ECO-AIR ECUO-48H

Average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #192 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,380 a year to run in a mixed climate like Atlanta.

SEER2
16.6 Cooling efficiency over a season
Average · beats 42%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
52,000 BTU/h87% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 52,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandECO-AIR
Outdoor unit modelECUO-48H
SeriesECU Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 10, 2025
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.6 (range 15.2-16.6)
EER2Efficiency at 95°F outdoors10.0-11.7
Cooling capacity45,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3-9.5
Capacity at 47°F47,000-56,000 BTU/h
Capacity at 17°F30,000-45,000 BTU/h
Capacity at 5°F41,000-52,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder87% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ECCC-60U at the standard test temperatures, in BTU/h:

Certified matchups6 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
ECCC-60U · cold climateS9V2B080U4VS**16.610.08.541,000217611263
ECMP-48U · cold climate-16.510.59.546,000216759899
ECMP-60U · cold climate-16.311.79.052,000216759900
ECCC-60U · cold climateMGV96U100C5C15.510.48.341,000217611291
ECCC-60U · cold climate-15.210.08.842,000216759919
ECCC-60U · cold climateMGV96U080C4C15.210.58.542,000217611290
Yearly running cost in 10 large cities$1,299-$3,247

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ECO-AIR ECUO-48H?
The ECO-AIR ECUO-48H is rated at up to 16.6 SEER2 and 10.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 15.2-16.6.
Is the ECO-AIR ECUO-48H good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 52,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the ECO-AIR ECUO-48H cost to run per year?
At its rated efficiency it costs about $1,299-$3,247 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,570 in Phoenix and $2,689 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ECO-AIR ECUO-48H?
ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use ECCC-60U, ECMP-48U, ECMP-60U.
What refrigerant does the ECO-AIR ECUO-48H use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,541/yrYou save $863/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ECO-AIR ECUO-48H
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,541
Current system, per year
$2,405
You save per year
$863
Payback
20.3 years
Net after 10 years
-$8,867

Cooling $975Heating $566Electricity used: 9,633 kWhSaved vs. a minimum-efficiency heat pump: $308

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.