Below average cooling and heating efficiency for a 1.5-ton central heat pump, and certified for cold climates.

Ranks #113 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $707 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
19,000 BTU/h78% of its 47°F output
Below average · beats 5%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,000 BTU/h at 5°F.
  • You want a choice of indoor units - 40 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandRunTru
Also sold asAmeristar
Outdoor unit modelA5HL5024A1
SeriesA5HL5
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 25, 2025
Last certifiedJune 23, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7
Cooling capacity21,000-23,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1
Capacity at 47°F21,200-23,000 BTU/h
Capacity at 17°F19,000-21,000 BTU/h
Capacity at 5°F18,000-19,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.80
ENERGY STAR cold climateYes
Heating output as it gets colder78% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with A5AHV002A1B3 at the standard test temperatures, in BTU/h:

Certified matchups40 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
A5AHV002A1B3 · cold climate-16.011.78.118,000216776156
A5AHV002A1B3 · cold climate-16.011.78.118,000216776160
5TXCB003AS3 · cold climateA951X060BU4SA15.211.78.119,000217194781
5TXCB003AS3 · cold climateA951X080BD4SA15.211.78.119,000217194782
5TXCC005AS3 · cold climateA951X080CU5SA15.211.78.119,000217194784
5TXCB003AS3 · cold climateA951X080BU4SA15.211.78.119,000217194783
5TXCC005AS3 · cold climateA951X100CD5SA15.211.78.119,000217194785
5TXCB003AS3 · cold climateA801X060BM4SD15.211.78.119,000217194773
5TXCB003AS3 · cold climateA801X080BM4SD15.211.78.119,000217194774
5TXCB003AS3 · cold climateA801X040AM3TD15.211.78.119,000217194775
5TXCB003AS3 · cold climateA801X060BM4TD15.211.78.119,000217194776
5TXCB003AS3 · cold climateA801X080BM4TD15.211.78.119,000217194777
5TXCB003AS3 · cold climateA951X040BD3SA15.211.78.119,000217194778
5TXCB003AS3 · cold climateA951X040BU3SA15.211.78.119,000217194779
5TXCB003AS3 · cold climateA951X060BD3SA15.211.78.119,000217194780
5TXCB003AS3 · cold climateL9X1B070U4VSA15.211.78.119,000217194752
5TXCB003AS3 · cold climateA801X040AM3SD15.211.78.119,000217194753
5TXCB003AS3 · cold climateA801X040BM2SD15.211.78.119,000217194754
5TXCB003AS3 · cold climateA801X040BM2TD15.211.78.119,000217194755
5TXCB003AS3 · cold climateA801X060BM4SD15.211.78.119,000217194756
5TXCB003AS3 · cold climateA801X040AM3TD15.211.78.119,000217194758
5TXCB003AS3 · cold climateA801X060BM4TD15.211.78.119,000217194759
5TXCB003AS3 · cold climateA801X080BM4TD15.211.78.119,000217194760
5TXCB003AS3 · cold climateA951X040BD3SA15.211.78.119,000217194761
5TXCB003AS3 · cold climateA951X040BU3SA15.211.78.119,000217194762
5TXCB003AS3 · cold climateA951X060BD3SA15.211.78.119,000217194763
5TXCB003AS3 · cold climateA951X060BU4SA15.211.78.119,000217194764
5TXCB003AS3 · cold climateA951X080BU4SA15.211.78.119,000217194766
5TXCC005AS3 · cold climateA951X100CD5SA15.211.78.119,000217194768
5TXCB003AS3 · cold climateL9X1B070U4VSA15.211.78.119,000217194769
5TXCB003AS3 · cold climateA801X040BM2SD15.211.78.119,000217194771
5TXCB003AS3 · cold climateA801X040BM2TD15.211.78.119,000217194772
5TXCB003AS3 · cold climateA801X080BM4SD15.211.78.119,000217194757
5TXCB003AS3 · cold climateA951X080BD4SA15.211.78.119,000217194765
5TXCC005AS3 · cold climateA951X080CU5SA15.211.78.119,000217194767
5TXCB003AS3 · cold climateA801X040AM3SD15.211.78.119,000217194770
5PXCBD03AS3+P0V0B000M40SD · cold climate-15.211.78.119,000217512472
5TXCB003AS3+P0V0B000M40SD · cold climate-15.211.78.119,000217512473
5PXCBD03AS3+P0V0B000M40SD · cold climate-15.211.78.119,000217512478
5TXCB003AS3+P0V0B000M40SD · cold climate-15.211.78.119,000217512479
Yearly running cost in 10 large cities$618-$1,703

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the RunTru A5HL5024A1?
The RunTru A5HL5024A1 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 40 certified matchups SEER2 ranges from 15.2-16.0.
Is the RunTru A5HL5024A1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the RunTru A5HL5024A1 cost to run per year?
At its rated efficiency it costs about $618-$1,703 a year in electricity in large U.S. cities, depending on climate and local rates - for example $768 in Phoenix and $1,428 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the RunTru A5HL5024A1?
ENERGY STAR lists 40 certified combinations for this outdoor unit. The highest-rated ones use A5AHV002A1B3, 5TXCB003AS3, 5TXCC005AS3.
What refrigerant does the RunTru A5HL5024A1 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $766/yrYou save $333/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump RunTru A5HL5024A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$766
Current system, per year
$1,099
You save per year
$333
Payback
24.0 years
Net after 10 years
-$4,670

Cooling $462Heating $304Electricity used: 4,789 kWhSaved vs. a minimum-efficiency heat pump: $79

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 23, 2025. How we use the data.