HVAC Rated

2.5-ton central heat pump · SOFTSOUND DELUXE 18 VS HP 2-STAGE

Comfortmaker CVH837GKA2*+TSTAT

Average cooling efficiency and below average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #51 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $1,267 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
24,400 BTU/h51% of its 47°F output
Below average · beats 31%

A good fit if…

  • You want a choice of indoor units - 195 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandComfortmaker
Also sold asDay & Night, Keeprite
Outdoor unit modelCVH837GKA2*+TSTAT
SeriesSOFTSOUND DELUXE 18 VS HP 2-STAGE
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 11, 2021
Last certifiedMay 15, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 17.0-18.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity31,600-33,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F46,000-48,000 BTU/h
Capacity at 17°F30,200-31,000 BTU/h
Capacity at 5°F24,000-24,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-1.98
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EN(A,D,W)4X60L24 at the standard test temperatures, in BTU/h:

Certified matchups195 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 195 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EN(A,D,W)4X60L24*80VSL0902420A*18.012.08.124,200210464996
EN(A,D,W)4X60L24*80VSL0902420A*18.012.08.124,200210464997
EN(A,D,W)4X60L24*80VSL0902420A*18.012.08.124,200210464995
EN(A,D,W)4X60L24*96VTN1002122A*18.012.08.124,000210464942
EN(A,D,W)4X60L24*96VTN1002122A*18.012.08.124,000210464941
EN(A,D,W)4X60L24*96VTN1002122A*18.012.08.124,000210464940
EA*4X61L24A*96VSN1002120A*18.011.78.124,200210461741
EA*4X61L21A*80VTL0902120A*18.011.78.124,400210461432
EA*4X61L24A*96VSN1202422A*18.011.78.124,200210461752
EA*4X61L24A*96VSN1202422A*18.011.78.124,200210461751
EA*4X61L24A*96VSN1002120A*18.011.78.124,200210461740
EA*4X61L24A*96VSN1002120A*18.011.78.124,200210461742
EA*4X60L24A*96VTN1002122A*18.011.78.124,200210460985
EA*4X60L24A*96VTN1002122A*18.011.78.124,200210460986
EA*4X61L21A*80VTL0902120A*18.011.78.124,400210461431
EA*4X60L24A*96VTN1002122A*18.011.78.124,200210460984
EA*4X61L21A*80VSL0902120A*18.011.78.124,400210461417
EA*4X61L21A*80VSL0902120A*18.011.78.124,400210461419
EA*4X61L21A*96VTN1002122A*18.011.78.124,200210461330
EA*4X61L21A*96VTN1002122A*18.011.78.124,200210461329
EA*4X61L21A*80VSL0902120A*18.011.78.124,400210461418
EA*4X61L24A*96VTN1202422A*18.011.78.124,200210461856
EA*4X61L24A*96VTN0802120A*18.011.78.124,400210461965
EA*4X61L24A*80VTL0902120A*18.011.78.124,400210461841
EA*4X61L21A*80VTL0902120A*18.011.78.124,400210461430
EA*4X61L21A*96VTN1002122A*18.011.78.124,200210461331
EA*4X61L24A*96VTN1002120A*18.011.78.124,400210461977
EA*4X61L24A*96VTN1002120A*18.011.78.124,400210461976
EA*4X61L24A*96VTN0802120A*18.011.78.124,400210461966
EA*4X61L24A*96VTN1002120A*18.011.78.124,400210461975
EA*4X61L24A*96VTN0802120A*18.011.78.124,400210461964
EA*4X61L24A*80VSL0902120A*18.011.78.124,400210461808
EA*4X61L24A*96VTN1202422A*18.011.78.124,200210461855
EA*4X61L24A*80VSL0902120A*18.011.78.124,400210461809
EA*4X61L24A*96VTN1202422A*18.011.78.124,200210461854
EA*4X61L24A*80VTL0902120A*18.011.78.124,400210461842
EA*4X61L24A*80VTL0902120A*18.011.78.124,400210461840
EA*4X61L24A*80VSL0902120A*18.011.78.124,400210461807
EA*4X61L24A*96VTN1002122A*18.011.78.124,200210461765
EA*4X61L24A*96VTN1002122A*18.011.78.124,200210461764
EA*4X61L24A*96VTN1002122A*18.011.78.124,200210461763
EA*4X61L24A*96VSN1202422A*18.011.78.124,200210461753
EA*4X43L21A*96VTN1002122A*17.511.78.524,400210459742
EA*4X43L21A*96VTN1002122A*17.511.78.524,400210459740
EA*4X37L21A*96VTN1002122A*17.511.78.524,400210458485
EA*4X37L21A*96VTN1002122A*17.511.78.524,400210458484
EA*4X43L21A*96VTN1002122A*17.511.78.524,400210459741
EA*4X37L21A*96VTN1002122A*17.511.78.524,400210458483
EA*4X61L24A*80VSL1102422A*17.511.78.524,000210461831
EA*4X61L24A*80VSL1102422A*17.511.78.524,000210461830
EA*4X61L24A*80VSL1102422A*17.511.78.524,000210461829
EN(A,D,W)4X60L24*80VSL0902120A*17.512.08.124,000210464984
EN(A,D,W)4X60L24*80VSL0902120A*17.512.08.124,000210464985
EN(A,D,W)4X60L24*80VSL0902120A*17.512.08.124,000210464986
EN(A,D)4X48L24*80VSL1102422A*17.512.08.124,200210464685
EN(A,D)4X48L24*80VSL1102422A*17.512.08.124,200210464684
EN(A,D)4X48L24*80VSL1102422A*17.512.08.124,200210464683
EN(A,D)4X48L24*96VTN1002122A*17.512.08.124,200210464617
EN(A,D)4X48L24*96VTN1002122A*17.512.08.124,200210464619
EN(A,D)4X48L24*96VTN1002122A*17.512.08.124,200210464618
Yearly running cost in 10 large cities$856-$3,254

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfortmaker CVH837GKA2*+TSTAT?
The Comfortmaker CVH837GKA2*+TSTAT is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 195 certified matchups SEER2 ranges from 17.0-18.0.
Is the Comfortmaker CVH837GKA2*+TSTAT good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Comfortmaker CVH837GKA2*+TSTAT cost to run per year?
At its rated efficiency it costs about $856-$3,254 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,189 in Phoenix and $2,822 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfortmaker CVH837GKA2*+TSTAT?
ENERGY STAR lists 195 certified combinations for this outdoor unit. The highest-rated ones use EN(A,D,W)4X60L24, EA*4X61L24A, EA*4X61L21A.
What refrigerant does the Comfortmaker CVH837GKA2*+TSTAT use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,249/yrYou save $653/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfortmaker CVH837GKA2*+TSTAT
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,249
Current system, per year
$1,902
You save per year
$653
Payback
18.4 years
Net after 10 years
-$5,465

Cooling $630Heating $619Electricity used: 7,806 kWhSaved vs. a minimum-efficiency heat pump: $245

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 15, 2025. How we use the data.