HVAC Rated

2-ton central heat pump · K-SERIES

Friedrich FRP19AY24AJVC

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #11 of 331 2 ton central heat pumps for cooling efficiency, and costs about $591 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
19,500 BTU/h81% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandFriedrich
Outdoor unit modelFRP19AY24AJVC
SeriesK-SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 12, 2024
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 20.0-21.0)
EER2Efficiency at 95°F outdoors12.0-13.0
Cooling capacity22,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F22,800-24,000 BTU/h
Capacity at 17°F20,200-21,200 BTU/h
Capacity at 5°F17,400-19,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RCFY2421HEAAM at the standard test temperatures, in BTU/h:

Certified matchups59 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
RCFY2421HEAAM · cold climateFR801V0704A17UH21.013.010.018,500216551655
RCFY2421HEAAM · cold climateFR802V0754A17UH21.013.010.018,400216551667
RCFY2421HEAAM · cold climateFR97MV0855A21DH21.013.010.018,400216551709
RCFY2421HEAAM · cold climateFR98MV1005A21UP21.013.010.018,500216551711
RCFY2421HEAAM · cold climateFR98MV0855A21UP21.013.010.018,400216551713
RCFY2421HEAAM · cold climateFR97MV0603A17DH21.013.010.018,500216551740
RCFY2421HEAAM · cold climateFR962V0603A17M421.013.010.018,600216551725
RCFY2421HEAAM · cold climateFR97MV0703A17DH21.013.010.018,500216551727
RCFY2421HEAAM · cold climateFR98MV0603A17UP21.013.010.018,500216551733
RCFY2421HEAAM · cold climateFR962V0403A17M421.013.010.018,500216551735
RCFY2421HEAAM · cold climateFR951V0603A17M421.013.010.018,600216551633
RCFY2421HEAAM · cold climateFR921V0403A17M421.013.010.018,500216551627
RCFY2421HEAAM · cold climateFR951V0603A17UH21.013.010.018,600216551630
RCFY2421HEAAM · cold climateFR951V0403A17M421.013.010.018,500216551632
RCFY2421HEAAM · cold climateFR951V0403A17UH21.013.010.018,700216551639
RCFY2421HEAAM · cold climateFR921V0603A17M421.013.010.018,600216551637
RCFY2421HEAAM · cold climateFR801V0754A17UH21.013.010.018,400216551650
TCFY2421HEAAM · cold climateFR951V0403A17UH21.013.08.518,700216050983
TCFY2421HEAAM · cold climateFR951V0403A17M421.013.08.518,500216050986
TCFY2421HEAAM · cold climateFR951V0603A17UH21.013.08.518,600216050998
TCFY2421HEAAM · cold climateFR951V0603A17M421.013.08.518,600216050999
TCFY2421HEAAM · cold climateFR921V0603A17M421.013.08.518,600216051000
TCFY2421HEAAM · cold climateFR921V0403A17M421.013.08.518,500216051003
TCFY2421HEAAM · cold climateFR98MV1005A21UP21.013.08.518,500216051012
TCFY2421HEAAM · cold climateFR962V0603A17M421.013.08.518,600216051014
TCFY2421HEAAM · cold climateFR97MV0603A17DH21.013.08.518,500216051015
TCFY2421HEAAM · cold climateFR98MV0603A17UP21.013.08.518,500216051025
TCFY2421HEAAM · cold climateFR97MV0855A21DH21.013.08.518,400216051026
TCFY2421HEAAM · cold climateFR962V0403A17M421.013.08.518,500216051028
TCFY2421HEAAM · cold climateFR97MV0703A17DH21.013.08.518,500216051031
TCFY2421HEAAM · cold climateFR98MV0855A21UP21.013.08.518,400216051033
TCFY2421HEAAM · cold climateFR801V0754A17UH21.013.08.518,400216051041
TCFY2421HEAAM · cold climateFR802V0754A17UH21.013.08.518,400216051050
TCFY2421HEAAM · cold climateFR801V0704A17UH21.013.08.518,500216051054
TCFY2421HEAAMFR972V0603A17UPS21.013.08.517,500218728652
TCFY2421HEAAMFR972V0403A17UPS21.013.08.517,400218814083
RCFY2421HEAAM · cold climateFR801V0504A17UHU20.012.010.018,600216551661
RCFY2421HEAAM · cold climateFR802V0504A17UH20.012.010.018,500216551669
RCFY2421HEAAM · cold climateFR97MV1005A21DH20.012.010.018,400216551718
RCFY2421HEAAM · cold climateFR98MV0703A17UP20.012.010.018,500216551737
RCFY2421HEAAM · cold climateFR962V0703A17M420.012.010.018,600216551730
RCFY2421HEAAM · cold climateFR951V0703A17M420.012.010.018,600216551624
RCFY2421HEAAM · cold climateFR921V0703A17M420.012.010.018,600216551622
RCFY2421HEAAM · cold climateFR801V0504A17UHS20.012.010.018,500216551643
RCFY2421HEAAM · cold climateFR801V0504A17UHN20.012.010.018,500216551647
FRHMVY3621MEACA · cold climate-20.013.09.519,500215739593
TCFY2421HEAAM · cold climateFR951V0703A17M420.012.08.518,600216050985
TCFY2421HEAAM · cold climateFR921V0703A17M420.012.08.518,600216050997
TCFY2421HEAAM · cold climateFR97MV1005A21DH20.012.08.518,400216051013
TCFY2421HEAAM · cold climateFR962V0703A17M420.012.08.518,600216051019
TCFY2421HEAAM · cold climateFR98MV0703A17UP20.012.08.518,500216051034
TCFY2421HEAAM · cold climateFR801V0504A17UHN20.012.08.518,500216051044
TCFY2421HEAAM · cold climateFR802V0504A17UH20.012.08.518,500216051045
TCFY2421HEAAM · cold climateFR801V0504A17UHU20.012.08.518,600216051047
TCFY2421HEAAM · cold climateFR801V0504A17UHS20.012.08.518,500216051051
TCFY2421HEAAMFR802V1005A21UH20.013.08.518,400216706054
RCFY2421HEAAMFR802V1005A21UH20.013.08.518,400216706062
TCFY2421HEAAMFR972V0855A21UPS20.012.08.517,400218728654
TCFY2421HEAAMFR972V0705A21UPS20.012.08.517,400218728653
Yearly running cost in 10 large cities$511-$1,426

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Friedrich FRP19AY24AJVC?
The Friedrich FRP19AY24AJVC is rated at up to 21.0 SEER2 and 13.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 59 certified matchups SEER2 ranges from 20.0-21.0.
Is the Friedrich FRP19AY24AJVC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,500 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Friedrich FRP19AY24AJVC cost to run per year?
At its rated efficiency it costs about $511-$1,426 a year in electricity in large U.S. cities, depending on climate and local rates - for example $638 in Phoenix and $1,197 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Friedrich FRP19AY24AJVC?
ENERGY STAR lists 59 certified combinations for this outdoor unit. The highest-rated ones use RCFY2421HEAAM, TCFY2421HEAAM, FRHMVY3621MEACA.
What refrigerant does the Friedrich FRP19AY24AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $638/yrYou save $538/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Friedrich FRP19AY24AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$638
Current system, per year
$1,176
You save per year
$538
Payback
15.8 years
Net after 10 years
-$3,119

Cooling $382Heating $255Electricity used: 3,985 kWhSaved vs. a minimum-efficiency heat pump: $264

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.