HVAC Rated

2-ton central heat pump · Mainline 18 SEER2 HP

Heil H5H8T24*K*AAA

Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #102 of 331 2 ton central heat pumps for cooling efficiency, and costs about $727 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
11,500 BTU/h45% of its 47°F output
Very good · beats 81%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • You want a choice of indoor units - 1,494 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandHeil
Also sold asArcoaire, Airquest, Comfortmaker, Day & Night, Keeprite
Outdoor unit modelH5H8T24*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 15.2-18.5)
EER2Efficiency at 95°F outdoors11.7-14.0
Cooling capacity22,200-25,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F24,000-25,400 BTU/h
Capacity at 17°F14,100-15,000 BTU/h
Capacity at 5°F10,700-11,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-2.24
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X32M17A at the standard test temperatures, in BTU/h:

Certified matchups1,494 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,494 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVM5X32M17A*80MSU0401712A*18.514.07.810,800216361519
EVM5X32M17A*80MSU0401712A*18.514.07.810,800216361520
EVM5X32M17A*80MSU0401712A*18.514.07.810,800216361521
EVM5X32M17A*80VSL0701412B*18.514.07.810,900216361495
EVM5X32M17A*80VSL0701412B*18.514.07.810,900216361496
EVM5X32M17A*80VSL0701412B*18.514.07.810,900216361497
EA*5X37M21A*96VSN0802120B*18.013.08.511,200216366632
EA*5X37M21A*96VSN0802120B*18.013.08.511,200216366633
EA*5X37M21A*96VSN0802120B*18.013.08.511,200216366634
EA*5X37M21A*+WALLCON*80CSU0401712B*18.013.08.511,200216366792
EA*5X37M21A*+WALLCON*80CSU0401712B*18.013.08.511,200216366794
EA*5X37M21A*+WALLCON*80CSU0401712B*18.013.08.511,200216366793
EA*5X37M21A*+WALLCON*80CSU0802120B*18.013.58.511,200216366809
EA*5X37M21A*+WALLCON*80CSU0802120B*18.013.58.511,200216366808
EA*5X37M21A*+WALLCON*80CSU0802120B*18.013.58.511,200216366810
EA*5X37M21A*97VTN1002122A*18.013.08.511,200216366888
EA*5X37M21A*97VTN1002122A*18.013.08.511,200216366889
EA*5X37M21A*97VTN1002122A*18.013.08.511,200216366890
EA*5X37M21A*97VTN0802120A*18.013.08.511,200216366873
EA*5X37M21A*97VTN0802120A*18.013.08.511,200216366872
EA*5X37M21A*97VTN0802120A*18.013.08.511,200216366874
EA*5X37M21A*80VSL1102122B*18.013.08.511,100216366432
EA*5X37M21A*80VSL1102122B*18.013.08.511,100216366433
EA*5X37M21A*80VSL1102122B*18.013.08.511,100216366434
EA*5X37M21A*80MSU0401712A*18.013.08.511,100216366440
EA*5X37M21A*80MSU0401712A*18.013.08.511,100216366441
EA*5X37M21A*80MSU0401712A*18.013.08.511,100216366442
EA*5X37M21A*80MSU0601716A*18.013.58.511,200216366448
EA*5X37M21A*80MSU0601716A*18.013.58.511,200216366449
EA*5X37M21A*80MSU0601716A*18.013.58.511,200216366450
EA*5X37M21A*80MSU0802120A*18.013.58.511,100216366456
EA*5X37M21A*80MSU0802120A*18.013.58.511,100216366457
EA*5X37M21A*80MSU0802120A*18.013.58.511,100216366458
EA*5X25M17A*+WALLCON*80CSU0401712B*18.013.08.511,200216365167
EA*5X25M17A*+WALLCON*80CSU0401712B*18.013.08.511,200216365168
EA*5X25M17A*+WALLCON*80CSU0401712B*18.013.08.511,200216365169
EA*5X37M21A*80VTL1102122B*18.013.08.511,200216366536
EA*5X37M21A*80VTL1102122B*18.013.08.511,200216366538
EA*5X37M21A*80VTL1102122B*18.013.08.511,200216366537
EA*5X37M21A*95MSU1002120A*18.013.08.511,200216366672
EA*5X37M21A*95MSU1002120A*18.013.08.511,200216366673
EA*5X37M21A*95MSU1002120A*18.013.08.511,200216366674
EA*5X37M21A*96VTN0802120B*18.013.08.511,200216366744
EA*5X37M21A*96VTN0802120B*18.013.08.511,200216366745
EA*5X37M21A*96VTN0802120B*18.013.08.511,200216366746
EA*5X37M21A*96VTN1002122B*18.013.08.511,200216366760
EA*5X37M21A*96VTN1002122B*18.013.08.511,200216366761
EA*5X37M21A*96VTN1002122B*18.013.08.511,200216366762
FTMA5B36L0C-18.013.08.110,700216368898
FTMA5B36L0C-18.013.08.110,700216368899
FTMA5B36L0C-18.013.08.110,700216368900
EA*5X37M21A*+WALLCON*97CMN0802120B*18.013.08.111,200216366592
EA*5X37M21A*+WALLCON*97CMN0802120B*18.013.08.111,200216366593
EA*5X37M21A*+WALLCON*97CMN0802120B*18.013.08.111,200216366594
EA*5X37M21A*+WALLCON*97CMN1002122B*18.013.08.111,200216366600
EA*5X37M21A*+WALLCON*97CMN1002122B*18.013.08.111,200216366601
EA*5X37M21A*+WALLCON*97CMN1002122B*18.013.08.111,200216366602
EA*5X37M21A*96VSN0601716B*18.013.08.111,200216366616
EA*5X37M21A*96VSN0601716B*18.013.08.111,200216366617
EA*5X37M21A*96VSN0601716B*18.013.08.111,200216366618
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil H5H8T24*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$588-$1,789

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil H5H8T24*K*AAA?
The Heil H5H8T24*K*AAA is rated at up to 18.5 SEER2 and 14.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1494 certified matchups SEER2 ranges from 15.2-18.5.
Is the Heil H5H8T24*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Heil H5H8T24*K*AAA cost to run per year?
At its rated efficiency it costs about $588-$1,789 a year in electricity in large U.S. cities, depending on climate and local rates - for example $755 in Phoenix and $1,518 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil H5H8T24*K*AAA the same as the Comfortmaker C5H8T24*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil H5H8T24*K*AAA?
ENERGY STAR lists 1494 certified combinations for this outdoor unit. The highest-rated ones use EVM5X32M17A, EA*5X37M21A, EA*5X37M21A*+WALLCON.
What refrigerant does the Heil H5H8T24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $764/yrYou save $451/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H8T24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$764
Current system, per year
$1,215
You save per year
$451
Payback
18.8 years
Net after 10 years
-$3,990

Cooling $438Heating $327Electricity used: 4,777 kWhSaved vs. a minimum-efficiency heat pump: $172

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.