3.5-ton central heat pump · F-SERIES
Friedrich FRP15AY42AJ2N
Below average cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.
Ranks #72 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,308 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 19,300 BTU/h47% of its 47°F outputAverage · beats 58%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,300 BTU/h at 5°F.
- You want a choice of indoor units - 129 certified pairings.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Friedrich |
| Outdoor unit model | FRP15AY42AJ2N |
| Series | F-SERIES |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 6, 2024 |
| Last certified | April 9, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 15.2-16.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 40,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.1 |
| Capacity at 47°F | 40,000 BTU/h |
| Capacity at 17°F | 27,000-40,000 BTU/h |
| Capacity at 5°F | 18,400-19,300 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY4824STANM at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 129 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| TCFY4824STANM · cold climate | FR801V1255A24UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655145 |
| TCFY4821STANM · cold climate | FR802V0754A17DZ | 16.0 | 11.7 | 8.1 | 19,300 | 215655185 |
| TCFY4821STANM · cold climate | FR801V1005A21UHU | 16.0 | 11.7 | 8.1 | 18,800 | 215655187 |
| TCFY4824STANM · cold climate | FR802V1255A24UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655188 |
| TCFY4824STANM · cold climate | FR801V1005A21UHU | 16.0 | 11.7 | 8.1 | 18,800 | 215655200 |
| TCFY4821STANM · cold climate | FR802V1005A21DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655210 |
| TCFY4824STANM · cold climate | FR801V1005A21DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655218 |
| TCFY4821STANM · cold climate | FR802V1004A17UH | 16.0 | 11.7 | 8.1 | 19,000 | 215655216 |
| TCFY4824STANM · cold climate | FR802V1255A24DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655239 |
| TCFY4821STANM · cold climate | FR802V0754A17UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655241 |
| TCFY4821STANM · cold climate | FR802V1005A21UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655254 |
| TCFY4821STANM · cold climate | FR802V0755A21DZ | 16.0 | 11.7 | 8.1 | 18,800 | 215655261 |
| TCFY4821STANM · cold climate | FR801V1005A21UHS | 16.0 | 11.7 | 8.1 | 18,800 | 215655264 |
| TCFY4821STANM · cold climate | FR801V0754A17DZ | 16.0 | 11.7 | 8.1 | 19,300 | 215655272 |
| TCFY4821STANM · cold climate | FR802V0755A21UH | 16.0 | 11.7 | 8.1 | 18,900 | 215655310 |
| TCFY4821STANM · cold climate | FR801V0704A17UH | 16.0 | 11.7 | 8.1 | 19,300 | 215655341 |
| TCFY4824STANM · cold climate | FR802V1005A21UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655343 |
| TCFY4824STANM · cold climate | FR802V1005A21DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655353 |
| TCFY4824STANM · cold climate | FR801V1005A21UHN | 16.0 | 11.7 | 8.1 | 18,800 | 215655362 |
| TCFY4821STANM · cold climate | FR801V0755A21UH | 16.0 | 11.7 | 8.1 | 18,900 | 215655361 |
| TCFY4821STANM · cold climate | FR801V1004A17UH | 16.0 | 11.7 | 8.1 | 19,000 | 215655367 |
| TCFY4821STANM · cold climate | FR801V1005A21UHN | 16.0 | 11.7 | 8.1 | 18,800 | 215655373 |
| TCFY4821STANM · cold climate | FR801V1005A21DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655372 |
| TCFY4821STANM · cold climate | FR801V0755A21DZ | 16.0 | 11.7 | 8.1 | 18,800 | 215655471 |
| TCFY4824STANM · cold climate | FR801V0755A21UH | 16.0 | 11.7 | 8.1 | 18,900 | 215655485 |
| TCFY4824STANM · cold climate | FR802V0755A21UH | 16.0 | 11.7 | 8.1 | 18,900 | 215655420 |
| TCFY4821STANM · cold climate | FR801V0754A17UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655426 |
| TCFY4824STANM · cold climate | FR801V1005A21UHS | 16.0 | 11.7 | 8.1 | 18,800 | 215655451 |
| TCFY4824STANM · cold climate | FR802V0755A21DZ | 16.0 | 11.7 | 8.1 | 18,800 | 215655455 |
| TCFY4824STANM · cold climate | FR801V1255A24DZ | 16.0 | 11.7 | 8.1 | 18,700 | 215655457 |
| TCFY4824STANM · cold climate | FR802V1505A24UH | 16.0 | 11.7 | 8.1 | 18,800 | 215655458 |
| TCFY4824STANM · cold climate | FR801V0755A21DZ | 16.0 | 11.7 | 8.1 | 18,800 | 215655460 |
| TCFY4821STANM · cold climate | FR951V0705A21UHU | 16.0 | 11.7 | 8.1 | 19,100 | 215654954 |
| TCFY4824STANM · cold climate | FR962V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215656374 |
| TCFY4821STANM · cold climate | FR962V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215656410 |
| TCFY4824STANM · cold climate | FR921V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215654973 |
| TCFY4821STANM · cold climate | FR921V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215654974 |
| TCFY4821STANM · cold climate | FR921V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655007 |
| TCFY4821STANM · cold climate | FR921V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655020 |
| TCFY4824STANM · cold climate | FR951V1155A24M4 | 16.0 | 11.7 | 8.1 | 18,800 | 215655021 |
| TCFY4821STANM · cold climate | FR962V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215656465 |
| TCFY4824STANM · cold climate | FR962V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215657479 |
| TCFY4821STANM · cold climate | FR951V1005A21UH | 16.0 | 11.7 | 8.1 | 19,000 | 215655091 |
| TCFY4824STANM · cold climate | FR951V0705A21UHU | 16.0 | 11.7 | 8.1 | 19,100 | 215655104 |
| TCFY4824STANM · cold climate | FR921V1155A24M4 | 16.0 | 11.7 | 8.1 | 18,800 | 215655114 |
| TCFY4824STANM · cold climate | FR921V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655122 |
| TCFY4824STANM · cold climate | FR951V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215655030 |
| TCFY4821STANM · cold climate | FR951V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215655042 |
| TCFY4821STANM · cold climate | FR951V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655046 |
| TCFY4824STANM · cold climate | FR951V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655049 |
| TCFY4821STANM · cold climate | FR951V1005A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655054 |
| TCFY4824STANM · cold climate | FR921V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655064 |
| TCFY4824STANM · cold climate | FR951V1005A21UH | 16.0 | 11.7 | 8.1 | 19,000 | 215655072 |
| TCFY4824STANM · cold climate | FR951V0705A21M4 | 16.0 | 11.7 | 8.1 | 19,100 | 215655073 |
| TCFY4824STANM · cold climate | FR962V1155A24M4 | 16.0 | 11.7 | 8.1 | 18,800 | 215656448 |
| TCFY4821STANM · cold climate | FR962V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215656455 |
| TCFY4824STANM · cold climate | FR962V0855A21M4 | 16.0 | 11.7 | 8.1 | 19,200 | 215656459 |
| FRH2VY4824STACN · cold climate | - | 16.0 | 12.0 | 8.1 | 18,400 | 216030728 |
| FRH2VY4821STACN · cold climate | - | 16.0 | 12.0 | 8.1 | 18,500 | 216030729 |
| TCFY4824STANM · cold climate | FR801V1505A24UH | 16.0 | 11.7 | 8.1 | 18,800 | 216543698 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,446/yr
- Miami, FL$1,175/yr
- Houston, TX$1,296/yr
- Atlanta, GA$1,308/yr
- Los Angeles, CA$1,273/yr
- New York, NY$3,124/yr
- Chicago, IL$2,535/yr
- Denver, CO$2,107/yr
- Seattle, WA$1,295/yr
- Minneapolis, MN$2,608/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Friedrich FRP15AY42AJ2N?
- The Friedrich FRP15AY42AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 129 certified matchups SEER2 ranges from 15.2-16.0.
- Is the Friedrich FRP15AY42AJ2N good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,300 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the Friedrich FRP15AY42AJ2N cost to run per year?
- At its rated efficiency it costs about $1,175-$3,124 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,446 in Phoenix and $2,608 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Friedrich FRP15AY42AJ2N?
- ENERGY STAR lists 129 certified combinations for this outdoor unit. The highest-rated ones use TCFY4824STANM, TCFY4821STANM, FRH2VY4824STACN.
- What refrigerant does the Friedrich FRP15AY42AJ2N use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- DuraSTAR DRHP15B42AJ2AN · cold climate16.0 SEER2 · 8.1 HSPF2
- Ameristar A5HP5048A116.0 SEER2 · 8.1 HSPF2
- Fujitsu FOP1542TJAYNA · cold climate16.0 SEER2 · 8.1 HSPF2
- American Standard N5HP5048A116.0 SEER2 · 8.1 HSPF2
- Guardian RHP15042B2116.0 SEER2 · 8.1 HSPF2
- American Standard N5HP5042A116.0 SEER2 · 8.1 HSPF2
- Luxaire THF2B42T2116.0 SEER2 · 8.1 HSPF2
- American Standard 5HPL5048A1 · cold climate16.0 SEER2 · 8.1 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 9, 2025. How we use the data.