2-ton central heat pump · 4HP17L SERIES
Concord 4HP17L24P-**A
Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #234 of 331 2 ton central heat pumps for cooling efficiency, and costs about $706 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 8.2 Heating efficiency over a seasonBelow average · beats 28%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 11,500 BTU/h47% of its 47°F outputVery good · beats 71%
A good fit if…
- You want a choice of indoor units - 1,372 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
- Comfort and noise matter - a single-stage compressor runs only full-on or off.
Details
Specifications
| General | |
|---|---|
| Brand | Concord |
| Also sold as | AC Pro, ALLIED, Ducane, Breeze33, ROYALTON |
| Outdoor unit model | 4HP17L24P-**A |
| Series | 4HP17L SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 25, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 15.4-17.0) |
| EER2Efficiency at 95°F outdoors | 12.5-14.0 |
| Cooling capacity | 22,400-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.2 |
| Capacity at 47°F | 21,000-22,600 BTU/h |
| Capacity at 17°F | 13,400-14,700 BTU/h |
| Capacity at 5°F | 10,200-11,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.18 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EAH1P30B*+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,372 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EAH1P30B*+TDR+TXV | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735153 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 211735158 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 211735159 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735150 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735147 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735149 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 211735157 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 211735160 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 211735151 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 211735161 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735235 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735224 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735231 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735230 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 211735233 |
| EAH1P30B*+TDR+TXV | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 213315438 |
| 7EH30BX-0*+TDR | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214710334 |
| 7EH30BX-0*+TDR | 80G1UH090BE16L | 17.0 | 14.0 | 8.0 | 10,400 | 214710335 |
| 7EH30BX-0*+TDR | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214711215 |
| 7EH30BX-0*+TDR | 80G1UH090BE16L | 17.0 | 14.0 | 8.0 | 10,400 | 214711216 |
| 7EH30BX-0*+TDR | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214711207 |
| 7EH30BX-0*+TDR | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 214711208 |
| 7EH30BX-0*+TDR | 80G1UH090BE16L | 17.0 | 14.0 | 8.0 | 10,400 | 214712097 |
| 7EH30BX-0*+TDR | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214712088 |
| 7EH30BX-0*+TDR | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 214712089 |
| 7EH30BX-0*+TDR | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214712096 |
| 7EH30BX-0*+TDR | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214708572 |
| 7EH30BX-0*+TDR | 80G1UH090BE16L | 17.0 | 14.0 | 8.0 | 10,400 | 214708573 |
| 7EH30BX-0*+TDR | 80G1UH090BE16L | 17.0 | 14.0 | 8.0 | 10,400 | 214709454 |
| 7EH30BX-0*+TDR | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214710326 |
| 7EH30BX-0*+TDR | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 214710327 |
| 7EH30BX-0*+TDR | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214709445 |
| 7EH30BX-0*+TDR | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 214709446 |
| 7EH30BX-0*+TDR | 80G1UH090BE16 | 17.0 | 14.0 | 8.0 | 10,400 | 214709453 |
| 7EH30BX-0*+TDR | 80G2UH090BE16L | 17.0 | 14.0 | 8.0 | 10,300 | 214708565 |
| 7EH30BX-0*+TDR | 80G2UH090BE16 | 17.0 | 14.0 | 8.0 | 10,300 | 214708564 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735208 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735218 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735216 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735212 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 213315436 |
| 7EH30BX-0*+TDR | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214710332 |
| 7EH30BX-0*+TDR | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214711213 |
| 7EH30BX-0*+TDR | 80G1UH070BE12L | 16.8 | 13.5 | 8.0 | 10,400 | 214711214 |
| 7EH30BX-0*+TDR | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214712094 |
| 7EH30BX-0*+TDR | 80G1UH070BE12L | 16.8 | 13.5 | 8.0 | 10,400 | 214712095 |
| 7EH30BX-0*+TDR | 80G1UH070BE12L | 16.8 | 13.5 | 8.0 | 10,400 | 214710333 |
| 7EH30BX-0*+TDR | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214708570 |
| 7EH30BX-0*+TDR | 80G1UH070BE12L | 16.8 | 13.5 | 8.0 | 10,400 | 214708571 |
| 7EH30BX-0*+TDR | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 214709451 |
| 7EH30BX-0*+TDR | 80G1UH070BE12L | 16.8 | 13.5 | 8.0 | 10,400 | 214709452 |
| EAH1P30B*+TDR+TXV | 80G1UH070BE12 | 16.8 | 13.5 | 8.0 | 10,400 | 211735214 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735141 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735138 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735135 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735140 |
| EAH1P30B*+TDR+TXV | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 211735142 |
| 7EH30BX-0*+TDR | 97G2UH070BV12 | 16.8 | 13.5 | 7.8 | 10,400 | 214710331 |
| 7EH30BX-0*+TDR | 97G2UH070BV12 | 16.8 | 13.5 | 7.8 | 10,400 | 214711212 |
| 7EH30BX-0*+TDR | 80G2UH090BE12 | 16.8 | 13.5 | 7.8 | 10,300 | 214711206 |
Yearly running cost in 10 large cities
- Phoenix, AZ$789/yr
- Miami, FL$646/yr
- Houston, TX$707/yr
- Atlanta, GA$706/yr
- Los Angeles, CA$685/yr
- New York, NY$1,676/yr
- Chicago, IL$1,359/yr
- Denver, CO$1,128/yr
- Seattle, WA$692/yr
- Minneapolis, MN$1,395/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Concord 4HP17L24P-**A?
- The Concord 4HP17L24P-**A is rated at up to 17.0 SEER2 and 14.0 EER2 for cooling and up to 8.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1372 certified matchups SEER2 ranges from 15.4-17.0.
- Is the Concord 4HP17L24P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Concord 4HP17L24P-**A cost to run per year?
- At its rated efficiency it costs about $646-$1,676 a year in electricity in large U.S. cities, depending on climate and local rates - for example $789 in Phoenix and $1,395 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Concord 4HP17L24P-**A?
- ENERGY STAR lists 1372 certified combinations for this outdoor unit. The highest-rated ones use EAH1P30B*+TDR+TXV, 7EH30BX-0*+TDR.
- What refrigerant does the Concord 4HP17L24P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Comfort-Aire HRG1524S1R-**A17.0 SEER2 · 8.2 HSPF2
- GE NS17H24SA4-**A17.0 SEER2 · 8.2 HSPF2
- Blueridge BHP17L24P-**A17.0 SEER2 · 8.2 HSPF2
- Lennox EL17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Armstrong Air 4SHP17LE124P-**A17.0 SEER2 · 8.2 HSPF2
- Lennox ML17XP1-024-230A17.0 SEER2 · 8.2 HSPF2
- Daikin DZ6VSA241EA · cold climate17.0 SEER2 · 8.6 HSPF2
- Trane 5TWR6024A117.0 SEER2 · 8.1 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.