HVAC Rated

1.5-ton central heat pump · 15 SEER2 HP

ECOTEMP W5H5S19*K*AAA

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #129 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $636 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
8,500 BTU/h43% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want a choice of indoor units - 56 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandECOTEMP
Also sold asGrandaire
Outdoor unit modelW5H5S19*K*AAA
Series15 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 31, 2025
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity17,700-19,300 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F18,400-19,500 BTU/h
Capacity at 17°F10,300-11,000 BTU/h
Capacity at 5°F7,900-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateNo
Heating output as it gets colder43% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FM(C,U)5Z30**AL at the standard test temperatures, in BTU/h:

Certified matchups56 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FM(C,U)5Z30**AL-16.013.08.08,100217687112
FM(C,U)5Z30**AL-16.013.08.08,100217687113
W5A*25M17XAWFSU060B048B*16.012.58.08,400217705783
W5A*25M17XAWFSU060B048B*16.012.58.08,400217705784
W5A*25M17XAWFE*045A036C*16.013.08.08,400217704937
W5A*25M17XAWFE*045A036C*16.013.08.08,400217704938
W5A*25M17XAWFE*070A036C*16.013.08.08,300217704987
W5A*25M17XAWFE*070A036C*16.013.08.08,300217704988
W5A*25M17XAWFE*070B036C*16.013.08.08,400217705012
W5A*25M17XAWFE*070B036C*16.013.08.08,400217705013
W5A*25M17XAWFE*070B048C*16.013.08.08,400217705039
W5A*25M17XAWFE*070B048C*16.013.08.08,400217705040
W5A*25M17XAWFE*090B042C*16.013.08.08,300217705066
W5A*25M17XAWFE*090B042C*16.013.08.08,300217705067
W5A*25M17XAWFEU040B036B*16.013.08.08,300217705173
W5A*25M17XAWFEU040B036B*16.013.08.08,300217705174
W5A*25M17XAWFEU060B048B*16.013.08.08,400217705200
W5A*25M17XAWFEU060B048B*16.013.08.08,400217705201
W5A*25M17XAWFET045A036A*16.013.08.08,400217705313
W5A*25M17XAWFET045A036A*16.013.08.08,400217705314
W5A*25M17XAWFET070A036A*16.013.08.08,400217705320
W5A*25M17XAWFET070A036A*16.013.08.08,400217705321
W5A*25M17XAWFET090B048A*16.013.08.08,400217705350
W5A*25M17XAWFET090B048A*16.013.08.08,400217705351
W5A*25M17XAWFAX060B042B*16.013.08.08,400217705493
W5A*25M17XAWFAX060B042B*16.013.08.08,400217705494
W5A*25M17XAWFAX080B048B*16.013.08.08,300217705520
W5A*25M17XAWFAX080B048B*16.013.08.08,300217705521
W5A*25M17XAWFSX080B048B*15.513.08.08,500217705650
W5A*25M17XAWFSX080B048B*15.513.08.08,500217705649
W5A*25M17XAWFST060B048A*15.513.08.08,400217705993
W5A*25M17XAWFST060B048A*15.513.08.08,400217705994
W5A*25M17XAWFJT060B048A*15.513.08.08,400217706018
W5A*25M17XAWFJT060B048A*15.513.08.08,400217706019
WCHL245*B-15.513.07.88,000217686953
WCHL245*B-15.513.07.88,000217686952
FM(C,U)5Z24**AL-15.513.07.88,100217687080
FM(C,U)5Z24**AL-15.513.07.88,100217687081
FMA5X18**AL-15.513.07.87,900217687208
FMA5X18**AL-15.513.07.87,900217687209
FMA5X24**AL-15.513.07.87,900217687240
FMA5X24**AL-15.513.07.87,900217687241
WCGL245*B-15.513.07.88,100217687283
WCGL245*B-15.513.07.88,100217687284
FM(C,U)5Z18**AL-15.513.07.88,100217687048
FM(C,U)5Z18**AL-15.513.07.88,100217687049
W5A*25M17XAWFSU040B036B*15.512.57.88,400217705756
W5A*25M17XAWFSU040B036B*15.512.57.88,400217705757
FM(C,U)5S24**AL-15.512.57.88,100218452469
FM(C,U)5S24**AL-15.512.57.88,100218452468
FM(C,U)5S18**AL-15.512.57.88,100218452450
FM(C,U)5S18**AL-15.512.57.88,100218452449
WCHL185*A-15.212.57.88,100217686888
WCHL185*A-15.212.57.88,100217686889
FMA5L18**AL-15.212.57.88,400217687144
FMA5L18**AL-15.212.57.88,400217687145
Yearly running cost in 10 large cities$561-$1,526

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the ECOTEMP W5H5S19*K*AAA?
The ECOTEMP W5H5S19*K*AAA is rated at up to 16.0 SEER2 and 13.0 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 56 certified matchups SEER2 ranges from 15.2-16.0.
Is the ECOTEMP W5H5S19*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the ECOTEMP W5H5S19*K*AAA cost to run per year?
At its rated efficiency it costs about $561-$1,526 a year in electricity in large U.S. cities, depending on climate and local rates - for example $695 in Phoenix and $1,277 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the ECOTEMP W5H5S19*K*AAA?
ENERGY STAR lists 56 certified combinations for this outdoor unit. The highest-rated ones use FM(C,U)5Z30**AL, W5A*25M17XA, WCHL245*B.
What refrigerant does the ECOTEMP W5H5S19*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $692/yrYou save $298/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump ECOTEMP W5H5S19*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$692
Current system, per year
$990
You save per year
$298
Payback
23.5 years
Net after 10 years
-$4,020

Cooling $420Heating $272Electricity used: 4,324 kWhSaved vs. a minimum-efficiency heat pump: $68

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.