HVAC Rated

1.5-ton central heat pump · 15 SEER2 HP

Day & Night R5H5S19*K*AAA

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #128 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
8,500 BTU/h43% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 749 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandDay & Night
Also sold asKeeprite, Kenmore, Tempstar, Heil, Airquest, Arcoaire, Comfortmaker, Smart Comfort, MARATHERM, ACIQ
Outdoor unit modelR5H5S19*K*AAA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJanuary 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity17,700-19,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F18,400-19,500 BTU/h
Capacity at 17°F10,300-11,000 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder43% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FM(C,U)5Z30**AL at the standard test temperatures, in BTU/h:

Certified matchups749 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 749 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FM(C,U)5Z30**AL-16.013.08.08,100217687093
FM(C,U)5Z30**AL-16.013.08.08,100217687095
FM(C,U)5Z30**AL-16.013.08.08,100217687097
FM(C,U)5Z30**AL-16.013.08.08,100217687099
FM(C,U)5Z30**AL-16.013.08.08,100217687101
FM(C,U)5Z30**AL-16.013.08.08,100217687103
FM(C,U)5Z30**AL-16.013.08.08,100217687105
FM(C,U)5Z30**AL-16.013.08.08,100217687107
FM(C,U)5Z30**AL-16.013.08.08,100217687109
FM(C,U)5Z30**AL-16.013.08.08,100217687111
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705764
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705766
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705768
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705770
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705772
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705774
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705776
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705778
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705780
EA*5X25M17A*95MSU0601716A*16.012.58.08,400217705782
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705832
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705834
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705836
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705838
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705840
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705842
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705844
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705846
EA*5X25M17A*96CTN0801714B*16.013.08.08,300217705848
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702477
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702479
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702481
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702483
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702485
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702487
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702489
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702491
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702493
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217702495
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702502
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702504
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702506
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702508
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702510
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702514
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702512
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702516
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702518
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217702520
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704918
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704920
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704922
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704924
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704926
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704928
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704930
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704932
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704934
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217704936
EA*5X25M17A*80MS(N,L)0701412A*16.013.08.08,300217704968
Yearly running cost in 10 large cities$561-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Day & Night R5H5S19*K*AAA?
The Day & Night R5H5S19*K*AAA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 749 certified matchups SEER2 ranges from 15.2-16.0.
Is the Day & Night R5H5S19*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Day & Night R5H5S19*K*AAA cost to run per year?
At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Day & Night R5H5S19*K*AAA?
ENERGY STAR lists 749 certified combinations for this outdoor unit. The highest-rated ones use FM(C,U)5Z30**AL, EA*5X25M17A, EA*5X19M17A.
What refrigerant does the Day & Night R5H5S19*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $692/yrYou save $298/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Day & Night R5H5S19*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$692
Current system, per year
$990
You save per year
$298
Payback
23.5 years
Net after 10 years
-$4,020

Cooling $420Heating $272Electricity used: 4,324 kWhSaved vs. a minimum-efficiency heat pump: $68

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.