2.5-ton central heat pump · 15 SEER2 HP

Bryant PH5SAN531**AA

Below average cooling and heating efficiency for a 2.5-ton central heat pump, but not rated for cold climates.

Ranks #154 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $992 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
14,000 BTU/h45% of its 47°F output
Average · beats 51%

A good fit if…

  • You want a choice of indoor units - 112 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications2.5 ton, R-454B
General
BrandBryant
Also sold asPAYNE HEATING AND COOLING, WeatherMaker, BROCK
Outdoor unit modelPH5SAN531**AA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size2.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 31, 2025
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.7-13.0
Cooling capacity27,400-29,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F29,400-30,600 BTU/h
Capacity at 17°F17,500-18,200 BTU/h
Capacity at 5°F13,400-14,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.06
ENERGY STAR cold climateNo
Heating output as it gets colder45% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FJ5AN*C42L at the standard test temperatures, in BTU/h:

Certified matchups112 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 112 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FJ5AN*C42L-16.013.08.013,400217683350
PF5MN*C42L-16.013.08.013,400217683351
F55AA*C42L-16.013.08.013,400217683352
FJ5AN*C42L-16.013.08.013,400217683353
PF5MN*C42L-16.013.08.013,400217683354
PF5MN*C42L-16.013.08.013,400217683355
PF5MN*C42L-16.013.08.013,400217683356
FMA5X30**AL-16.013.08.013,700217683597
FMA5X30**AL-16.013.08.013,700217683598
FMA5X30**AL-16.013.08.013,700217683599
FMA5X30**AL-16.013.08.013,700217683600
FM(C,U)5Z36**AL-16.012.58.013,400217683502
FM(C,U)5Z36**AL-16.012.58.013,400217683501
FM(C,U)5Z36**AL-16.012.58.013,400217683503
FM(C,U)5Z36**AL-16.012.58.013,400217683504
FM(C,U)5Z30**AL-16.012.58.013,400217683469
FM(C,U)5Z30**AL-16.012.58.013,400217683470
FM(C,U)5Z30**AL-16.012.58.013,400217683471
FM(C,U)5Z30**AL-16.012.58.013,400217683472
FMA5X36**AL-16.013.08.013,700217683630
FMA5X36**AL-16.013.08.013,700217683629
FMA5X36**AL-16.013.08.013,700217683631
FMA5X36**AL-16.013.08.013,700217683632
FJ5AN*C42L-16.013.08.013,400218426623
CAA**3721AM935SB66100M21***15.512.08.014,000217680776
CAA**3721AM83*SB48060M17***15.512.08.014,000217680586
CAA**3721AM83*SB60080M21***15.512.58.014,000217680591
CAA**3721AM926TC66100V21***15.512.58.014,000217680839
CAA**3721AM927TA66100V21***15.512.58.014,000217680864
CAA**4321AM83*CB36040C17***15.512.58.013,900217680924
CAA**4321AM83*CB60080C21***15.512.58.013,900217680934
CAA**4321AM8(0,1)*SB60090M21***15.512.58.014,000217680974
CAA**4321AM8(0,1)*SB60110M21***15.512.58.014,000217680979
CAA**4321AM82*SB66110V21***15.512.58.014,000217680999
CAA**4321AM83*SB48060M17***15.512.08.014,000217681009
CAA**4321AM83*SB60080M21***15.512.58.014,000217681014
CAA**4321AM935SB66100M21***15.511.78.014,000217681199
CAA**4321AM926TC66100V21***15.513.08.014,000217681267
CAA**4321AM927TA66100V21***15.513.08.014,000217681292
CAA**3721AM83*CB36040C17***15.512.08.013,900217680506
CAA**3721AM83*CB60080C21***15.512.58.014,000217680516
CAA**3721AM8(0,1)*SB60090M21***15.512.58.014,000217680551
CAA**3721AM8(0,1)*SB60110M21***15.512.58.014,000217680556
CAA**3721AM82*SB66110V21***15.512.58.014,000217680576
CAA**3721AM912SE60080M21***15.512.58.014,000217680701
CAA**3721AM912SE60100M21***15.512.58.014,000217680706
CAA**3721AM912SE66100M21***15.512.58.014,000217680711
CAA**4321AM912SE60080M21***15.512.58.014,000217681124
CAA**4321AM912SE60100M21***15.512.58.014,000217681129
CAA**4321AM912SE66100M21***15.512.58.014,000217681134
CAA**3721AMPG92MSAA60080C**15.512.58.014,000217690823
CAA**3721AMPG92MSAA60080C**15.512.58.014,000217690824
CAA**3721AMPG92MSAA60080C**15.512.58.014,000217690825
CAA**3721AMPG92MSAA60100C**15.512.58.014,000217690846
CAA**3721AMPG92MSAA60100C**15.512.58.014,000217690847
CAA**3721AMPG92MSAA60100C**15.512.58.014,000217690848
CAA**3721AMPG80MS(A,L)A60090C**15.512.58.014,000217690161
CAA**3721AMPG80MS(A,L)A60090C**15.512.58.014,000217690162
CAA**3721AMPG80MS(A,L)A60090C**15.512.58.014,000217690163
CAA**3721AMPG80MS(A,L)A60110C**15.512.58.014,000217690186
Yearly running cost in 10 large cities$859-$2,393

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Bryant PH5SAN531**AA?
The Bryant PH5SAN531**AA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 112 certified matchups SEER2 ranges from 15.2-16.0.
Is the Bryant PH5SAN531**AA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2.5-ton model.
How much does the Bryant PH5SAN531**AA cost to run per year?
At its rated efficiency it costs about $859-$2,393 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,072 in Phoenix and $2,009 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Bryant PH5SAN531**AA?
ENERGY STAR lists 112 certified combinations for this outdoor unit. The highest-rated ones use FJ5AN*C42L, PF5MN*C42L, F55AA*C42L.
What refrigerant does the Bryant PH5SAN531**AA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,071/yrYou save $458/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Bryant PH5SAN531**AA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,071
Current system, per year
$1,529
You save per year
$458
Payback
24.0 years
Net after 10 years
-$6,423

Cooling $642Heating $428Electricity used: 6,693 kWhSaved vs. a minimum-efficiency heat pump: $105

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2.5 ton models

See all 199 2.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.