5-ton central heat pump · NS22H Series
GE NS22H60MA4-**A
Very good cooling efficiency and average heating efficiency for a 5-ton central heat pump, but not rated for cold climates.
Ranks #17 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,619 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 8.7 Heating efficiency over a seasonAverage · beats 47%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 31,200 BTU/h54% of its 47°F outputAverage · beats 65%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 17 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS22H60MA4-**A |
| Series | NS22H Series |
| Type | Central heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 13, 2023 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 17.0-19.0) |
| EER2Efficiency at 95°F outdoors | 11.7-12.0 |
| Cooling capacity | 54,000-55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.7 |
| Capacity at 47°F | 55,000-56,000 BTU/h |
| Capacity at 17°F | 37,000-38,000 BTU/h |
| Capacity at 5°F | 29,800-31,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.84-2.12 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NAM60V2TA4 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NAM60V2TA4 | - | 19.0 | 12.0 | 8.7 | 29,800 | 212403760 |
| NCUC5060CT4+TDR | NF97U110V5C | 19.0 | 11.7 | 8.0 | 30,400 | 215283908 |
| NCUC50CT5D-**+TDR | NF97U110V5C | 19.0 | 11.7 | 8.0 | 30,400 | 215283912 |
| NCUC5060CT4+TDR | NF98U110M5C | 19.0 | 11.7 | 7.8 | 30,600 | 215438331 |
| NCUC60CT5D-**+TDR | NF97U110V5C | 18.0 | 11.7 | 8.2 | 31,200 | 215283920 |
| NCUU60CP4+TDR+TXV | NF97U110V5C | 18.0 | 11.7 | 8.2 | 31,200 | 215283929 |
| NCUC60CT4+TDR | NF97U110V5C | 18.0 | 11.7 | 8.2 | 31,200 | 215283916 |
| NCUC60CT4+TDR | NF98U110M5C | 18.0 | 11.7 | 8.2 | 31,200 | 215438334 |
| NCUU60CP4+TDR+TXV | NF98U110M5C | 18.0 | 11.7 | 8.2 | 31,200 | 215438338 |
| NCUC60DT4+TDR | NF97U135V5D | 18.0 | 11.7 | 8.1 | 30,800 | 215283922 |
| NCUC60DT5D-**+TDR | NF97U135V5D | 18.0 | 11.7 | 8.1 | 30,800 | 215283925 |
| NCUC60DT4+TDR | NF98U135M5D | 18.0 | 11.7 | 8.1 | 30,800 | 215438335 |
| NCUC50/60CT4 | NF97U110M5C | 18.0 | 11.7 | 8.0 | 30,600 | 212403777 |
| NCUC60CT4+TDR | NF97U110M5C | 17.0 | 11.7 | 8.5 | 31,200 | 212403785 |
| NCUU60CP4+TDR+TXV | NF97U110M5C | 17.0 | 11.7 | 8.5 | 31,200 | 212403795 |
| NCUC60DT4+TDR | NF97U135M5D | 17.0 | 11.7 | 8.2 | 30,800 | 212403788 |
| NCUC60DT4+TDR | NF96U135V5D | 17.0 | 11.7 | 8.2 | 30,800 | 212403787 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,714/yr
- Miami, FL$1,353/yr
- Houston, TX$1,538/yr
- Atlanta, GA$1,619/yr
- Los Angeles, CA$1,590/yr
- New York, NY$3,948/yr
- Chicago, IL$3,220/yr
- Denver, CO$2,689/yr
- Seattle, WA$1,662/yr
- Minneapolis, MN$3,334/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS22H60MA4-**A?
- The GE NS22H60MA4-**A is rated at up to 19.0 SEER2 and 12.0 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 17 certified matchups SEER2 ranges from 17.0-19.0.
- Is the GE NS22H60MA4-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
- How much does the GE NS22H60MA4-**A cost to run per year?
- At its rated efficiency it costs about $1,353-$3,948 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,714 in Phoenix and $3,334 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS22H60MA4-**A?
- ENERGY STAR lists 17 certified combinations for this outdoor unit. The highest-rated ones use NAM60V2TA4, NCUC5060CT4+TDR, NCUC50CT5D-**+TDR.
- What refrigerant does the GE NS22H60MA4-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Armstrong Air 4SHP22LX160P-**A19.0 SEER2 · 8.7 HSPF2
- Friedrich RD17AZ60AJ3N · cold climate19.0 SEER2 · 8.1 HSPF2
- Multi MFG MSD-60HD-B · cold climate19.0 SEER2 · 9.0 HSPF2
- Innovair TOV60H2XA · cold climate18.5 SEER2 · 9.2 HSPF2
- Keeprite C5H0V60*K*AAA · cold climate19.0 SEER2 · 9.0 HSPF2
- Airquest N5H9V60*K*AAA · cold climate17.5 SEER2 · 9.0 HSPF2
- Hisense AUWR-60U3TH5 · cold climate19.0 SEER2 · 9.0 HSPF2
- Bryant 249VAN060**AA · cold climate17.5 SEER2 · 9.0 HSPF2
See all 100 5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.