HVAC Rated

3.5-ton central heat pump · 4SHP17LE SERIES

Armstrong Air 4SHP17LE142P-**A

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #88 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,294 a year to run in a mixed climate like Atlanta.

SEER2
15.6 Cooling efficiency over a season
Below average · beats 17%
HSPF2
8.3 Heating efficiency over a season
Below average · beats 30%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
22,000 BTU/h55% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want a choice of indoor units - 170 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3.5 ton, R-410A
General
BrandArmstrong Air
Also sold asAIREASE
Outdoor unit model4SHP17LE142P-**A
Series4SHP17LE SERIES
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 10, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.6 (range 15.2-15.6)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity40,000-42,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.3
Capacity at 47°F37,600-42,000 BTU/h
Capacity at 17°F25,000-27,600 BTU/h
Capacity at 5°F10,400-22,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.20
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BCE7E42M*4X at the standard test temperatures, in BTU/h:

Certified matchups170 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 170 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BCE7E42M*4X-15.613.08.322,000210329181
BCE7E42M*4X-15.613.08.322,000210329791
BCE7S42M*4X-15.613.08.320,600210329792
BCE7S42M*4X-15.613.08.320,600210329182
EAD4X-48C+TDRA80DF1E110C2015.613.08.321,800213264990
EAD4X-48C+TDRA80DF1E110C2015.613.08.321,800213264864
7ED48CX-0*+TDRA80DF1E110C2015.613.08.321,800214714362
7ED48CX-0*+TDRA80DF1E110C2015.613.08.321,800214715855
7AH2AE42PX-0-15.613.08.322,000214865857
7AH2AE42PX-0-15.613.08.322,000214866002
EA(C;U)1P49C+TDR+TXVA80US2V100C20X15.613.07.819,900210329195
EA(C;U)1P49C+TDR+TXVA80US2V100C20X15.613.07.819,900210329805
EAC4X49C+TDRA80US2V100C20X15.613.07.819,900211663200
EAC4X49C+TDRA80US2V100C20X15.613.07.819,900211662682
7EC48CX-0*+TDRA80UH2E110C1615.613.07.819,600214714390
7EH42BX-0*+TDRA80UH2E090B1615.613.07.819,900214714269
7EC48CX-0*+TDRA80US2V080C20X15.613.07.819,700214714407
7EC49CX-0*+TDRA80US2V100C20X15.613.07.819,900214714438
7EC48CX-0*+TDRA80UH2E110C1615.613.07.819,600214715883
7EC48CX-0*+TDRA80UH2E110C2015.613.07.819,600214715884
7EC48CX-0*+TDRA80US2V080C20X15.613.07.819,700214715900
7EC48CX-0*+TDRA80US2V100C20X15.613.07.819,700214715902
7EC48CX-0*+TDRA80US2V100C20X15.613.07.819,700214714409
7EH42BX-0*+TDRA80UH2E090B1615.613.07.819,900214715762
7EC48CX-0*+TDRA80UH2E110C2015.613.07.819,600214714391
7EC49CX-0*+TDRA80US2V100C20X15.613.07.819,900214715931
EAD4X-48C+TDRA80DS2V110C2015.413.08.322,000213264992
EAD4X-48C+TDRA80DS2V110C2015.413.08.322,000213264866
7ED48CX-0*+TDRA80DS2V110C2015.413.08.322,000214715859
7ED48CX-0*+TDRA80DS2V110C2015.413.08.322,000214714366
BCE5V42M*4X-15.413.08.120,200210329183
BCE5V42M*4X-15.413.08.120,200210329793
7AH1AV42PX-0-15.413.08.120,200214866000
7AH1AV42PX-0-15.413.08.120,200214865855
7EH42BX-0*+TDRA80US2V080B16X15.413.08.020,200214715771
7EH42BX-0*+TDRA80US2V080B16X15.413.08.020,200214714278
EA(C;U)1P49C+TDR+TXVA80UH2E110C2015.413.07.819,900210329798
EA(C;U)1P49C+TDR+TXVA80US2V080C20X15.413.07.819,900210329196
EAC4X49C+TDRA80UH2E110C2015.413.07.819,900211663188
EAC4X49C+TDRA80UH2E110C1615.413.07.819,600211663187
EA(C;U)1P49C+TDR+TXVA80UH1E110C2015.412.57.819,800210329795
EA(C;U)1P49C+TDR+TXVA93UH1E110C1615.412.57.819,800210329191
EA(C;U)1P49C+TDR+TXVA80UH2E110C1615.413.07.819,600210329193
EA(C;U)1P49C+TDR+TXVA93UH1E110C1615.412.57.819,800210329801
EAC4X49C+TDRA80UH1E110C2015.412.57.819,800211662674
EAC4X49C+TDRA93UH1E110C1615.412.57.819,800211662676
EAC4X49C+TDRA80US2V080C20X15.413.07.819,900211662680
EAC4X49C+TDRA80UH1E090C2015.412.57.819,800211663191
EAC4X49C+TDRA93UH1E110C1615.412.57.819,800211663194
EAC4X49C+TDRA80UH1E110C2015.412.57.819,800211663192
EAC4X49C+TDRA80US2V080C20X15.413.07.819,900211663198
EAC4X49C+TDRA80UH2E110C1615.413.07.819,600211662669
EAC4X49C+TDRA80UH2E110C2015.413.07.819,900211662670
EAC4X49C+TDRA80UH1E090C2015.412.57.819,800211662673
EA(C;U)1P49C+TDR+TXVA80UH2E110C2015.413.07.819,900210329188
EA(C;U)1P49C+TDR+TXVA80US2V080C20X15.413.07.819,900210329806
EA(C;U)1P49C+TDR+TXVA80UH1E110C2015.412.57.819,800210329185
EA(C;U)1P49C+TDR+TXVA80UH1E090C2015.412.57.819,800210329184
EA(C;U)1P49C+TDR+TXVA80UH2E110C1615.413.07.819,600210329803
EA(C;U)1P49C+TDR+TXVA80UH1E090C2015.412.57.819,800210329794
Yearly running cost in 10 large cities$1,231-$3,032

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Armstrong Air 4SHP17LE142P-**A?
The Armstrong Air 4SHP17LE142P-**A is rated at up to 15.6 SEER2 and 13.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 170 certified matchups SEER2 ranges from 15.2-15.6.
Is the Armstrong Air 4SHP17LE142P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Armstrong Air 4SHP17LE142P-**A cost to run per year?
At its rated efficiency it costs about $1,231-$3,032 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,482 in Phoenix and $2,506 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Armstrong Air 4SHP17LE142P-**A?
ENERGY STAR lists 170 certified combinations for this outdoor unit. The highest-rated ones use BCE7E42M*4X, BCE7S42M*4X, EAD4X-48C+TDR.
What refrigerant does the Armstrong Air 4SHP17LE142P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,451/yrYou save $630/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Armstrong Air 4SHP17LE142P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,451
Current system, per year
$2,081
You save per year
$630
Payback
24.6 years
Net after 10 years
-$9,201

Cooling $925Heating $526Electricity used: 9,071 kWhSaved vs. a minimum-efficiency heat pump: $140

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.