3.5-ton central heat pump · 4HP17L SERIES
Ducane 4HP17L42P-**A
Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.
Ranks #91 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,294 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.6 Cooling efficiency over a seasonBelow average · beats 17%
- HSPF2
- 8.3 Heating efficiency over a seasonBelow average · beats 30%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 22,000 BTU/h55% of its 47°F outputVery good · beats 76%
A good fit if…
- You want a choice of indoor units - 349 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Ducane |
| Also sold as | AC Pro, Concord, ALLIED, Breeze33, ROYALTON |
| Outdoor unit model | 4HP17L42P-**A |
| Series | 4HP17L SERIES |
| Type | Central heat pump |
| Nominal size | 3.5 ton |
| CompressorVariable-speed units run longer at low power | Single stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 10, 2022 |
| Last certified | October 27, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.6 (range 15.2-15.6) |
| EER2Efficiency at 95°F outdoors | 12.5-13.0 |
| Cooling capacity | 40,000-42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.3 |
| Capacity at 47°F | 37,600-42,000 BTU/h |
| Capacity at 17°F | 25,000-27,600 BTU/h |
| Capacity at 5°F | 19,600-22,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.02-2.20 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BCE7E42M*4X at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 349 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BCE7E42M*4X | - | 15.6 | 13.0 | 8.3 | 22,000 | 210325942 |
| BCE7E42M*4X | - | 15.6 | 13.0 | 8.3 | 22,000 | 210328426 |
| BCE7E42M*4X | - | 15.6 | 13.0 | 8.3 | 22,000 | 210327648 |
| BCE7E42M*4X | - | 15.6 | 13.0 | 8.3 | 22,000 | 210326870 |
| BCE7E42M*4X | - | 15.6 | 13.0 | 8.3 | 22,000 | 210324877 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213265153 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213265234 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213265072 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213265315 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213265396 |
| EAD4X-48C+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 213315759 |
| 7ED48CX-0*+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214709935 |
| 7ED48CX-0*+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214710816 |
| 7ED48CX-0*+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214711697 |
| 7ED48CX-0*+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214712578 |
| 7ED48CX-0*+TDR | 80G1DF110CE20 | 15.6 | 13.0 | 8.3 | 21,800 | 214709054 |
| 7AH2AE42PX-0 | - | 15.6 | 13.0 | 8.3 | 22,000 | 214865581 |
| 7AH2AE42PX-0 | - | 15.6 | 13.0 | 8.3 | 22,000 | 214865367 |
| 7AH2AE42PX-0 | - | 15.6 | 13.0 | 8.3 | 22,000 | 214865481 |
| 7AH2AE42PX-0 | - | 15.6 | 13.0 | 8.3 | 22,000 | 214865675 |
| 7AH2AE42PX-0 | - | 15.6 | 13.0 | 8.3 | 22,000 | 214865766 |
| 7EC48CX-0*+TDR | 80G2UH110CE16 | 15.6 | 13.0 | 7.8 | 19,600 | 214709960 |
| 7EC48CX-0*+TDR | 80G2UH110CE20 | 15.6 | 13.0 | 7.8 | 19,600 | 214709961 |
| 7EH42BX-0*+TDR | 80G2UH090BE16L | 15.6 | 13.0 | 7.8 | 19,900 | 214710743 |
| 7EH42BX-0*+TDR | 80G2UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214710742 |
| 7EC48CX-0*+TDR | 80G2UH110CE16 | 15.6 | 13.0 | 7.8 | 19,600 | 214710841 |
| 7EC48CX-0*+TDR | 80G2UH110CE20 | 15.6 | 13.0 | 7.8 | 19,600 | 214710842 |
| 7EH42BX-0*+TDR | 80G2UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214711623 |
| 7EH42BX-0*+TDR | 80G2UH090BE16L | 15.6 | 13.0 | 7.8 | 19,900 | 214711624 |
| 7EC48CX-0*+TDR | 80G2UH110CE16 | 15.6 | 13.0 | 7.8 | 19,600 | 214711722 |
| 7EC48CX-0*+TDR | 80G2UH110CE20 | 15.6 | 13.0 | 7.8 | 19,600 | 214711723 |
| 7EC48CX-0*+TDR | 80G2UH110CE20L | 15.6 | 13.0 | 7.8 | 19,600 | 214711724 |
| 7EC48CX-0*+TDR | 80G2UH110CE20L | 15.6 | 13.0 | 7.8 | 19,600 | 214712605 |
| 7EC48CX-0*+TDR | 80G2UH110CE16 | 15.6 | 13.0 | 7.8 | 19,600 | 214712603 |
| 7EC48CX-0*+TDR | 80G2UH110CE20 | 15.6 | 13.0 | 7.8 | 19,600 | 214712604 |
| 7EH42BX-0*+TDR | 80G2UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214712504 |
| 7EC48CX-0*+TDR | 80G2UH110CE20L | 15.6 | 13.0 | 7.8 | 19,600 | 214710843 |
| 7EH42BX-0*+TDR | 80G2UH090BE16L | 15.6 | 13.0 | 7.8 | 19,900 | 214712505 |
| 7EH42BX-0*+TDR | 80G2UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214708980 |
| 7EH42BX-0*+TDR | 80G2UH090BE16L | 15.6 | 13.0 | 7.8 | 19,900 | 214708981 |
| 7EC48CX-0*+TDR | 80G2UH110CE16 | 15.6 | 13.0 | 7.8 | 19,600 | 214709079 |
| 7EC48CX-0*+TDR | 80G2UH110CE20 | 15.6 | 13.0 | 7.8 | 19,600 | 214709080 |
| 7EC48CX-0*+TDR | 80G2UH110CE20L | 15.6 | 13.0 | 7.8 | 19,600 | 214709081 |
| 7EH42BX-0*+TDR | 80G2UH090BE16L | 15.6 | 13.0 | 7.8 | 19,900 | 214709862 |
| 7EC48CX-0*+TDR | 80G2UH110CE20L | 15.6 | 13.0 | 7.8 | 19,600 | 214709962 |
| 7EH42BX-0*+TDR | 80G2UH090BE16 | 15.6 | 13.0 | 7.8 | 19,900 | 214709861 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210324879 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210326872 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210327650 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210325944 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 210328428 |
| BCE5V42M*4X | - | 15.4 | 13.0 | 8.1 | 20,200 | 213315729 |
| 7AH1AV42PX-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214865579 |
| 7AH1AV42PX-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214865365 |
| 7AH1AV42PX-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214865479 |
| 7AH1AV42PX-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214865673 |
| 7AH1AV42PX-0 | - | 15.4 | 13.0 | 8.1 | 20,200 | 214865764 |
| EA(C;U)1P49C+TDR+TXV | 80G2UH110CE16 | 15.4 | 13.0 | 7.8 | 19,600 | 210324890 |
| EAC4X49C+TDR | 80G2UH110CE20 | 15.4 | 13.0 | 7.8 | 19,900 | 210327667 |
| EAC4X49C+TDR | 80G2UH110CE16 | 15.4 | 13.0 | 7.8 | 19,600 | 210324902 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,482/yr
- Miami, FL$1,231/yr
- Houston, TX$1,327/yr
- Atlanta, GA$1,294/yr
- Los Angeles, CA$1,248/yr
- New York, NY$3,032/yr
- Chicago, IL$2,450/yr
- Denver, CO$2,028/yr
- Seattle, WA$1,239/yr
- Minneapolis, MN$2,506/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Ducane 4HP17L42P-**A?
- The Ducane 4HP17L42P-**A is rated at up to 15.6 SEER2 and 13.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 349 certified matchups SEER2 ranges from 15.2-15.6.
- Is the Ducane 4HP17L42P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
- How much does the Ducane 4HP17L42P-**A cost to run per year?
- At its rated efficiency it costs about $1,231-$3,032 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,482 in Phoenix and $2,506 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Ducane 4HP17L42P-**A?
- ENERGY STAR lists 349 certified combinations for this outdoor unit. The highest-rated ones use BCE7E42M*4X, EAD4X-48C+TDR, 7ED48CX-0*+TDR.
- What refrigerant does the Ducane 4HP17L42P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3.5 ton models
- Comfort-Aire HRG1542S1R-**A15.6 SEER2 · 8.3 HSPF2
- GE NS17H42SA4-**A15.6 SEER2 · 8.3 HSPF2
- Blueridge BHP17L42P-**A15.6 SEER2 · 8.3 HSPF2
- Lennox EL17XP1-042-230A15.6 SEER2 · 8.3 HSPF2
- Armstrong Air 4SHP17LE142P-**A15.6 SEER2 · 8.3 HSPF2
- Lennox ML17XP1-042-230A15.6 SEER2 · 8.3 HSPF2
- York YH2F42TB2116.0 SEER2 · 8.1 HSPF2
- MRCOOL MHP17L42P-**A15.6 SEER2 · 8.3 HSPF2
See all 138 3.5 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.