27.810,900216497449
NCDC36CT5*-**+TDRNF96D090S4C*15.213.28.211,300216497457
NAM24V2TA5*--15.212.88.211,200216497352
NCDC36BT5*-**+TDRNF80D090T4B*15.213.08.211,400216497455
NCDC36BT5*-**+TDRNF80D090S4B*15.213.28.211,300216497456
NCDC36CT5*-**+TDRNF97D090T4C*15.213.28.211,300218159779
NCU[C,U]30BT5*-**+TDRNF96U070S3B*15.213.08.111,500216497396
NCHC24BT5*-**+TDRNF98U070M3B*15.212.88.110,700216497425
NCHC24BT5*-**+TDRNF96U070S3B*15.213.08.110,800216497420
NCU[C,U]30BT5*-**+TDRNF97X060V3B*15.213.08.011,300216497400
NCHC24BT5*-**+TDRNF97U045V3B*15.213.08.010,600216497421
NCHC30AT5*-**+TDRNF80X040S3A*15.212.88.011,200216497426
NCHC30AT5*-**+TDRNF80X060S3A*15.212.88.011,200216497427
NCHC30AT5*-**+TDRNF80U070T3A*15.212.88.011,300216497429
Yearly running cost in 10 large cities$697-$1,728

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the GE NS16H24SA5-**A?
The GE NS16H24SA5-**A is rated at up to 16.0 SEER2 and 13.8 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 99 certified matchups SEER2 ranges from 15.2-16.0.
Is the GE NS16H24SA5-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the GE NS16H24SA5-**A cost to run per year?
At its rated efficiency it costs about $697-$1,728 a year in electricity in large U.S. cities, depending on climate and local rates - for example $840 in Phoenix and $1,429 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the GE NS16H24SA5-**A?
ENERGY STAR lists 99 certified combinations for this outdoor unit. The highest-rated ones use NAM30E1TA5*-, NAM30V2TA5*-, NCU[C,U]30BT5*-**+TDR.
What refrigerant does the GE NS16H24SA5-**A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $824/yrYou save $374/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE NS16H24SA5-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$824
Current system, per year
$1,198
You save per year
$374
Payback
24.1 years
Net after 10 years
-$5,264

Cooling $524Heating $300Electricity used: 5,151 kWhSaved vs. a minimum-efficiency heat pump: $90

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.