HVAC Rated

2-ton central heat pump · XD16H-LGWP

Midea MOVC-24HDN10-M16G

Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #174 of 331 2 ton central heat pumps for cooling efficiency, and costs about $703 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
17,200 BTU/h72% of its 47°F output
Below average · beats 9%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,200 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 32 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandMidea
Outdoor unit modelMOVC-24HDN10-M16G
SeriesXD16H-LGWP
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 8, 2025
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors10.5-11.7
Cooling capacity18,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F18,000-24,000 BTU/h
Capacity at 17°F14,800-20,200 BTU/h
Capacity at 5°F12,800-17,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-1.84
ENERGY STAR cold climateYes
Heating output as it gets colder72% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVME24B2MN10TD at the standard test temperatures, in BTU/h:

Certified matchups32 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
MVME24B2MN10TD · cold climate-18.011.78.517,200217752320
MVME24B2MN10TB · cold climate-18.011.78.517,200217753644
MHVE18A1MN10TB · cold climate-16.011.79.012,800217752334
MPUE18A1MN10TA · cold climate-16.011.79.012,900217752336
MPCE18A1MN10TA · cold climate-16.011.79.012,900217752340
MC**2430AN10TH · cold climateMGV97U060B3A16.010.68.516,800217752328
MC**2430AN10TH · cold climateMGV97U080B3A16.010.68.516,800217752329
MC**2430BN10TH · cold climateMGV97U060B3A16.010.68.516,800217752330
MC**2430BN10TH · cold climateMGV97U080B3A16.010.68.516,800217752331
MPUE24A1MN10TA · cold climate-16.011.78.516,700217752337
MPCE24A1MN10TA · cold climate-16.011.78.516,700217752341
MC**3036BN10TH · cold climateMGV97U060B3A16.010.68.516,800217752343
MC**3036BN10TH · cold climateMGV97U080B3A16.010.68.516,800217752344
MC**2430AN10TH+MEME05A3B · cold climate-16.010.68.516,800217752495
MC**2430BN10TH+MEME05B4B · cold climate-16.010.68.516,800217752496
MC**3036BN10TH+MEME05B4B · cold climate-16.010.68.516,800217752497
MC**2430AN10TH · cold climateMGV96U060B3C16.010.68.516,800217752870
MC**2430AN10TH · cold climateMGV96U080B3C16.010.68.516,800217752871
MC**2430BN10TH · cold climateMGV96U060B3C16.010.68.516,800217752872
MC**2430BN10TH · cold climateMGV96U080B3C16.010.68.516,800217752873
MC**3036BN10TH · cold climateMGV96U060B3C16.010.68.516,800217752879
MC**3036BN10TH · cold climateMGV96U080B3C16.010.68.516,800217752880
MC**2430BN10TH · cold climateY82E080B12LMPS116.010.68.516,800218743967
MC**3036BN10TH · cold climateY82E080B12LMPS116.010.68.516,800218743966
MC**3036BN10TH · cold climateY82E060A12LMPS116.010.68.516,800218743965
MC**2430AN10TH · cold climateY82E060A12LMPS116.010.68.516,800218743964
MC**2430BN10TH · cold climateBGK80A080B3A16.010.68.516,800218743962
MC**3036BN10TH · cold climateBGK80A080B3A16.010.68.516,800218743961
MC**3036BN10TH · cold climateBGK80A060A3A16.010.68.516,800218743960
MC**2430AN10TH · cold climateBGK80A060A3A16.010.68.516,800218743959
MHVE24A1MN10TB · cold climate-15.210.59.016,800217752335
MVMP24B2MN10TA · cold climate-15.210.68.517,000217752327
Yearly running cost in 10 large cities$627-$1,683

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea MOVC-24HDN10-M16G?
The Midea MOVC-24HDN10-M16G is rated at up to 18.0 SEER2 and 11.7 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 32 certified matchups SEER2 ranges from 15.2-18.0.
Is the Midea MOVC-24HDN10-M16G good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,200 BTU/h at 5°F with a COP of 1.84, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Midea MOVC-24HDN10-M16G cost to run per year?
At its rated efficiency it costs about $627-$1,683 a year in electricity in large U.S. cities, depending on climate and local rates - for example $774 in Phoenix and $1,407 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea MOVC-24HDN10-M16G?
ENERGY STAR lists 32 certified combinations for this outdoor unit. The highest-rated ones use MVME24B2MN10TD, MVME24B2MN10TB, MHVE18A1MN10TB.
What refrigerant does the Midea MOVC-24HDN10-M16G use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $768/yrYou save $470/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea MOVC-24HDN10-M16G
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$768
Current system, per year
$1,238
You save per year
$470
Payback
19.2 years
Net after 10 years
-$4,305

Cooling $469Heating $299Electricity used: 4,800 kWhSaved vs. a minimum-efficiency heat pump: $181

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.