HVAC Rated

2-ton central heat pump · QUIETCOMFORT DELUXE 20 VS HP

Heil H5H0V24*K*AAA

Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #170 of 331 2 ton central heat pumps for cooling efficiency, and costs about $687 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
17,300 BTU/h70% of its 47°F output
Average · beats 47%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,300 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 416 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, ACIQ
Outdoor unit modelH5H0V24*K*AAA
SeriesQUIETCOMFORT DELUXE 20 VS HP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.5-18.0)
EER2Efficiency at 95°F outdoors9.0-10.5
Cooling capacity22,400-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F23,200-24,600 BTU/h
Capacity at 17°F19,600-20,800 BTU/h
Capacity at 5°F16,300-17,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82-2.02
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA*5X37M21A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups416 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 416 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA*5X37M21A*+WALLCON · cold climate*80CSU0401712A*18.010.59.016,300215667812
EA*5X37M21A*+WALLCON · cold climate*80CSU0401712A*18.010.59.016,300215667813
EA*5X37M21A*+WALLCON · cold climate*80CSU0401712A*18.010.59.016,300215667814
EA*5X37M21A*+WALLCON · cold climate*80CSU0401712A*18.010.59.016,300216633071
EA*5X25M17A*+WALLCON · cold climate*80CSU0401712A*17.510.59.016,400215667145
EA*5X25M17A*+WALLCON · cold climate*80CSU0401712A*17.510.59.016,400215667147
EA*5X25M17A*+WALLCON · cold climate*80CSU0401712A*17.510.59.016,400215667149
EA*5X25M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,400215667181
EA*5X25M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,400215667183
EA*5X25M17A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667197
EA*5X25M17A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667200
EA*5X25M17A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667202
EA*5X37M21A*+WALLCON · cold climate*80CTL0702120B*17.510.59.016,300215667844
EA*5X37M21A*+WALLCON · cold climate*80CTL0702120B*17.510.59.016,300215667845
EA*5X37M21A*+WALLCON · cold climate*80CTL0702120B*17.510.59.016,300215667846
EA*5X37M21A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,300215667852
EA*5X37M21A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,300215667853
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716A*17.510.59.016,300215667820
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716A*17.510.59.016,300215667821
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716A*17.510.59.016,300215667822
EA*5X37M21A*+WALLCON · cold climate*96CTN1002122B*17.510.59.016,300215667932
EA*5X37M21A*+WALLCON · cold climate*96CTN1002122B*17.510.59.016,300215667933
EA*5X37M21A*+WALLCON · cold climate*96CTN1002122B*17.510.59.016,300215667934
EA*5X37M21A*+WALLCON · cold climate*97CMN0801714B*17.510.59.016,400215667900
EA*5X37M21A*+WALLCON · cold climate*97CMN0801714B*17.510.59.016,400215667901
EA*5X37M21A*+WALLCON · cold climate*97CMN0801714B*17.510.59.016,400215667902
EA*5X37M21A*+WALLCON · cold climate*80CTL1102120B*17.510.59.016,300215667868
EA*5X37M21A*+WALLCON · cold climate*80CTL1102120B*17.510.59.016,300215667869
EA*5X37M21A*+WALLCON · cold climate*80CTL1102120B*17.510.59.016,300215667870
EA*5X37M21A*+WALLCON · cold climate*96CTN0601714B*17.510.59.016,400215667918
EA*5X37M21A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,300215667924
EA*5X37M21A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,300215667925
EA*5X37M21A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,300215667926
EA*5X25M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,400215667179
EA*5X37M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,500215667748
EA*5X37M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,500215667749
EA*5X37M17A*+WALLCON · cold climate*80CTL0701412B*17.510.59.016,500215667750
EA*5X25M17A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,400215667216
EA*5X25M17A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,400215667219
EA*5X25M17A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,400215667221
EA*5X25M17A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,400215667308
EA*5X25M17A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,400215667311
EA*5X25M17A*+WALLCON · cold climate*96CTN0801714B*17.510.59.016,400215667313
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716B*17.510.59.016,300215678395
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716B*17.510.59.016,300215678396
EA*5X37M21A*+WALLCON · cold climate*80CSU0601716B*17.510.59.016,300215678397
EA*5X37M21A*+WALLCON · cold climate*80CTL0901716B*17.510.59.016,300215667854
EA*5X37M21A*+WALLCON · cold climate*80CTL0902120B*17.510.59.016,300215667860
EA*5X37M21A*+WALLCON · cold climate*80CTL0902120B*17.510.59.016,300215667861
EA*5X37M21A*+WALLCON · cold climate*80CTL0902120B*17.510.59.016,300215667862
EA*5X37M21A*+WALLCON · cold climate*97CTN1002122A*17.510.59.016,300215678425
EA*5X37M21A*+WALLCON · cold climate*97CTN1002122A*17.510.59.016,300215678426
EA*5X37M21A*+WALLCON · cold climate*97CTN1002122A*17.510.59.016,300215678427
EA*5X37M21A*+WALLCON · cold climate*97CMN1002122B*17.510.59.016,300215667908
EA*5X37M21A*+WALLCON · cold climate*97CMN1002122B*17.510.59.016,300215667909
EA*5X37M21A*+WALLCON · cold climate*97CMN1002122B*17.510.59.016,300215667910
EA*5X37M21A*+WALLCON · cold climate*96CTN0601714B*17.510.59.016,400215667916
EA*5X37M21A*+WALLCON · cold climate*96CTN0601714B*17.510.59.016,400215667917
EA*5X37M21A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667836
EA*5X37M21A*+WALLCON · cold climate*80CTL0701716B*17.510.59.016,400215667838
Yearly running cost in 10 large cities$606-$1,649

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Heil H5H0V24*K*AAA?
The Heil H5H0V24*K*AAA is rated at up to 18.0 SEER2 and 10.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 416 certified matchups SEER2 ranges from 15.5-18.0.
Is the Heil H5H0V24*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,300 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Heil H5H0V24*K*AAA cost to run per year?
At its rated efficiency it costs about $606-$1,649 a year in electricity in large U.S. cities, depending on climate and local rates - for example $751 in Phoenix and $1,381 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Heil H5H0V24*K*AAA?
ENERGY STAR lists 416 certified combinations for this outdoor unit. The highest-rated ones use EA*5X37M21A*+WALLCON, EA*5X25M17A*+WALLCON, EA*5X37M17A*+WALLCON.
What refrigerant does the Heil H5H0V24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $747/yrYou save $455/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H0V24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$747
Current system, per year
$1,203
You save per year
$455
Payback
18.7 years
Net after 10 years
-$3,946

Cooling $454Heating $294Electricity used: 4,671 kWhSaved vs. a minimum-efficiency heat pump: $176

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.