HVAC Rated

2-ton central heat pump · 4SHP17LE SERIES

Armstrong Air 4SHP17LE124P-**A

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #231 of 331 2 ton central heat pumps for cooling efficiency, and costs about $706 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.2 Heating efficiency over a season
Below average · beats 28%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
11,500 BTU/h47% of its 47°F output
Very good · beats 70%

A good fit if…

  • You want a choice of indoor units - 635 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandArmstrong Air
Also sold asAIREASE
Outdoor unit model4SHP17LE124P-**A
Series4SHP17LE SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 25, 2022
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors12.5-14.0
Cooling capacity22,400-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.2
Capacity at 47°F21,000-22,600 BTU/h
Capacity at 17°F13,400-14,700 BTU/h
Capacity at 5°F10,200-11,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.16
ENERGY STAR cold climateNo
Heating output as it gets colder47% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAH1P30B*+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups635 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 635 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EAH1P30B*+TDR+TXVA80UH2E090B1617.014.08.010,300211735155
EAH1P30B*+TDR+TXVA80UH2E090B1617.014.08.010,300211735156
EAH1P30B*+TDR+TXVA80UH1E090B1617.014.08.010,400211735237
EAH1P30B*+TDR+TXVA80UH1E090B1617.014.08.010,400211735239
EAH1P30B*+TDR+TXVA80US2V090B1217.014.08.010,400211735337
7EH30BX-0*+TDRA80US2V090B1217.014.08.010,400214713817
7EH30BX-0*+TDRA80UH1E090B1617.014.08.010,400214713809
7EH30BX-0*+TDRA80UH2E090B1617.014.08.010,300214713803
7EH30BX-0*+TDRA80UH1E090B1617.014.08.010,400214715302
7EH30BX-0*+TDRA80US2V090B1217.014.08.010,400214715310
7EH30BX-0*+TDRA80UH2E090B1617.014.08.010,300214715296
EAH1P30B*+TDR+TXVA80US2V090B1217.014.08.010,400211735339
EAH1P30A*+TDR+TXVA80US2V060A12X16.814.08.110,400211735103
EAH1P30A*+TDR+TXVA80US2V060A12X16.814.08.110,400211735102
7EH30AX-0*+TDRA80US2V060A12X16.814.08.110,400214713797
7EH30AX-0*+TDRA80US2V060A12X16.814.08.110,400214715290
EAH1P30B*+TDR+TXVA80UH1E070B1216.813.58.010,400211735220
EAH1P30B*+TDR+TXVA80UH1E070B1216.813.58.010,400211735222
EAH1P30B*+TDR+TXVA80US2V080B16X16.814.08.010,400211735335
7EH30BX-0*+TDRA80US2V080B16X16.814.08.010,400214713816
7EH30BX-0*+TDRA80UH1E070B1216.813.58.010,400214713808
7EH30BX-0*+TDRA80UH1E070B1216.813.58.010,400214715301
7EH30BX-0*+TDRA80US2V080B16X16.814.08.010,400214715309
EAH1P30B*+TDR+TXVA80US2V080B16X16.814.08.010,400211735333
EAH1P30B*+TDR+TXVA80UH2E090B1216.813.57.810,300211735146
EAH1P30B*+TDR+TXVA80UH2E090B1216.813.57.810,300211735144
EAH1P30B*+TDR+TXVA97USMV070B1216.813.57.810,400211735366
EAH1P30B*+TDR+TXVA97USMV070B1216.813.57.810,400211735364
EAH1P30B*+TDR+TXVA98USMV070B1216.813.57.810,400213805277
EAH1P30B*+TDR+TXVA98USMV070B1216.813.57.810,400213805276
EAH1P30B+TDR+TXVA97US2V070B12S16.813.57.810,400214074512
EAH1P30B+TDR+TXVA97US2V070B12S16.813.57.810,400214074764
7EH30BX-0*+TDRA97US2V070B12S*16.813.57.810,400214713807
7EH30BX-0*+TDRA97USMV070B1216.813.57.810,400214713821
7EH30BX-0*+TDRA80UH2E090B1216.813.57.810,300214713802
7EH30BX-0*+TDRA97USMV070B1216.813.57.810,400214715314
7EH30BX-0*+TDRA80UH2E090B1216.813.57.810,300214715295
7EH30BX-0*+TDRA97US2V070B12S*16.813.57.810,400214715300
7EH30BX-0*+TDRA98USMV070B1216.813.57.810,400214780523
7EH30BX-0*+TDRA98USMV070B1216.813.57.810,400214780400
EAH1P30A*+TDR+TXVA80UH2E045A1216.613.58.110,400211735049
EAH1P30A*+TDR+TXVA80UH2E045A1216.613.58.110,400211735048
7EH30AX-0*+TDRA80UH2E045A1216.613.58.110,400214713793
7EH30AX-0*+TDRA80UH2E045A1216.613.58.110,400214715286
EA(C;U)1P30B+TDR+TXVA80US2V090B1216.613.58.010,400211662902
EA(C;U)1P30B+TDR+TXVA80UH1E090B1616.613.58.010,400211662894
EA(C;U)1P30B+TDR+TXVA80US2V090B1216.613.58.010,400211662384
EA(C;U)1P30B+TDR+TXVA80UH1E090B1616.613.58.010,400211662376
EAC4X30A+TDRA80US2V060A12X16.613.58.010,200211662954
EAC4X30B+TDRA80UH1E090B1616.613.58.010,400211662965
EAC4X30B+TDRA80US2V090B1216.613.58.010,400211662455
EAC4X30B+TDRA80UH1E090B1616.613.58.010,400211662447
EA(C;U)1P30A+TDR+TXVA80UH1E090B1616.613.58.010,400210329517
EA(C;U)1P30A+TDR+TXVA80UH1E090B1616.613.58.010,400210330127
EA(C;U)1P30A+TDR+TXVA80US2V060A12X16.613.58.010,200210330108
EA(C;U)1P30A+TDR+TXVA80US2V090B1216.613.58.010,400210329510
EA(C;U)1P30A+TDR+TXVA80US2V090B1216.613.58.010,400210330120
EA(C;U)1P30A+TDR+TXVA80US2V060A12X16.613.58.010,200210329498
EAC4X30A+TDRA80US2V060A12X16.613.58.010,200211662436
EAH1P30B*+TDR+TXVA93UH1E070B1216.613.58.010,600211735282
Yearly running cost in 10 large cities$646-$1,676

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Armstrong Air 4SHP17LE124P-**A?
The Armstrong Air 4SHP17LE124P-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 635 certified matchups SEER2 ranges from 15.2-17.0.
Is the Armstrong Air 4SHP17LE124P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Armstrong Air 4SHP17LE124P-**A cost to run per year?
At its rated efficiency it costs about $646-$1,676 a year in electricity in large U.S. cities, depending on climate and local rates - for example $789 in Phoenix and $1,395 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Armstrong Air 4SHP17LE124P-**A?
ENERGY STAR lists 635 certified combinations for this outdoor unit. The highest-rated ones use EAH1P30B*+TDR+TXV, 7EH30BX-0*+TDR, EAH1P30A*+TDR+TXV.
What refrigerant does the Armstrong Air 4SHP17LE124P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $780/yrYou save $398/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Armstrong Air 4SHP17LE124P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$780
Current system, per year
$1,177
You save per year
$398
Payback
22.6 years
Net after 10 years
-$5,024

Cooling $485Heating $295Electricity used: 4,872 kWhSaved vs. a minimum-efficiency heat pump: $119

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.