2-ton central heat pump · MVB Series
MDV MOX430-24HFN10-M3
Very good cooling efficiency and excellent heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #111 of 331 2 ton central heat pumps for cooling efficiency, and costs about $654 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.4 Cooling efficiency over a seasonVery good · beats 75%
- HSPF2
- 10.4 Heating efficiency over a seasonExcellent · beats 94%
- EER2
- 10.8 Cooling efficiency on a 95°F dayBelow average · beats 19%
- Heat at 5°F
- 21,600 BTU/h84% of its 47°F outputAverage · beats 67%
A good fit if…
- You want low cooling bills - its SEER2 beats 75% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 94% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | MOX430-24HFN10-M3 |
| Series | MVB Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.4 (range 15.2-18.4) |
| EER2Efficiency at 95°F outdoors | 9.7-11.7 |
| Cooling capacity | 24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-10.4 |
| Capacity at 47°F | 24,000-26,000 BTU/h |
| Capacity at 17°F | 18,000-20,800 BTU/h |
| Capacity at 5°F | 19,000-21,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-2.14 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVBM-24B18T3N10 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 69 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| MVBM-24B18T3N10 · cold climate | RG19080B12MPS1 | 18.4 | 10.8 | 9.9 | 21,000 | 217753577 |
| MVBC-24HWFN10-MB3E · cold climate | - | 18.2 | 11.0 | 9.7 | 21,600 | 214861552 |
| MVBC-24HWFN10-MB3E-D · cold climate | - | 18.1 | 11.0 | 9.7 | 21,600 | 214861598 |
| MVBC-24HWFN10-MB3E-MAS · cold climate | - | 18.1 | 11.0 | 9.7 | 21,600 | 216030937 |
| MVBC-24HWFPN10-MB3E · cold climate | - | 18.1 | 11.0 | 9.7 | 21,600 | 215865883 |
| MVBM-24B18T3N10 · cold climate | MGV96U060B3C | 17.8 | 10.8 | 9.2 | 20,000 | 217607691 |
| MVBM-24A18T3N10 · cold climate | RL18060A12MPS1 | 17.7 | 10.5 | 9.4 | 21,000 | 217753626 |
| MVBM-24B18T3N10 · cold climate | MGV96U080B3C | 17.6 | 10.7 | 9.1 | 20,000 | 217607692 |
| MVBM-24A18T3N10 · cold climate | GR9T960403AN | 17.6 | 10.3 | 9.1 | 21,000 | 217754249 |
| MVBDM-24HWFN10-WA3-D · cold climate | - | 17.5 | 11.7 | 9.0 | 19,000 | 217678014 |
| MVBM-24A18T3N10 · cold climate | RG19040A10MPS1 | 17.5 | 10.1 | 8.8 | 20,000 | 217753575 |
| MVBE-24HWFN10-WM3E · cold climate | - | 17.4 | 10.8 | 10.4 | 19,600 | 215894240 |
| MVBE-24HWFN10-WM3E-MAS · cold climate | - | 17.4 | 10.8 | 10.4 | 19,600 | 216030945 |
| MVBM-24A18T3N10 · cold climate | GR9T960303AN | 17.4 | 10.2 | 9.2 | 21,000 | 217754248 |
| MVBM-24B18T3N10 · cold climate | S9V2B040U3VS*** | 17.2 | 10.5 | 8.5 | 20,000 | 217550337 |
| MVBM-24B18T3N10 · cold climate | S9V2B060U4VS*** | 17.2 | 10.5 | 8.5 | 20,000 | 217550338 |
| MVBM-24B18T3N10 · cold climate | S9V2B060D3VS*** | 17.2 | 10.5 | 8.5 | 20,000 | 217550339 |
| MVBM-24B18T3N10 · cold climate | RL18080B12MPS1 | 17.1 | 10.9 | 9.3 | 20,000 | 217753627 |
| MVBM-24B18T3N10 · cold climate | S9V2B080D4VS*** | 17.1 | 10.5 | 9.1 | 20,000 | 217753446 |
| MVBM-24A18T3N10 · cold climate | GR9S920403AN | 17.1 | 10.3 | 9.1 | 20,000 | 217754242 |
| MVBM-24B18T3N10 · cold climate | S9V2B040D3VS*** | 17.1 | 10.4 | 9.0 | 20,000 | 217753445 |
| MVBM-24B18T3N10 · cold climate | GD9S960603BN | 17.0 | 10.3 | 9.3 | 20,000 | 217754254 |
| MVBM-24B18T3N10 · cold climate | ML193DF070XE36B* | 17.0 | 10.4 | 9.1 | 20,000 | 217754232 |
| MVBM-24A18T3N10 · cold climate | RL18040A12MPS1 | 16.9 | 10.6 | 9.2 | 20,000 | 217753625 |
| MVBM-24B18T3N10 · cold climate | ML193DF045XE36B* | 16.9 | 10.4 | 9.0 | 20,000 | 217754231 |
| MVBM-24B18T3N10 · cold climate | MGV80M080B4NB | 16.8 | 10.4 | 9.2 | 20,000 | 218731280 |
| MVBM-24B18T3N10 · cold climate | S9X1B040D3PSB** | 16.8 | 10.3 | 9.0 | 20,000 | 217753447 |
| MVBM-24B18T3N10 · cold climate | S9X2B040D3PSB** | 16.8 | 10.3 | 9.0 | 20,000 | 217753515 |
| MVBM-24B18T3N10 · cold climate | RG19060B12MPS1 | 16.7 | 10.6 | 9.6 | 21,000 | 217753529 |
| MVBM-24A18T3N10 · cold climate | RG19060A10MPS1 | 16.7 | 10.1 | 9.3 | 21,000 | 217753576 |
| MVBM-24B18T3N10 · cold climate | MGV80M080B4A | 16.7 | 10.4 | 9.2 | 20,000 | 217753324 |
| MVBM-24B18T3N10 · cold climate | ML296UH070XV36B* | 16.7 | 10.2 | 9.2 | 20,000 | 217754241 |
| MVBM-24A18T3N10 · cold climate | C45-2-V | 16.6 | 10.0 | 9.1 | 20,000 | 217615676 |
| MVBM-24B18T3N10 · cold climate | ML296UH045XV36B* | 16.6 | 10.1 | 9.0 | 20,000 | 217754240 |
| MVBM-24B18T3N10 · cold climate | ML193UH030XE36B* | 16.6 | 10.3 | 8.9 | 20,000 | 217754233 |
| MVBM-24B18T3N10 · cold climate | ML193UH070XE36B* | 16.6 | 10.3 | 8.9 | 20,000 | 217754235 |
| MVBM-24A18T3N10 · cold climate | GR9T960603AN | 16.5 | 10.3 | 9.2 | 21,000 | 217754250 |
| MVBM-24B18T3N10 · cold climate | MGV80M060B4A | 16.5 | 10.3 | 9.1 | 20,000 | 217753323 |
| MVBM-24B18T3N10 · cold climate | MGV80M060B4NB | 16.5 | 10.2 | 9.0 | 20,000 | 218731279 |
| MVBM-24B18T3N10 · cold climate | C60-2-V | 16.4 | 10.4 | 9.3 | 20,000 | 217615677 |
| MVBM-24B18T3N10 · cold climate | S9X1B040U3PSB** | 16.4 | 10.4 | 9.1 | 20,000 | 217753448 |
| MVBM-24B18T3N10 · cold climate | S9X2B040U3PSB** | 16.4 | 10.4 | 9.1 | 20,000 | 217753516 |
| MVBM-24A18T3N10 · cold climate | MGV80M060A3NB | 16.4 | 10.3 | 9.1 | 20,000 | 218731278 |
| MVBM-24A18T3N10 · cold climate | MGV80M060A3A | 16.3 | 10.2 | 9.1 | 20,000 | 217753322 |
| MVBM-24B18T3N10 · cold climate | ML296DF045XV36B* | 16.3 | 10.0 | 9.1 | 20,000 | 217754239 |
| MVBM-24B18T3N10 · cold climate | GR9S920603BN | 16.2 | 10.4 | 9.3 | 20,000 | 217754243 |
| MVBM-24B18T3N10 · cold climate | ML196UH045XE36B* | 16.2 | 10.3 | 9.1 | 20,000 | 217754237 |
| MVBM-24A18T3N10 · cold climate | GR9S960403AN | 16.2 | 10.2 | 9.1 | 21,000 | 217754245 |
| MVBM-24B18T3N10 · cold climate | GD9T960603BN | 16.1 | 10.3 | 9.3 | 20,000 | 217754256 |
| MVBM-24A18T3N10 · cold climate | MGV80M040A3NB | 16.1 | 10.1 | 8.9 | 20,000 | 218731277 |
| MVBM-24B18T3N10 · cold climate | GR9T960803BN | 16.0 | 10.3 | 9.2 | 20,000 | 217754252 |
| MVBL-24HWFN10-MI3 · cold climate | - | 16.0 | 10.0 | 9.0 | 19,000 | 216620293 |
| MVBM-24B18T3N10 · cold climate | - | 16.0 | 10.0 | 9.0 | 19,000 | 216620305 |
| MVBM-24A18T3N10 · cold climate | - | 16.0 | 10.0 | 9.0 | 19,000 | 216620304 |
| MVBM-24B18T3N10-MAS · cold climate | - | 16.0 | 10.0 | 9.0 | 19,000 | 217509968 |
| MVBM-24B18T3N10 · cold climate | ML196UH070XE36B* | 16.0 | 10.4 | 9.0 | 20,000 | 217754238 |
| MVBM-24A18T3N10-MAS · cold climate | - | 16.0 | 10.0 | 9.0 | 19,000 | 218735539 |
| MVBM-24A18T3N10 · cold climate | MGV80M040A3A | 16.0 | 10.0 | 8.9 | 20,000 | 217753321 |
| MVBM-24B18T3N10 · cold climate | GR9S920803BN | 15.9 | 10.3 | 9.3 | 20,000 | 217754244 |
| MVBM-24B18T3N10 · cold climate | GR9S960803BN | 15.9 | 10.3 | 9.3 | 20,000 | 217754247 |
Yearly running cost in 10 large cities
- Phoenix, AZ$741/yr
- Miami, FL$611/yr
- Houston, TX$664/yr
- Atlanta, GA$654/yr
- Los Angeles, CA$632/yr
- New York, NY$1,542/yr
- Chicago, IL$1,247/yr
- Denver, CO$1,034/yr
- Seattle, WA$633/yr
- Minneapolis, MN$1,278/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOX430-24HFN10-M3?
- The MDV MOX430-24HFN10-M3 is rated at up to 18.4 SEER2 and 10.8 EER2 for cooling and up to 10.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 69 certified matchups SEER2 ranges from 15.2-18.4.
- Is the MDV MOX430-24HFN10-M3 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 2.14, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOX430-24HFN10-M3 cost to run per year?
- At its rated efficiency it costs about $611-$1,542 a year in electricity in large U.S. cities, depending on climate and local rates - for example $741 in Phoenix and $1,278 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOX430-24HFN10-M3?
- ENERGY STAR lists 69 certified combinations for this outdoor unit. The highest-rated ones use MVBM-24B18T3N10, MVBC-24HWFN10-MB3E, MVBC-24HWFN10-MB3E-D.
- What refrigerant does the MDV MOX430-24HFN10-M3 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- DuraSTAR DRU1U24S2A · cold climate18.4 SEER2 · 10.4 HSPF2
- Midea MO1BE-H24B-2A · cold climate18.4 SEER2 · 10.4 HSPF2
- DuraSTAR DRU1H24S2A · cold climate18.4 SEER2 · 10.5 HSPF2
- ECOTEMP W5H8T24*K*AAA18.5 SEER2 · 8.1 HSPF2
- InfinityLiving EZ-24-HPB · cold climate18.4 SEER2 · 10.0 HSPF2
- Kinghome KD24UXO18.5 SEER2 · 8.3 HSPF2
- MRCOOL CENTRAL-24-HP-C-230B00-O · cold climate18.4 SEER2 · 10.0 HSPF2
- WeatherMaker PH8TAN524**AB18.5 SEER2 · 8.5 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.