HVAC Rated

1.5-ton central heat pump · MAINLINE 16 SEER2 HP

Heil H5H6S19*K*AAA

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #131 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
8,500 BTU/h43% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 228 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandHeil
Also sold asAirquest, Arcoaire, Comfortmaker, Day & Night, Keeprite
Outdoor unit modelH5H6S19*K*AAA
SeriesMAINLINE 16 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 31, 2025
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity17,700-19,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F18,400-19,500 BTU/h
Capacity at 17°F10,300-11,000 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder43% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FM(C,U)5Z30**AL at the standard test temperatures, in BTU/h:

Certified matchups228 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 228 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FM(C,U)5Z30**AL-16.013.08.08,100217687303
EA*5X25M17A*80MSU0401712A*16.013.08.08,300217722520
EA*5X25M17A*80MSU0401712A*16.013.08.08,300217722521
EA*5X25M17A*80MSU0401712A*16.013.08.08,300217722522
EA*5X25M17A*80MSU0601716A*16.013.08.08,400217722529
EA*5X25M17A*80MSU0601716A*16.013.08.08,400217722528
EA*5X25M17A*80MSU0601716A*16.013.08.08,400217722530
EA*5X25M17A*+WALLCON*80CTL0701412B*16.013.08.08,400217722544
EA*5X25M17A*+WALLCON*80CTL0701412B*16.013.08.08,400217722545
EA*5X25M17A*+WALLCON*80CTL0701412B*16.013.08.08,400217722546
EA*5X25M17A*80VTL0451412B*16.013.08.08,400217722568
EA*5X25M17A*80VTL0451412B*16.013.08.08,400217722569
EA*5X25M17A*80VTL0451412B*16.013.08.08,400217722570
EA*5X25M17A*80VTL0701716B*16.013.08.08,400217722576
EA*5X25M17A*80VTL0701716B*16.013.08.08,400217722577
EA*5X25M17A*80VTL0701716B*16.013.08.08,400217722578
EA*5X19M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217721751
EA*5X19M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217721753
EA*5X19M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217721752
EA*5X25M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217722745
EA*5X25M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217722746
EA*5X25M17A*+WALLCON*96CTN0801714B*16.013.08.08,300217722747
FM(C,U)5Z30**AL-16.013.08.08,100217726356
FM(C,U)5Z30**AL-16.013.08.08,100217726357
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217722440
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217722441
EA*5X25M17A*80MS(N,L)0451412A*16.013.08.08,400217722442
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217721613
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217721614
EA*5X19M17A*92MSN0601714A*16.013.08.08,400217721615
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217721621
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217721622
EA*5X19M17A*92MSN0801716A*16.013.08.08,300217721623
EA*5X25M17A*80MS(N,L)0701412A*16.013.08.08,300217722456
EA*5X25M17A*80MS(N,L)0701412A*16.013.08.08,300217722457
EA*5X25M17A*80MS(N,L)0701412A*16.013.08.08,300217722458
EA*5X25M17A*80MS(N,L)0701712A*16.013.08.08,400217722464
EA*5X25M17A*80MS(N,L)0701712A*16.013.08.08,400217722465
EA*5X25M17A*80MS(N,L)0701712A*16.013.08.08,400217722466
EA*5X25M17A*80MS(N,L)0701716A*16.013.08.08,400217722472
EA*5X25M17A*80MS(N,L)0701716A*16.013.08.08,400217722473
EA*5X25M17A*80MS(N,L)0701716A*16.013.08.08,400217722474
EA*5X25M17A*80MS(N,L)0901714A*16.013.08.08,300217722480
EA*5X25M17A*80MS(N,L)0901714A*16.013.08.08,300217722481
EA*5X25M17A*80MS(N,L)0901714A*16.013.08.08,300217722482
EA*5X25M17A*80VSL0451412B*16.013.08.08,400217722488
EA*5X25M17A*80VSL0451412B*16.013.08.08,400217722489
EA*5X25M17A*80VSL0451412B*16.013.08.08,400217722490
EA*5X25M17A*80VSL0701412B*16.013.08.08,400217722496
EA*5X25M17A*80VSL0701412B*16.013.08.08,400217722497
EA*5X25M17A*80VSL0701412B*16.013.08.08,400217722498
EA*5X25M17A*80VSL0701716B*16.013.08.08,400217722504
EA*5X25M17A*80VSL0701716B*16.013.08.08,400217722505
EA*5X25M17A*80VSL0701716B*16.013.08.08,400217722506
EA*5X25M17A*80VSL0901716B*16.013.08.08,400217722512
EA*5X25M17A*80VSL0901716B*16.013.08.08,400217722513
EA*5X25M17A*80VSL0901716B*16.013.08.08,400217722514
EA*5X25M17A*+WALLCON*97CMN0801714B*16.013.08.08,400217722600
EA*5X25M17A*+WALLCON*97CMN0801714B*16.013.08.08,400217722601
EA*5X25M17A*+WALLCON*97CMN0801714B*16.013.08.08,400217722602
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil H5H6S19*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$561-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil H5H6S19*K*AAA?
The Heil H5H6S19*K*AAA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 228 certified matchups SEER2 ranges from 15.2-16.0.
Is the Heil H5H6S19*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Heil H5H6S19*K*AAA cost to run per year?
At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil H5H6S19*K*AAA the same as the Comfortmaker C5H6S19*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil H5H6S19*K*AAA?
ENERGY STAR lists 228 certified combinations for this outdoor unit. The highest-rated ones use FM(C,U)5Z30**AL, EA*5X25M17A, EA*5X25M17A*+WALLCON.
What refrigerant does the Heil H5H6S19*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $692/yrYou save $298/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H6S19*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$692
Current system, per year
$990
You save per year
$298
Payback
23.5 years
Net after 10 years
-$4,020

Cooling $420Heating $272Electricity used: 4,324 kWhSaved vs. a minimum-efficiency heat pump: $68

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.