3-ton central heat pump · QUIETCOMFORT DELUXE 20 VS HP
Heil B5H0V36*K*AAA
Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #39 of 302 3 ton central heat pumps for cooling efficiency, and costs about $961 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.5 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 11.5 Cooling efficiency on a 95°F dayBelow average · beats 31%
- Heat at 5°F
- 26,000 BTU/h72% of its 47°F outputAverage · beats 48%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Heil |
| Also sold as | Arcoaire, Airquest, Keeprite, Day & Night, Comfortmaker, Tempstar, Kenmore, ACIQ |
| Outdoor unit model | B5H0V36*K*AAA |
| Series | QUIETCOMFORT DELUXE 20 VS HP |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | June 12, 2023 |
| Last certified | September 16, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.5 (range 16.0-19.5) |
| EER2Efficiency at 95°F outdoors | 9.0-11.5 |
| Cooling capacity | 32,600-35,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1-9.5 |
| Capacity at 47°F | 34,000-36,200 BTU/h |
| Capacity at 17°F | 29,400-31,800 BTU/h |
| Capacity at 5°F | 23,600-26,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.64-2.04 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 2,465 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218162465 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218162464 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218162463 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218164744 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218168538 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218171236 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218171235 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218171234 |
| FCMA5B60L0D*+WALLCON · cold climate | - | 19.5 | 11.5 | 9.5 | 24,400 | 218356238 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218161829 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218161828 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218161827 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218168326 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218164532 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218170598 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218170597 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218170596 |
| FCMA5B48L0C*+WALLCON · cold climate | - | 19.0 | 11.0 | 9.0 | 24,600 | 218356042 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172169 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172168 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172167 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172166 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172165 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172164 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172163 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172162 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218172161 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218165055 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218165054 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218165053 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163400 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163398 |
| EVD5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163396 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163395 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163394 |
| EVD5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163393 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163392 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163391 |
| EVD5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218163390 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171602 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171601 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171600 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171599 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171598 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171597 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218164866 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162831 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162830 |
| EVM5X61M24A*+WALLCON | *80CTL1352422B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162829 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162828 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162827 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162826 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171596 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171595 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218171594 |
| EVM5X61M24A*+WALLCON | *80CTL1102120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218164865 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218164864 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162825 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162824 |
| EVM5X61M24A*+WALLCON | *80CTL0902120B* | 19.0 | 11.0 | 8.5 | 23,600 | 218162823 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,034/yr
- Miami, FL$826/yr
- Houston, TX$928/yr
- Atlanta, GA$961/yr
- Los Angeles, CA$940/yr
- New York, NY$2,325/yr
- Chicago, IL$1,893/yr
- Denver, CO$1,578/yr
- Seattle, WA$973/yr
- Minneapolis, MN$1,955/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Heil B5H0V36*K*AAA?
- The Heil B5H0V36*K*AAA is rated at up to 19.5 SEER2 and 11.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2465 certified matchups SEER2 ranges from 16.0-19.5.
- Is the Heil B5H0V36*K*AAA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,000 BTU/h at 5°F with a COP of 2.04, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Heil B5H0V36*K*AAA cost to run per year?
- At its rated efficiency it costs about $826-$2,325 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,034 in Phoenix and $1,955 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Heil B5H0V36*K*AAA?
- ENERGY STAR lists 2465 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, FCMA5B48L0C*+WALLCON, EVD5X61M24A*+WALLCON.
- What refrigerant does the Heil B5H0V36*K*AAA use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Day & Night C5H0V36*K*AAA · cold climate19.5 SEER2 · 9.5 HSPF2
- Trane/American Standard 5HPL9036A1000A19.5 SEER2 · 9.2 HSPF2
- Carrier 27VNA036A*030 · cold climate19.5 SEER2 · 9.5 HSPF2
- GE Appliances NS18H36HA5 · cold climate19.3 SEER2 · 9.6 HSPF2
- Airquest H5H0V36*K*AAA · cold climate19.5 SEER2 · 9.5 HSPF2
- Lennox EL18KSLV-036-230A · cold climate19.3 SEER2 · 9.6 HSPF2
- Ruud UP18AZ36AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
- Bosch BOVB-36MTB-M19E · cold climate19.0 SEER2 · 10.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.