HVAC Rated

2.5-ton central heat pump · EVOLUTION V Heat Pump 2-STAGE

Bryant 288BNV037*0**B*+TSTAT

Average cooling efficiency and below average heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #49 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $1,267 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
24,400 BTU/h51% of its 47°F output
Below average · beats 31%

A good fit if…

  • You want a choice of indoor units - 71 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2.5 ton, R-410A
General
BrandBryant
Outdoor unit model288BNV037*0**B*+TSTAT
SeriesEVOLUTION V Heat Pump 2-STAGE
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 11, 2021
Last certifiedMay 15, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 17.0-18.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity31,600-33,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F46,000-48,000 BTU/h
Capacity at 17°F30,200-31,000 BTU/h
Capacity at 5°F24,000-24,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-1.98
ENERGY STAR cold climateNo
Heating output as it gets colder51% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CNPV*6024AL at the standard test temperatures, in BTU/h:

Certified matchups71 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 71 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CNPV*6024AL82*SA60090V24***18.012.08.124,200210464990
CNPV*6024AL82*TA66135V24***18.012.08.124,000210465023
CNPV*6024AL926TB66100V21***18.012.08.124,000210464935
CAP**6124AL926TB66100V21***18.011.78.124,200210461758
CAP**6124AL926SA66120V24***18.011.78.124,200210461746
CAP**6124AL926SA60100V21***18.011.78.124,200210461735
CAP**6121AL82*TA60090V21***18.011.78.124,400210461425
CAP**6121AL82*SA60090V21***18.011.78.124,400210461412
CAP**6121AL926TB66100V21***18.011.78.124,200210461324
CAP**6121AL82*TA48090V17***18.011.78.124,200210461423
CAP**6124AL926TB60100V21***18.011.78.124,400210461970
CAP**6124AL926TB60080V21***18.011.78.124,400210461959
CAP**6124AL926TB66120V24***18.011.78.124,200210461849
CAP**6124AL82*TA66135V24***18.011.78.124,200210461846
CAP**6124AL82*TA60090V21***18.011.78.124,400210461835
CAP**6124AL82*SA60090V21***18.011.78.124,400210461802
CAP**6024AL926TB66100V21***18.011.78.124,200210460979
CAP**6124AL82*SA66110V24***17.511.78.524,000210461824
CAP**4321AL926TB66100V21***17.511.78.524,400210459735
CAP**3721AL926TB66100V21***17.511.78.524,400210458478
CNPV*6024AL82*SA60090V21***17.512.08.124,000210464979
CNPV*4824AL82*SA66110V24***17.512.08.124,200210464678
CNPV*4824AL926TB66100V21***17.512.08.124,200210464612
CNPV*4821AL926TB66100V21***17.512.08.124,200210464167
CNPV*6024AL82*SA66110V24***17.512.08.124,000210465001
CNPV*6024AL82*TA60090V21***17.512.08.124,000210465012
CNPV*6024AL926SA60080V21***17.512.08.124,200210464901
CNPV*6024AL926SA60100V21***17.512.08.124,000210464912
CNPV*6024AL926SA66120V24***17.512.08.124,000210464923
CNPV*6024AL926TB60100V21***17.512.08.124,200210465147
CNPV*6024AL926TB66120V24***17.512.08.124,000210465026
CAP**6024AL82*TA60090V21***17.511.78.124,000210461056
CAP**6121AL926TB60100V21***17.511.78.124,200210461614
CAP**6121AL82*TA48070V17***17.511.78.124,400210461448
CAP**6124AL926SA60080V21***17.511.78.124,200210461724
CAP**6121AL926SA60080V21***17.511.78.124,200210461290
CAP**6024AL82*SA60090V21***17.511.78.124,000210461023
CAP**6121AL926SA60100V21***17.511.78.124,200210461301
CAP**6024AL82*TA66135V24***17.511.78.124,000210461067
CAP**6024AL82*SA66110V24***17.511.78.124,000210461045
CAP**6124AL82*SA60090V24***17.511.78.124,200210461813
CNPV*4821AL82*SA60090V21***17.511.78.124,200210464255
CNPV*4821AL82*TA48090V17***17.511.78.124,200210464266
CNPV*4821AL926SA60100V21***17.511.78.124,200210464133
CNPV*4821AL926SA60080V21***17.511.78.124,200210464122
CAP**6024AL82*SA60090V24***17.511.78.124,000210461034
CNPV*4824AL926TB66120V24***17.511.78.124,200210464703
CNPV*4821AL82*TA60090V21***17.511.78.124,200210464268
CAP**6024AL926SA66120V24***17.511.78.124,200210460967
CAP**6024AL926SA60100V21***17.511.78.124,000210460956
CNPV*4824AL926TB60080V21***17.511.78.124,400210464813
CNPV*4824AL926SA60080V21***17.511.78.124,200210464578
CNPV*6024AL926TB60080V21***17.511.78.124,400210465136
CNPV*4824AL926TB60100V21***17.511.78.124,400210464824
CNPV*4824AL82*TA66135V24***17.511.78.124,200210464700
CNPV*4824AL82*TA60090V21***17.511.78.124,200210464689
CNPV*4824AL82*SA60090V21***17.511.78.124,200210464656
CNPV*4824AL926SA60100V21***17.511.78.124,200210464589
CNPV*4824AL926SA66120V24***17.511.78.124,400210464600
CNPV*4821AL926TB60100V21***17.511.78.124,400210464468
Yearly running cost in 10 large cities$856-$3,254

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant 288BNV037*0**B*+TSTAT?
The Bryant 288BNV037*0**B*+TSTAT is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 71 certified matchups SEER2 ranges from 17.0-18.0.
Is the Bryant 288BNV037*0**B*+TSTAT good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Bryant 288BNV037*0**B*+TSTAT cost to run per year?
At its rated efficiency it costs about $856-$3,254 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,189 in Phoenix and $2,822 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant 288BNV037*0**B*+TSTAT?
ENERGY STAR lists 71 certified combinations for this outdoor unit. The highest-rated ones use CNPV*6024AL, CAP**6124AL, CAP**6121AL.
What refrigerant does the Bryant 288BNV037*0**B*+TSTAT use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,249/yrYou save $653/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant 288BNV037*0**B*+TSTAT
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,249
Current system, per year
$1,902
You save per year
$653
Payback
18.4 years
Net after 10 years
-$5,465

Cooling $630Heating $619Electricity used: 7,806 kWhSaved vs. a minimum-efficiency heat pump: $245

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 15, 2025. How we use the data.