HVAC Rated

3-ton central heat pump · F-Series Plus

Friedrich FRP17AY36AJVC

Average cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #149 of 302 3 ton central heat pumps for cooling efficiency, and costs about $991 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
31,400 BTU/h91% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 31,400 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 242 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP17AY36AJVC
SeriesF-Series Plus
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 26, 2025
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.0-17.0)
EER2Efficiency at 95°F outdoors10.0-11.0
Cooling capacity34,000-34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5
Capacity at 47°F34,000-34,200 BTU/h
Capacity at 17°F32,000-32,600 BTU/h
Capacity at 5°F25,400-31,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder91% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RCFY3621STANM at the standard test temperatures, in BTU/h:

Certified matchups242 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 242 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
RCFY3621STANM · cold climateFR951V1005A21UHU17.011.09.531,000218327995
RCFY3621STANM · cold climateFR951V1005A21M4U17.011.09.531,000218327994
RCFY3621STANM · cold climateFR951V0855A21M4S17.011.09.531,000218327992
RCFY3621STANM · cold climateFR951V0705A21UHU17.011.09.531,000218327991
RCFY3621STANM · cold climateFR951V0705A21M4U17.011.09.531,000218327990
RCFY3621STANM · cold climateFR921V0855A21M4S17.011.09.531,000218327973
RCFY3621STANM · cold climateFR98MV1005A21UPS17.010.59.531,000218327965
RCFY3621STANM · cold climateFR98MV0855A21UPS17.011.09.531,000218327964
RCFY3621STANM · cold climateFR97MV1005A21DHS17.011.09.531,000218327959
RCFY3621STANM · cold climateFR97MV0855A21DHS17.011.09.531,000218327958
RCFY3617STANM · cold climateFR802V0754A17UHN17.011.09.530,800218327928
RCFY3621STANM · cold climateFR802V0754A17DZS17.010.59.531,000218327927
RCFY3617STANM · cold climateFR802V0754A17DZS17.010.59.531,000218327926
RCFY3621STANM · cold climateFR802V0754A17DZN17.010.59.531,000218327925
RCFY3617STANM · cold climateFR802V0754A17DZN17.010.59.531,000218327924
RCFY3621STANM · cold climateFR801V1005A21UHU17.011.09.530,800218327916
RCFY3621STANM · cold climateFR801V1005A21UHS17.011.09.530,800218327915
RCFY3621STANM · cold climateFR801V1005A21UHN17.011.09.530,800218327914
RCFY3621STANM · cold climateFR801V1005A21DZS17.011.09.530,800218327913
RCFY3621STANM · cold climateFR801V1005A21DZN17.011.09.530,800218327912
RCFY3621STANM · cold climateFR801V1004A17UHS17.011.09.531,000218327911
RCFY3617STANM · cold climateFR801V1004A17UHS17.011.09.531,000218327910
RCFY3621STANM · cold climateFR801V1004A17UHN17.011.09.531,000218327909
RCFY3617STANM · cold climateFR801V1004A17UHN17.011.09.531,000218327908
RCFY3621STANM · cold climateFR801V0755A21UHS17.011.09.530,800218327907
RCFY3621STANM · cold climateFR801V0755A21UHN17.011.09.530,800218327906
RCFY3621STANM · cold climateFR801V0755A21DZS17.011.09.530,800218327905
RCFY3621STANM · cold climateFR801V0755A21DZN17.011.09.530,800218327904
RCFY3621STANM · cold climateFR801V0754A17UHS17.011.09.531,000218327903
RCFY3617STANM · cold climateFR801V0754A17UHS17.011.09.530,800218327902
RCFY3621STANM · cold climateFR801V0754A17UHN17.011.09.531,000218327901
RCFY3617STANM · cold climateFR801V0754A17UHN17.011.09.530,800218327900
RCFY3621STANM · cold climateFR801V0754A17DZS17.010.59.531,000218327899
RCFY3617STANM · cold climateFR801V0754A17DZS17.010.59.531,000218327898
RCFY3621STANM · cold climateFR801V0754A17DZN17.010.59.531,000218327897
RCFY3617STANM · cold climateFR801V0754A17DZN17.010.59.531,000218327896
TCFY3621STANM · cold climateFR951V1005A21UHU17.011.09.531,000218328255
TCFY3621STANM · cold climateFR951V1005A21M4U17.011.09.531,000218328254
TCFY3621STANM · cold climateFR951V0855A21M4S17.011.09.531,000218328252
TCFY3621STANM · cold climateFR951V0705A21UHU17.011.09.531,000218328251
TCFY3621STANM · cold climateFR951V0705A21M4U17.011.09.531,000218328250
TCFY3621STANM · cold climateFR921V0855A21M4S17.011.09.531,000218328233
TCFY3621STANM · cold climateFR98MV1005A21UPS17.010.59.531,000218328225
TCFY3621STANM · cold climateFR98MV0855A21UPS17.011.09.531,000218328224
TCFY3621STANM · cold climateFR97MV1005A21DHS17.011.09.531,000218328219
TCFY3621STANM · cold climateFR97MV0855A21DHS17.011.09.531,000218328218
TCFY3621STANM · cold climateFR962V0855A21M4S17.011.09.531,000218328212
TCFY3621STANM · cold climateFR802V1005A21UHS17.011.09.530,800218328203
TCFY3621STANM · cold climateFR802V1005A21UHN17.011.09.530,800218328202
TCFY3621STANM · cold climateFR802V1005A21DZS17.011.09.530,800218328201
TCFY3621STANM · cold climateFR802V1005A21DZN17.011.09.530,800218328200
TCFY3621STANM · cold climateFR802V1004A17UHS17.011.09.531,000218328199
TCFY3617STANM · cold climateFR802V1004A17UHS17.011.09.531,000218328198
TCFY3621STANM · cold climateFR802V1004A17UHN17.011.09.531,000218328197
TCFY3617STANM · cold climateFR802V1004A17UHN17.011.09.531,000218328196
TCFY3621STANM · cold climateFR802V0755A21UHS17.011.09.530,800218328195
TCFY3621STANM · cold climateFR802V0755A21UHN17.011.09.530,800218328194
TCFY3621STANM · cold climateFR802V0755A21DZS17.011.09.530,800218328193
TCFY3621STANM · cold climateFR802V0755A21DZN17.011.09.530,800218328192
TCFY3621STANM · cold climateFR802V0754A17UHS17.011.09.531,000218328191
Yearly running cost in 10 large cities$942-$2,323

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP17AY36AJVC?
The Friedrich FRP17AY36AJVC is rated at up to 17.0 SEER2 and 11.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 242 certified matchups SEER2 ranges from 16.0-17.0.
Is the Friedrich FRP17AY36AJVC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 31,400 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich FRP17AY36AJVC cost to run per year?
At its rated efficiency it costs about $942-$2,323 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,134 in Phoenix and $1,920 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP17AY36AJVC?
ENERGY STAR lists 242 certified combinations for this outdoor unit. The highest-rated ones use RCFY3621STANM, RCFY3617STANM, TCFY3621STANM.
What refrigerant does the Friedrich FRP17AY36AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,111/yrYou save $652/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP17AY36AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,111
Current system, per year
$1,763
You save per year
$652
Payback
19.9 years
Net after 10 years
-$6,479

Cooling $708Heating $403Electricity used: 6,946 kWhSaved vs. a minimum-efficiency heat pump: $241

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.