4-ton central heat pump · TOP 24
TCL THH60TEI2NAH0H24
Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #184 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,682 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 8.0 Cooling efficiency on a 95°F dayBelow average · beats 0%
- Heat at 5°F
- 38,000 BTU/h72% of its 47°F outputBelow average · beats 5%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | TCL |
| Also sold as | ZERO |
| Outdoor unit model | THH60TEI2NAH0H24 |
| Series | TOP 24 |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 2, 2024 |
| Last certified | February 17, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 17.0) |
| EER2Efficiency at 95°F outdoors | 8.0 |
| Cooling capacity | 53,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.2 |
| Capacity at 47°F | 53,000 BTU/h |
| Capacity at 17°F | 38,000 BTU/h |
| Capacity at 5°F | 38,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with THH60IEI2NAH0H24 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| THH60IEI2NAH0H24 · cold climate | 17.0 | 8.0 | 8.2 | 38,000 | 216046768 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the TCL THH60TEI2NAH0H24: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- ZERO ZOV-60HDTB
Yearly running cost in 10 large cities
- Phoenix, AZ$1,826/yr
- Miami, FL$1,467/yr
- Houston, TX$1,638/yr
- Atlanta, GA$1,682/yr
- Los Angeles, CA$1,643/yr
- New York, NY$4,051/yr
- Chicago, IL$3,295/yr
- Denver, CO$2,744/yr
- Seattle, WA$1,690/yr
- Minneapolis, MN$3,398/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the TCL THH60TEI2NAH0H24?
- The TCL THH60TEI2NAH0H24 is rated at up to 17.0 SEER2 and 8.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the TCL THH60TEI2NAH0H24 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the TCL THH60TEI2NAH0H24 cost to run per year?
- At its rated efficiency it costs about $1,467-$4,051 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,826 in Phoenix and $3,398 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the TCL THH60TEI2NAH0H24 the same as the ZERO ZOV-60HDTB?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the TCL THH60TEI2NAH0H24?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses THH60IEI2NAH0H24.
- What refrigerant does the TCL THH60TEI2NAH0H24 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- York YD560E2D11 · cold climate17.0 SEER2 · 8.5 HSPF2
- Coleman HC19B482117.0 SEER2 · 8.1 HSPF2
- Luxaire HL19B482117.0 SEER2 · 8.1 HSPF2
- York YZT48B2117.0 SEER2 · 8.1 HSPF2
- Samsung AC048BXUPCH · cold climate17.0 SEER2 · 8.5 HSPF2
- UTL UCHA-60HDCSN2 · cold climate16.7 SEER2 · 9.0 HSPF2
- Luxaire XD560E2D11 · cold climate17.0 SEER2 · 8.5 HSPF2
- UTL UCHA-60HDCSN4 · cold climate16.7 SEER2 · 9.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of February 17, 2025. How we use the data.