2-ton central heat pump · 4SHP17LE SERIES
Armstrong Air 4SHP17LE124P-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #231 of 331 2 ton central heat pumps for cooling efficiency, and costs about $706 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 11,500 BTU/h47% of its 47°F outputVery good · beats 70%
A good fit if…
- You want a choice of indoor units - 635 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | AIREASE |
| Outdoor unit model | 4SHP17LE124P-**A |
| Series | 4SHP17LE SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 25, 2022 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.2-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,400-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 21,000-22,600 BTU/h |
| Capacity at 17°F | 13,400-14,700 BTU/h |
| Capacity at 5°F | 10,200-11,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.16 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAH1P30B*+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 635 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EAH1P30B*+TDR+TXV | A80UH2E090B16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735155 |
| EAH1P30B*+TDR+TXV | A80UH2E090B16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735156 |
| EAH1P30B*+TDR+TXV | A80UH1E090B16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735237 |
| EAH1P30B*+TDR+TXV | A80UH1E090B16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735239 |
| EAH1P30B*+TDR+TXV | A80US2V090B12 | 17.0 | 14.0 | 8.0 | 10,400 | 211735337 |
| 7EH30BX-0*+TDR | A80US2V090B12 | 17.0 | 14.0 | 8.0 | 10,400 | 214713817 |
| 7EH30BX-0*+TDR | A80UH1E090B16 | 17.0 | 14.0 | 8.0 | 10,400 | 214713809 |
| 7EH30BX-0*+TDR | A80UH2E090B16 | 17.0 | 14.0 | 8.0 | 10,300 | 214713803 |
| 7EH30BX-0*+TDR | A80UH1E090B16 | 17.0 | 14.0 | 8.0 | 10,400 | 214715302 |
| 7EH30BX-0*+TDR | A80US2V090B12 | 17.0 | 14.0 | 8.0 | 10,400 | 214715310 |
| 7EH30BX-0*+TDR | A80UH2E090B16 | 17.0 | 14.0 | 8.0 | 10,300 | 214715296 |
| EAH1P30B*+TDR+TXV | A80US2V090B12 | 17.0 | 14.0 | 8.0 | 10,400 | 211735339 |
| EAH1P30A*+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 10,400 | 211735103 |
| EAH1P30A*+TDR+TXV | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 10,400 | 211735102 |
| 7EH30AX-0*+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 10,400 | 214713797 |
| 7EH30AX-0*+TDR | A80US2V060A12X | 16.8 | 14.0 | 8.1 | 10,400 | 214715290 |
| EAH1P30B*+TDR+TXV | A80UH1E070B12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735220 |
| EAH1P30B*+TDR+TXV | A80UH1E070B12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735222 |
| EAH1P30B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.0 | 10,400 | 211735335 |
| 7EH30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.0 | 10,400 | 214713816 |
| 7EH30BX-0*+TDR | A80UH1E070B12 | 16.8 | 13.5 | 8.0 | 10,400 | 214713808 |
| 7EH30BX-0*+TDR | A80UH1E070B12 | 16.8 | 13.5 | 8.0 | 10,400 | 214715301 |
| 7EH30BX-0*+TDR | A80US2V080B16X | 16.8 | 14.0 | 8.0 | 10,400 | 214715309 |
| EAH1P30B*+TDR+TXV | A80US2V080B16X | 16.8 | 14.0 | 8.0 | 10,400 | 211735333 |
| EAH1P30B*+TDR+TXV | A80UH2E090B12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735146 |
| EAH1P30B*+TDR+TXV | A80UH2E090B12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735144 |
| EAH1P30B*+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 211735366 |
| EAH1P30B*+TDR+TXV | A97USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 211735364 |
| EAH1P30B*+TDR+TXV | A98USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 213805277 |
| EAH1P30B*+TDR+TXV | A98USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 213805276 |
| EAH1P30B+TDR+TXV | A97US2V070B12S | 16.8 | 13.5 | 7.8 | 10,400 | 214074512 |
| EAH1P30B+TDR+TXV | A97US2V070B12S | 16.8 | 13.5 | 7.8 | 10,400 | 214074764 |
| 7EH30BX-0*+TDR | A97US2V070B12S* | 16.8 | 13.5 | 7.8 | 10,400 | 214713807 |
| 7EH30BX-0*+TDR | A97USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 214713821 |
| 7EH30BX-0*+TDR | A80UH2E090B12 | 16.8 | 13.5 | 7.8 | 10,300 | 214713802 |
| 7EH30BX-0*+TDR | A97USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 214715314 |
| 7EH30BX-0*+TDR | A80UH2E090B12 | 16.8 | 13.5 | 7.8 | 10,300 | 214715295 |
| 7EH30BX-0*+TDR | A97US2V070B12S* | 16.8 | 13.5 | 7.8 | 10,400 | 214715300 |
| 7EH30BX-0*+TDR | A98USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 214780523 |
| 7EH30BX-0*+TDR | A98USMV070B12 | 16.8 | 13.5 | 7.8 | 10,400 | 214780400 |
| EAH1P30A*+TDR+TXV | A80UH2E045A12 | 16.6 | 13.5 | 8.1 | 10,400 | 211735049 |
| EAH1P30A*+TDR+TXV | A80UH2E045A12 | 16.6 | 13.5 | 8.1 | 10,400 | 211735048 |
| 7EH30AX-0*+TDR | A80UH2E045A12 | 16.6 | 13.5 | 8.1 | 10,400 | 214713793 |
| 7EH30AX-0*+TDR | A80UH2E045A12 | 16.6 | 13.5 | 8.1 | 10,400 | 214715286 |
| EA(C;U)1P30B+TDR+TXV | A80US2V090B12 | 16.6 | 13.5 | 8.0 | 10,400 | 211662902 |
| EA(C;U)1P30B+TDR+TXV | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 211662894 |
| EA(C;U)1P30B+TDR+TXV | A80US2V090B12 | 16.6 | 13.5 | 8.0 | 10,400 | 211662384 |
| EA(C;U)1P30B+TDR+TXV | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 211662376 |
| EAC4X30A+TDR | A80US2V060A12X | 16.6 | 13.5 | 8.0 | 10,200 | 211662954 |
| EAC4X30B+TDR | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 211662965 |
| EAC4X30B+TDR | A80US2V090B12 | 16.6 | 13.5 | 8.0 | 10,400 | 211662455 |
| EAC4X30B+TDR | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 211662447 |
| EA(C;U)1P30A+TDR+TXV | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 210329517 |
| EA(C;U)1P30A+TDR+TXV | A80UH1E090B16 | 16.6 | 13.5 | 8.0 | 10,400 | 210330127 |
| EA(C;U)1P30A+TDR+TXV | A80US2V060A12X | 16.6 | 13.5 | 8.0 | 10,200 | 210330108 |
| EA(C;U)1P30A+TDR+TXV | A80US2V090B12 | 16.6 | 13.5 | 8.0 | 10,400 | 210329510 |
| EA(C;U)1P30A+TDR+TXV | A80US2V090B12 | 16.6 | 13.5 | 8.0 | 10,400 | 210330120 |
| EA(C;U)1P30A+TDR+TXV | A80US2V060A12X | 16.6 | 13.5 | 8.0 | 10,200 | 210329498 |
| EAC4X30A+TDR | A80US2V060A12X | 16.6 | 13.5 | 8.0 | 10,200 | 211662436 |
| EAH1P30B*+TDR+TXV | A93UH1E070B12 | 16.6 | 13.5 | 8.0 | 10,600 | 211735282 |
Yearly running cost in 10 large cities
- Phoenix, AZ$789/yr
- Miami, FL$646/yr
- Houston, TX$707/yr
- Atlanta, GA$706/yr
- Los Angeles, CA$685/yr
- New York, NY$1,676/yr
- Chicago, IL$1,359/yr
- Denver, CO$1,128/yr
- Seattle, WA$692/yr
- Minneapolis, MN$1,395/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air 4SHP17LE124P-**A?
- The Armstrong Air 4SHP17LE124P-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 635 certified matchups SEER2 ranges from 15.2-17.0.
- Is the Armstrong Air 4SHP17LE124P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Armstrong Air 4SHP17LE124P-**A cost to run per year?
- At its rated efficiency it costs about $646-$1,676 a year in electricity in large U.S. cities, depending on climate and local rates - for example $789 in Phoenix and $1,395 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air 4SHP17LE124P-**A?
- ENERGY STAR lists 635 certified combinations for this outdoor unit. The highest-rated ones use EAH1P30B*+TDR+TXV, 7EH30BX-0*+TDR, EAH1P30A*+TDR+TXV.
- What refrigerant does the Armstrong Air 4SHP17LE124P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Daikin DZ6VSA241EA · cold climate17.0 SEER2 · 8.6 HSPF2
- Blueridge BHP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Continental WSEHV2436RA1-C · cold climate17.0 SEER2 · 9.0 HSPF2
- Comfort-Aire HRG1524S1R-**A17.0 SEER2 · 8.2 HSPF2
- AC Pro AUD36W/A-D(U) · cold climate17.0 SEER2 · 9.0 HSPF2
- Concord 4HP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Trane 5HCL5024A1 · cold climate17.0 SEER2 · 9.2 HSPF2
- GE NS17H24SA4-**A17.0 SEER2 · 8.2 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.