3.5-ton central heat pump · ELITE EL17XP1 Series

Lennox EL17XP1-042-230A

Below average cooling and heating efficiency for a 3.5-ton central heat pump, but not rated for cold climates.

Ranks #93 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,300 a year to run in a mixed climate like Atlanta.

SEER2
15.6 Cooling efficiency over a season
Below average · beats 17%
HSPF2
8.3 Heating efficiency over a season
Below average · beats 30%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
22,000 BTU/h52% of its 47°F output
Very good · beats 80%

A good fit if…

  • You want a choice of indoor units - 188 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3.5 ton, R-410A
General
BrandLennox
Outdoor unit modelEL17XP1-042-230A
SeriesELITE EL17XP1 Series
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 10, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.6 (range 15.2-15.6)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity40,000-42,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.3
Capacity at 47°F37,600-42,000 BTU/h
Capacity at 17°F25,000-27,800 BTU/h
Capacity at 5°F10,400-22,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.22
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CBA38MV-042-230*+TDR at the standard test temperatures, in BTU/h:

Certified matchups188 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 188 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CBA38MV-042-230*+TDR-15.613.08.320,600210293753
CBA27UHE-042-230*+TDR-15.613.08.322,000210293752
CRX35-48C-**-*+TDRML180DF110E60C*15.613.08.321,800213257813
CK40DT-48C-0*+TDRML180DF110E60C*15.613.08.321,800214622738
CBK47UHET-042-230-0-15.613.08.322,000214861226
CX35-49C+TDRSL280UH100NV60C*15.613.07.819,900210293906
C35-49C+TDR+TXVSL280UH100NV60C*15.613.07.819,900210293742
CX35-49C+TDRML180UH110V60C*15.613.07.819,900210293892
C35-49C+TDR+TXVML180UH110V60C*15.613.07.819,900210293728
CK40CT-49C-0*+TDRML180UH110V60C*15.613.07.819,900214622767
CK40CT-49C-0*+TDRSL280UH100NV60C*15.613.07.819,900214622781
C35-48C+TDR+TXVEL280UH110E48C*15.613.07.819,600215223654
C35-48C+TDR+TXVEL280UH110E60C*15.613.07.819,600215223655
C35-48C+TDR+TXVEL280UH110XE60C*15.613.07.819,600215223656
C35-48C+TDR+TXVML180UH110V60C*15.613.07.819,700215223659
C35-48C+TDR+TXVSL280UH080NV60C*15.613.07.819,700215223666
C35-48C+TDR+TXVSL280UH100NV60C*15.613.07.819,700215223669
CHX35-42B-**-*+TDREL280UH090E48B*15.613.07.819,900215223674
CHX35-42B-**-*+TDREL280UH090XE48B*15.613.07.819,900215223675
CX35-48C+TDREL280UH110E48C*15.613.07.819,600215223689
CX35-48C+TDREL280UH110E60C*15.613.07.819,600215223690
CX35-48C+TDREL280UH110XE60C*15.613.07.819,600215223691
CX35-48C+TDRML180UH110V60C*15.613.07.819,700215223694
CX35-48C+TDRSL280UH080NV60C*15.613.07.819,700215223701
CX35-48C+TDRSL280UH100NV60C*15.613.07.819,700215223704
CK40HT-42B-0*+TDREL280UH090E48B*15.613.07.819,900215223760
CK40HT-42B-0*+TDREL280UH090XE48B*15.613.07.819,900215223761
CK40CT-48C-0*+TDREL280UH110E48C*15.613.07.819,600215223885
CK40CT-48C-0*+TDREL280UH110E60C*15.613.07.819,600215223886
CK40CT-48C-0*+TDREL280UH110XE60C*15.613.07.819,600215223887
CK40CT-48C-0*+TDRML180UH110V60C*15.613.07.819,700215223897
CK40CT-48C-0*+TDRSL280UH080NV60C*15.613.07.819,700215223909
CK40CT-48C-0*+TDRSL280UH100NV60C*15.613.07.819,700215223912
CRX35-48C-**-*+TDRSL280DF110V60C*15.413.08.322,000213257816
CK40DT-48C-0*+TDRSL280DF110V60C*15.413.08.322,000214622745
CBA25UHV-042-230--15.413.08.120,200210293751
CBK45UHVT-042-230-0-15.413.08.120,200214861225
CK40HT-42B-0*+TDRSL280UH080NV48B*15.413.08.020,200215223778
CHX35-42B-**-*+TDRML180UH070V48B*15.413.08.022,000215223678
CHX35-42B-**-*+TDRSL280UH080NV48B*15.413.08.020,200215223680
CK40HT-42B-0*+TDRML180UH070V48B*15.413.08.022,000215223767
C35-49C+TDR+TXVSL280UH080NV60C*15.413.07.819,900210293739
CX35-49C+TDRSL280UH080NV60C*15.413.07.819,900210293903
C35-49C+TDR+TXVML180UH110E60C*15.412.57.819,800210293727
C35-49C+TDR+TXVEL280UH110E48C*15.413.07.819,600210293716
CX35-49C+TDRML180UH110E60C*15.412.57.819,800210293891
CX35-49C+TDRML180UH090E60C*15.412.57.819,800210293890
C35-49C+TDR+TXVEL280UH110XE60C*15.413.07.819,900210293718
CHX35-48C-**-*+TDRSL280UH100NV60C*15.413.07.820,200210293825
CX35-49C+TDREL280UH110E60C*15.413.07.819,900210293881
CHX35-48C-**-*+TDRML180UH110V60C*15.413.07.810,400210293811
C35-49C+TDR+TXVML180UH090E60C*15.412.57.819,800210293726
CX35-49C+TDREL280UH110XE60C*15.413.07.819,900210293882
CX35-49C+TDREL280UH110E48C*15.413.07.819,600210293880
C35-49C+TDR+TXVEL280UH110E60C*15.413.07.819,900210293717
CK40HT-48C-0*+TDRML180UH110V60C*15.413.07.810,400214622710
CK40HT-48C-0*+TDRSL280UH100NV60C*15.413.07.820,200214622724
CK40CT-49C-0*+TDREL280UH110E48C*15.413.07.819,600214622755
CK40CT-49C-0*+TDREL280UH110E60C*15.413.07.819,900214622756
CK40CT-49C-0*+TDREL280UH110XE60C*15.413.07.819,900214622757
Yearly running cost in 10 large cities$1,240-$3,040

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL17XP1-042-230A?
The Lennox EL17XP1-042-230A is rated at up to 15.6 SEER2 and 13.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 188 certified matchups SEER2 ranges from 15.2-15.6.
Is the Lennox EL17XP1-042-230A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3.5-ton model.
How much does the Lennox EL17XP1-042-230A cost to run per year?
At its rated efficiency it costs about $1,240-$3,040 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,495 in Phoenix and $2,509 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL17XP1-042-230A?
ENERGY STAR lists 188 certified combinations for this outdoor unit. The highest-rated ones use CBA38MV-042-230*+TDR, CBA27UHE-042-230*+TDR, CRX35-48C-**-*+TDR.
What refrigerant does the Lennox EL17XP1-042-230A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,463/yrYou save $636/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL17XP1-042-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,463
Current system, per year
$2,099
You save per year
$636
Payback
24.4 years
Net after 10 years
-$9,137

Cooling $936Heating $526Electricity used: 9,142 kWhSaved vs. a minimum-efficiency heat pump: $141

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.