HVAC Rated

2-ton central heat pump · T* Series

UTL UCHA-24HDCTN2

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #27 of 331 2 ton central heat pumps for cooling efficiency, and costs about $654 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
17,800 BTU/h74% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,800 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-32
General
BrandUTL
Also sold asVillaTherm, MDX, Bestcold
Outdoor unit modelUCHA-24HDCTN2
SeriesT* Series
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceSeptember 11, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 20.0)
EER2Efficiency at 95°F outdoors14.0
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5
Capacity at 47°F24,000 BTU/h
Capacity at 17°F15,800 BTU/h
Capacity at 5°F17,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.20
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UCHA-24HDCN2 at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
UCHA-24HDCN2 · cold climate20.014.09.517,800218775059
Same unit, other model numbers4

These model numbers have exactly the same certified ratings and matchups as the UTL UCHA-24HDCTN2: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$565-$1,579

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the UTL UCHA-24HDCTN2?
The UTL UCHA-24HDCTN2 is rated at up to 20.0 SEER2 and 14.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the UTL UCHA-24HDCTN2 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,800 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the UTL UCHA-24HDCTN2 cost to run per year?
At its rated efficiency it costs about $565-$1,579 a year in electricity in large U.S. cities, depending on climate and local rates - for example $706 in Phoenix and $1,326 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the UTL UCHA-24HDCTN2 the same as the VillaTherm VHP-UCA-24HDC-A?
Yes, as far as the certified ratings go. ENERGY STAR lists 5 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the UTL UCHA-24HDCTN2?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses UCHA-24HDCN2.
What refrigerant does the UTL UCHA-24HDCTN2 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $705/yrYou save $532/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump UTL UCHA-24HDCTN2
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$705
Current system, per year
$1,238
You save per year
$532
Payback
16.9 years
Net after 10 years
-$3,678

Cooling $422Heating $283Electricity used: 4,408 kWhSaved vs. a minimum-efficiency heat pump: $244

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.