HVAC Rated

2-ton central heat pump · LX SERIES

Coleman XH524E2S11

Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #287 of 331 2 ton central heat pumps for cooling efficiency, and costs about $760 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
12,700 BTU/h54% of its 47°F output
Very good · beats 85%

A good fit if…

  • You want a choice of indoor units - 290 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandColeman
Also sold asLuxaire, Fraser-Johnston, CHAMPION HEATING AND COOLING, Kenmore, Johnson Controls
Outdoor unit modelXH524E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 9, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity23,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F22,200-23,600 BTU/h
Capacity at 17°F14,200-15,400 BTU/h
Capacity at 5°F11,200-12,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.28
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTU30B5XCS1+TXV at the standard test temperatures, in BTU/h:

Certified matchups290 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 290 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217445035
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217445036
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444724
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217444725
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444726
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444788
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444786
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217444787
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444848
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217444849
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444850
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444910
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217444911
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444912
CTM30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444974
CTU30B5XCS1+TXVZ8VT080B12SMPC116.012.08.112,400217444973
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217444972
CTF30B5ACS1Z8VT080B12SMPC116.012.08.112,400217445034
CTM30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524885
CTM30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524884
CTM30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524883
CTM30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524882
CTU30B5XCS2+TXVZ8VT080B12SMPC116.012.08.112,400218524753
CTU30B5XCS2+TXVZ8VT080B12SMPC116.012.08.112,400218524752
CTU30B5XCS2+TXVZ8VT080B12SMPC116.012.08.112,400218524751
CTU30B5XCS2+TXVZ8VT080B12SMPC116.012.08.112,400218524750
CTF30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524749
CTF30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524748
CTF30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524747
CTF30B5ACS2Z8VT080B12SMPC116.012.08.112,400218524746
CTM30B5ACS2Z8VT080B12SMPC116.012.08.112,400218600490
CTU30B5XCS2+TXVZ8VT080B12SMPC116.012.08.112,400218600473
CTF30B5ACS2Z8VT080B12SMPC116.012.08.112,400218600472
CTM30B5ACS1+JMC12B2SN1-15.212.08.112,300214427635
CTM30B5ACS1+JMC12B2SN1-15.212.08.112,300214427636
CTM30B5ACS1+JMC12B2SN1-15.212.08.112,300214427638
CTM30B5ACS1+JMC12B2SN1-15.212.08.112,300214427637
CTM30B5ACS1+JMC12B2SN1-15.212.08.112,300214427639
CTM30B5ACS1+JME12B2SN1-15.212.08.112,300214428078
CTM30B5ACS1+JME12B2SN1-15.212.08.112,300214428079
CTM30B5ACS1+JME12B2SN1-15.212.08.112,300214428081
CTM30B5ACS1+JME12B2SN1-15.212.08.112,300214428080
CTM30B5ACS1+JME12B2SN1-15.212.08.112,300214428082
CTM30B5ACS1+JME08B2SN1-15.212.08.112,200214429192
CTM30B5ACS1+JME08B2SN1-15.212.08.112,200214429191
CTM30B5ACS1+JME08B2SN1-15.212.08.112,200214429193
CTM30B5ACS1+JME08B2SN1-15.212.08.112,200214429194
CTM30B5ACS1+JME08B2SN1-15.212.08.112,200214429195
CTM30B5ACS1+JMVT12BC2N1-15.212.08.112,300214431873
CTM30B5ACS1+JMVT12BC2N1-15.212.08.112,300214431905
CTM30B5ACS1+JMVT12BC2N1-15.212.08.112,300214431966
CTM30B5ACS1+JMVT12BC2N1-15.212.08.112,300214431997
CTM30B5ACS1+JMVT12BC2N1-15.212.08.112,300214432028
CTM30B5ACS1Z8ES080B12SMPS115.212.08.112,400214605544
CTM30B5ACS1Z8ES080B12SMPS115.212.08.112,400214605545
CTM30B5ACS1Z8ES080B12SMPS115.212.08.112,400214605546
CTM30B5ACS1Z8ES080B12SMPS115.212.08.112,400214605547
CTM30B5ACS1Z8ES080B12SMPS115.212.08.112,400214605548
CTM30B5ACS1Z8ES100B12SMPS115.212.08.112,500214605844
CTM30B5ACS1Z8ES100B12SMPS115.212.08.112,500214605845
Yearly running cost in 10 large cities$704-$1,798

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman XH524E2S11?
The Coleman XH524E2S11 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 290 certified matchups SEER2 ranges from 15.2-16.0.
Is the Coleman XH524E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Coleman XH524E2S11 cost to run per year?
At its rated efficiency it costs about $704-$1,798 a year in electricity in large U.S. cities, depending on climate and local rates - for example $856 in Phoenix and $1,494 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman XH524E2S11?
ENERGY STAR lists 290 certified combinations for this outdoor unit. The highest-rated ones use CTU30B5XCS1+TXV, CTM30B5ACS1, CTF30B5ACS1.
What refrigerant does the Coleman XH524E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $843/yrYou save $375/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman XH524E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$843
Current system, per year
$1,218
You save per year
$375
Payback
24.0 years
Net after 10 years
-$5,254

Cooling $528Heating $315Electricity used: 5,270 kWhSaved vs. a minimum-efficiency heat pump: $88

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.