HVAC Rated

3.5-ton central heat pump · F-SERIES

Friedrich FRP15AY42AJ2N

Below average cooling and heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #72 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,308 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
19,300 BTU/h47% of its 47°F output
Average · beats 58%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,300 BTU/h at 5°F.
  • You want a choice of indoor units - 129 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP15AY42AJ2N
SeriesF-SERIES
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 6, 2024
Last certifiedApril 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity40,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F40,000 BTU/h
Capacity at 17°F27,000-40,000 BTU/h
Capacity at 5°F18,400-19,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder47% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TCFY4824STANM at the standard test temperatures, in BTU/h:

Certified matchups129 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 129 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY4824STANM · cold climateFR801V1255A24UH16.011.78.118,800215655145
TCFY4821STANM · cold climateFR802V0754A17DZ16.011.78.119,300215655185
TCFY4821STANM · cold climateFR801V1005A21UHU16.011.78.118,800215655187
TCFY4824STANM · cold climateFR802V1255A24UH16.011.78.118,800215655188
TCFY4824STANM · cold climateFR801V1005A21UHU16.011.78.118,800215655200
TCFY4821STANM · cold climateFR802V1005A21DZ16.011.78.118,700215655210
TCFY4824STANM · cold climateFR801V1005A21DZ16.011.78.118,700215655218
TCFY4821STANM · cold climateFR802V1004A17UH16.011.78.119,000215655216
TCFY4824STANM · cold climateFR802V1255A24DZ16.011.78.118,700215655239
TCFY4821STANM · cold climateFR802V0754A17UH16.011.78.118,800215655241
TCFY4821STANM · cold climateFR802V1005A21UH16.011.78.118,800215655254
TCFY4821STANM · cold climateFR802V0755A21DZ16.011.78.118,800215655261
TCFY4821STANM · cold climateFR801V1005A21UHS16.011.78.118,800215655264
TCFY4821STANM · cold climateFR801V0754A17DZ16.011.78.119,300215655272
TCFY4821STANM · cold climateFR802V0755A21UH16.011.78.118,900215655310
TCFY4821STANM · cold climateFR801V0704A17UH16.011.78.119,300215655341
TCFY4824STANM · cold climateFR802V1005A21UH16.011.78.118,800215655343
TCFY4824STANM · cold climateFR802V1005A21DZ16.011.78.118,700215655353
TCFY4824STANM · cold climateFR801V1005A21UHN16.011.78.118,800215655362
TCFY4821STANM · cold climateFR801V0755A21UH16.011.78.118,900215655361
TCFY4821STANM · cold climateFR801V1004A17UH16.011.78.119,000215655367
TCFY4821STANM · cold climateFR801V1005A21UHN16.011.78.118,800215655373
TCFY4821STANM · cold climateFR801V1005A21DZ16.011.78.118,700215655372
TCFY4821STANM · cold climateFR801V0755A21DZ16.011.78.118,800215655471
TCFY4824STANM · cold climateFR801V0755A21UH16.011.78.118,900215655485
TCFY4824STANM · cold climateFR802V0755A21UH16.011.78.118,900215655420
TCFY4821STANM · cold climateFR801V0754A17UH16.011.78.118,800215655426
TCFY4824STANM · cold climateFR801V1005A21UHS16.011.78.118,800215655451
TCFY4824STANM · cold climateFR802V0755A21DZ16.011.78.118,800215655455
TCFY4824STANM · cold climateFR801V1255A24DZ16.011.78.118,700215655457
TCFY4824STANM · cold climateFR802V1505A24UH16.011.78.118,800215655458
TCFY4824STANM · cold climateFR801V0755A21DZ16.011.78.118,800215655460
TCFY4821STANM · cold climateFR951V0705A21UHU16.011.78.119,100215654954
TCFY4824STANM · cold climateFR962V1005A21M416.011.78.119,100215656374
TCFY4821STANM · cold climateFR962V1005A21M416.011.78.119,100215656410
TCFY4824STANM · cold climateFR921V0855A21M416.011.78.119,200215654973
TCFY4821STANM · cold climateFR921V0855A21M416.011.78.119,200215654974
TCFY4821STANM · cold climateFR921V0705A21M416.011.78.119,100215655007
TCFY4821STANM · cold climateFR921V1005A21M416.011.78.119,100215655020
TCFY4824STANM · cold climateFR951V1155A24M416.011.78.118,800215655021
TCFY4821STANM · cold climateFR962V0705A21M416.011.78.119,100215656465
TCFY4824STANM · cold climateFR962V0705A21M416.011.78.119,100215657479
TCFY4821STANM · cold climateFR951V1005A21UH16.011.78.119,000215655091
TCFY4824STANM · cold climateFR951V0705A21UHU16.011.78.119,100215655104
TCFY4824STANM · cold climateFR921V1155A24M416.011.78.118,800215655114
TCFY4824STANM · cold climateFR921V1005A21M416.011.78.119,100215655122
TCFY4824STANM · cold climateFR951V0855A21M416.011.78.119,200215655030
TCFY4821STANM · cold climateFR951V0855A21M416.011.78.119,200215655042
TCFY4821STANM · cold climateFR951V0705A21M416.011.78.119,100215655046
TCFY4824STANM · cold climateFR951V1005A21M416.011.78.119,100215655049
TCFY4821STANM · cold climateFR951V1005A21M416.011.78.119,100215655054
TCFY4824STANM · cold climateFR921V0705A21M416.011.78.119,100215655064
TCFY4824STANM · cold climateFR951V1005A21UH16.011.78.119,000215655072
TCFY4824STANM · cold climateFR951V0705A21M416.011.78.119,100215655073
TCFY4824STANM · cold climateFR962V1155A24M416.011.78.118,800215656448
TCFY4821STANM · cold climateFR962V0855A21M416.011.78.119,200215656455
TCFY4824STANM · cold climateFR962V0855A21M416.011.78.119,200215656459
FRH2VY4824STACN · cold climate-16.012.08.118,400216030728
FRH2VY4821STACN · cold climate-16.012.08.118,500216030729
TCFY4824STANM · cold climateFR801V1505A24UH16.011.78.118,800216543698
Yearly running cost in 10 large cities$1,175-$3,124

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP15AY42AJ2N?
The Friedrich FRP15AY42AJ2N is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 129 certified matchups SEER2 ranges from 15.2-16.0.
Is the Friedrich FRP15AY42AJ2N good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,300 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich FRP15AY42AJ2N cost to run per year?
At its rated efficiency it costs about $1,175-$3,124 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,446 in Phoenix and $2,608 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP15AY42AJ2N?
ENERGY STAR lists 129 certified combinations for this outdoor unit. The highest-rated ones use TCFY4824STANM, TCFY4821STANM, FRH2VY4824STACN.
What refrigerant does the Friedrich FRP15AY42AJ2N use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,433/yrYou save $629/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP15AY42AJ2N
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,433
Current system, per year
$2,063
You save per year
$629
Payback
23.8 years
Net after 10 years
-$8,706

Cooling $880Heating $553Electricity used: 8,957 kWhSaved vs. a minimum-efficiency heat pump: $149

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 9, 2025. How we use the data.