HVAC Rated

2-ton central heat pump · Mainline 18 SEER2 HP

Tempstar T5H8T24*K*AAA

Very good cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #105 of 331 2 ton central heat pumps for cooling efficiency, and costs about $727 a year to run in a mixed climate like Atlanta.

SEER2
18.5 Cooling efficiency over a season
Very good · beats 77%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
11,500 BTU/h45% of its 47°F output
Very good · beats 81%

A good fit if…

  • You want low cooling bills - its SEER2 beats 77% of central heat pumps.
  • You want a choice of indoor units - 498 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandTempstar
Outdoor unit modelT5H8T24*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.5 (range 15.2-18.5)
EER2Efficiency at 95°F outdoors11.7-14.0
Cooling capacity22,200-25,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F24,000-25,400 BTU/h
Capacity at 17°F14,100-15,000 BTU/h
Capacity at 5°F10,700-11,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-2.24
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X32M17A at the standard test temperatures, in BTU/h:

Certified matchups498 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 498 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVM5X32M17A*80VSL0701412B*18.514.07.810,900216361502
EVM5X32M17A*80MSU0401712A*18.514.07.810,800216361526
EA*5X37M21A*96VSN0802120B*18.013.08.511,200216366639
EA*5X37M21A*+WALLCON*80CSU0401712B*18.013.08.511,200216366799
EA*5X37M21A*+WALLCON*80CSU0802120B*18.013.58.511,200216366815
EA*5X37M21A*97VTN0802120A*18.013.08.511,200216366879
EA*5X37M21A*97VTN1002122A*18.013.08.511,200216366895
EA*5X37M21A*80VSL1102122B*18.013.08.511,100216366439
EA*5X37M21A*80MSU0401712A*18.013.08.511,100216366447
EA*5X37M21A*80MSU0601716A*18.013.58.511,200216366455
EA*5X37M21A*80MSU0802120A*18.013.58.511,100216366463
EA*5X37M21A*80VTL1102122B*18.013.08.511,200216366543
EA*5X37M21A*95MSU1002120A*18.013.08.511,200216366679
EA*5X25M17A*+WALLCON*80CSU0401712B*18.013.08.511,200216365174
EA*5X37M21A*96VTN0802120B*18.013.08.511,200216366751
EA*5X37M21A*96VTN1002122B*18.013.08.511,200216366767
FTMA5B36L0C-18.013.08.110,700216368905
EA*5X37M21A*+WALLCON*97CMN0802120B*18.013.08.111,200216366599
EA*5X37M21A*+WALLCON*97CMN1002122B*18.013.08.111,200216366607
EA*5X37M21A*96VSN0601716B*18.013.08.111,200216366623
EA*5X37M21A*96VSN1002120B*18.013.08.111,100216366647
EA*5X37M21A*+WALLCON*80CSU0601716B*18.013.08.111,200216366807
EA*5X25M17A*80MSU0401712A*18.013.08.111,100216364942
EA*5X25M17A*80VSL0701412B*18.013.08.111,000216364918
EA*5X25M17A*80VSL0701716B*18.013.08.111,100216364926
EA*5X25M17A*+WALLCON*80CSU0401712A*18.013.08.111,200216364894
EA*5X37M21A*+WALLCON*97CTN1002122A*18.013.08.111,200216366855
EA*5X37M21A*+WALLCON*80CTL0901716B*18.013.08.111,200216366503
EA*5X37M21A*+WALLCON*80CTL0902120B*18.013.08.111,200216366511
EA*5X37M21A*+WALLCON*80CTL1102120B*18.013.08.111,200216366519
EA*5X37M21A*+WALLCON*80CSU0601716A*18.013.08.111,200216366399
EA*5X37M21A*80VSL0901716B*18.013.08.111,100216366423
EA*5X37M21A*80VTL0701716B*18.013.08.111,100216366527
EA*5X37M21A*+WALLCON*95CSU1002122B*18.013.08.111,200216366567
EA*5X37M21A*95MSU1002122A*18.013.08.111,100216366687
EA*5X37M21A*+WALLCON*96CTN1002122B*18.013.08.111,200216366719
EA*5X37M21A*96VTN0601716B*18.013.08.111,200216366735
EA*5X37M21A*96VTN1002120B*18.013.08.111,100216366759
EA*5X37M21A*+WALLCON*80CSU0401712A*18.013.08.111,200216366391
FCMA5B36L0C*+WALLCON-18.013.08.010,900216368921
EA*5X25M17A*+WALLCON*80CSU0601716B*18.013.08.011,200216365182
EVD5X37M21A*96VTN0802120B*18.013.57.810,900216364014
EVD5X36M21A*80VTL1102122B*18.013.57.810,800216363294
EVD5X31M17A*80VSL0451412B*18.013.57.811,000216362654
EVD5X31M17A*80VSL0701716B*18.013.57.811,100216362670
EVD5X31M17A*80VTL0451412B*18.013.57.811,000216362718
EVD5X36M21A*96VTN0802120B*18.013.57.810,800216363486
EVM5X31M17A*96VTN0601716B*18.013.57.811,100216361390
EVD5X37M21A*80VSL0701716B*18.013.57.810,900216363678
EVD5X37M21A*80MSU1002120A*18.013.57.810,900216363734
EVM5X31M17A*96VSN0601716B*18.013.57.811,100216361310
EVD5X38M17A*96VSN0601716B*18.013.57.811,100216364286
EVD5X38M17A*96VTN0601716B*18.013.57.811,100216364342
EVD5X38M17AOMV112K14A18.013.57.811,200216364366
QFVA5D3617X-18.014.07.811,300218695598
FTMA5X24L0B-17.513.08.111,100216152791
EA*5X25M17A*96VSN0601716B*17.513.08.111,200216365054
EA*5X25M17A*96VSN0801716B*17.513.08.111,100216365062
EA*5X25M17A*95MSU0601716A*17.513.08.111,100216365078
FCMA5X24L0B*+WALLCON-17.513.08.111,100216368913
Yearly running cost in 10 large cities$588-$1,789

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar T5H8T24*K*AAA?
The Tempstar T5H8T24*K*AAA is rated at up to 18.5 SEER2 and 14.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 498 certified matchups SEER2 ranges from 15.2-18.5.
Is the Tempstar T5H8T24*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Tempstar T5H8T24*K*AAA cost to run per year?
At its rated efficiency it costs about $588-$1,789 a year in electricity in large U.S. cities, depending on climate and local rates - for example $755 in Phoenix and $1,518 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar T5H8T24*K*AAA?
ENERGY STAR lists 498 certified combinations for this outdoor unit. The highest-rated ones use EVM5X32M17A, EA*5X37M21A, EA*5X37M21A*+WALLCON.
What refrigerant does the Tempstar T5H8T24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $764/yrYou save $451/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar T5H8T24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$764
Current system, per year
$1,215
You save per year
$451
Payback
18.8 years
Net after 10 years
-$3,990

Cooling $438Heating $327Electricity used: 4,777 kWhSaved vs. a minimum-efficiency heat pump: $172

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.