2-ton central heat pump · Deluxe 20 VS Heat Pump

Kenmore (C,H,T)5H0V24*K*AAA

Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #172 of 331 2 ton central heat pumps for cooling efficiency, and costs about $687 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
17,300 BTU/h70% of its 47°F output
Average · beats 47%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,300 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 103 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandKenmore
Outdoor unit model(C,H,T)5H0V24*K*AAA
SeriesDeluxe 20 VS Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.5-18.0)
EER2Efficiency at 95°F outdoors9.0-10.5
Cooling capacity22,400-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F23,200-24,600 BTU/h
Capacity at 17°F19,600-20,800 BTU/h
Capacity at 5°F16,300-17,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82-2.02
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA*5X37M21A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups103 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 103 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA*5X37M21A*+WALLCON · cold climate*80CSU0401712A*18.010.59.016,300215667818
EA*5X25M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,400215667192
EA*5X25M17A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667211
EA*5X37M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,500215667754
EA*5X37M21A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667842
EA*5X37M21A*+WALLCON · cold climate*80CTL0702120B*17.510.59.016,300215667850
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716A*17.510.59.016,300215667826
EA*5X37M21A*+WALLCON · cold climate*96CTN1002122B*17.510.59.016,300215667938
EA*5X37M21A*+WALLCON · cold climate*80CTL1102120B*17.510.59.016,300215667874
EA*5X37M21A*+WALLCON · cold climate*96CTN0601714B*17.510.59.016,400215667922
EA*5X37M21A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,300215667930
EA*5X25M17A*+WALLCON · cold climate*80CSU0401712A*17.510.59.016,400215667157
EA*5X25M17A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,400215667230
EA*5X25M17A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,400215667322
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716B*17.510.59.016,300215678401
EA*5X37M21A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,300215667858
EA*5X37M21A*+WALLCON · cold climate*80CTL0902120B*17.510.59.016,300215667866
EA*5X37M21A*+WALLCON · cold climate*97CMN0801714B*17.510.59.016,400215667906
EA*5X37M21A*+WALLCON · cold climate*97CMN1002122B*17.510.59.016,300215667914
EA*5X37M21A*+WALLCON · cold climate*97CTN1002122A*17.510.59.016,300215678431
EA*5X30M17A*+WALLCON · cold climate*80CTL0701412B*17.010.09.016,700215667426
EA*5X30M17A*+WALLCON · cold climate*80CTL0701716B*17.010.09.016,700215667444
EA*5X25M17A*+WALLCON · cold climate*80CSU0601716B*17.010.59.016,300215678241
EA*5X25M17A*+WALLCON · cold climate*97CTN0601716A*17.010.09.016,500215678251
EA*5X37M17A*+WALLCON · cold climate*96CTN0601714B*17.010.09.016,600215667802
EA*5X37M17A*+WALLCON · cold climate*80CSU0401712A*17.010.59.016,500215667730
EA*5X37M17A*+WALLCON · cold climate*80CSU0601716A*17.010.09.016,500215667738
EA*5X24M14A*+WALLCON · cold climate*80CTL0701412B*17.010.09.016,900215666940
EA*5X37M17A*+WALLCON · cold climate*80CTL0701716B*17.010.59.016,500215667762
EA*5X36M17A*+WALLCON · cold climate*80CSU0601716A*17.010.09.016,600215667591
EA*5X36M17A*+WALLCON · cold climate*80CTL0701716B*17.010.09.016,600215667642
EA*5X36M17A*+WALLCON · cold climate*80CTL0901716B*17.010.59.016,600215667659
EA*5X37M17A*+WALLCON · cold climate*80CSU0401712B*17.010.09.016,400215678351
EA*5X37M17A*+WALLCON · cold climate*80CSU0601716B*17.010.09.016,400215678361
EA*5X25M17A*+WALLCON · cold climate*97CMN0601714B*17.010.59.016,500215667248
EA*5X25M17A*+WALLCON · cold climate*97CMN0801714B*17.010.59.016,400215667266
EA*5X37M21A*+WALLCON · cold climate*97CMN0602120B*17.010.59.016,400215667898
EA*5X24M17A*+WALLCON · cold climate*80CTL0701412B*17.010.09.016,800215667031
EA*5X24M17A*+WALLCON · cold climate*80CTL0901716B*17.010.09.016,800215667066
EA*5X25M17A*+WALLCON · cold climate*80CSU0401712B*17.010.59.016,300215678231
EA*5X25M17A*+WALLCON · cold climate*80CTL0451712B*17.010.09.016,500215667175
EA*5X30M17A*+WALLCON · cold climate*80CTL0901716B*17.010.09.016,700215667462
EA*5X36M17A*+WALLCON · cold climate*96CTN0601714B*17.010.09.016,700215667714
EA*5X36M17A*+WALLCON · cold climate*96CTN0801714B*17.010.09.016,600215667722
EA*5X36M17A*+WALLCON · cold climate*97CMN0801714B*17.010.09.016,700215667692
EA*5X30M17A*+WALLCON · cold climate*96CTN0801714B*17.010.09.016,700215667553
EA*5X36M17A*+WALLCON · cold climate*80CSU0401712A*17.010.09.016,600215667572
EA*5X37M17A*+WALLCON · cold climate*80CTL0451712B*17.010.09.016,600215667746
EA*5X25M17A*+WALLCON · cold climate*97CTN0801716A*17.010.59.016,500215678261
EA*5X37M17A*+WALLCON · cold climate*96CTN0801714B*17.010.59.016,500215667810
EA*5X25M17A*+WALLCON · cold climate*96CTN0601714B*17.010.59.016,500215667302
EA*5X36M17A*+WALLCON · cold climate*97CMN0601714B*17.010.09.016,700215667675
EA*5X37M17A*+WALLCON · cold climate*97CTN0801716A*17.010.09.016,500215678381
EA*5X36M17A*+WALLCON · cold climate*97CTN0801716A*17.010.09.016,700215678341
EA*5X37M17A*+WALLCON · cold climate*97CMN0601714B*17.010.09.016,600215667778
EA*5X37M17A*+WALLCON · cold climate*97CMN0801714B*17.010.59.016,500215667786
EA*5X30M17A*+WALLCON · cold climate*80CSU0401712A*17.010.09.016,600215667374
EA*5X30M17A*+WALLCON · cold climate*80CSU0601716A*17.010.09.016,700215667391
EA*5X36M17A*+WALLCON · cold climate*80CTL0701412B*17.010.09.016,600215667625
EA*5X37M17A*+WALLCON · cold climate*80CTL0901716B*17.010.59.016,500215667770
Yearly running cost in 10 large cities$606-$1,649

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kenmore (C,H,T)5H0V24*K*AAA?
The Kenmore (C,H,T)5H0V24*K*AAA is rated at up to 18.0 SEER2 and 10.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 103 certified matchups SEER2 ranges from 15.5-18.0.
Is the Kenmore (C,H,T)5H0V24*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,300 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Kenmore (C,H,T)5H0V24*K*AAA cost to run per year?
At its rated efficiency it costs about $606-$1,649 a year in electricity in large U.S. cities, depending on climate and local rates - for example $751 in Phoenix and $1,381 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kenmore (C,H,T)5H0V24*K*AAA?
ENERGY STAR lists 103 certified combinations for this outdoor unit. The highest-rated ones use EA*5X37M21A*+WALLCON, EA*5X25M17A*+WALLCON, EA*5X37M17A*+WALLCON.
What refrigerant does the Kenmore (C,H,T)5H0V24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $747/yrYou save $455/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kenmore (C,H,T)5H0V24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$747
Current system, per year
$1,203
You save per year
$455
Payback
18.7 years
Net after 10 years
-$3,946

Cooling $454Heating $294Electricity used: 4,671 kWhSaved vs. a minimum-efficiency heat pump: $176

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.