HVAC Rated

3-ton central heat pump · GZV9SA

Goodman GZV9SA361CA

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #13 of 302 3 ton central heat pumps for cooling efficiency, and costs about $859 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
34,200 BTU/h100% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 34,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-32
General
BrandGoodman
Outdoor unit modelGZV9SA361CA
SeriesGZV9SA
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceNovember 10, 2025
Last certifiedJanuary 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 16.9-21.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity33,400-34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F31,000-34,200 BTU/h
Capacity at 17°F30,800-34,200 BTU/h
Capacity at 5°F31,000-34,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAHEA3630C3A*+MBVK16CH*X00A at the standard test temperatures, in BTU/h:

Certified matchups31 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAHEA3630C3A*+MBVK16CH*X00A · cold climate-21.012.010.034,200216699796
CA*EA6030*3A · cold climateG*VT800604B*A*19.011.79.232,600217971000
CA*EA6030*3A · cold climateG*VM970803BNA*19.011.79.232,600217971003
CA*EA6030*3A · cold climateG*VS800604BUA*19.011.79.232,600217971004
CA*EA6030*3A · cold climateG*VM970804CNA*19.011.79.232,600216699934
CA*EA6030*3A · cold climateG*VM971005CNA*19.011.79.232,600216699932
CA*EA6030*3A · cold climateG*VS800805CUA*19.011.79.232,600216699930
CA*EA6030*3A · cold climateG*VT800804C*A*19.011.79.232,600216699928
CA*EA6030*3A · cold climateG*VT800805C*A*19.011.79.232,600216699926
CA*EA6030*3A · cold climateG*VT801005C*A*19.011.79.232,600216699924
CA*EA6030*3A · cold climateG*VT960804CNA*19.011.79.232,600216699922
CA*EA6030*3A · cold climateG*VT961005CNA*19.011.79.232,600216699920
CA*EA6030*3A*+MBVK16CP1X00A · cold climate-19.011.79.232,600216699918
AHVE48CP0300A · cold climate-19.011.79.233,000216699916
AHVE48CP1300A · cold climate-19.011.79.233,000216699915
AHVE48DP0300A · cold climate-19.011.79.233,000216699914
AHVE48DP1300A · cold climate-19.011.79.233,000216699913
AHVE60DP0300A · cold climate-19.011.79.233,000216699912
AHVE60DP1300A · cold climate-19.011.79.233,000216699911
CHPEA4830*3A · cold climateG*VT800604B*A*18.211.09.031,000217970999
CHPEA4830*3A · cold climateG*VS800604BUA*18.211.09.031,000217971001
CHPEA4830*3A · cold climateG*VM970803BNA*18.211.09.031,000217971002
CHPEA4830*3A · cold climateG*VM970804CNA*18.211.09.031,000216699933
CHPEA4830*3A · cold climateG*VM971005CNA*18.211.09.031,000216699931
CHPEA4830*3A · cold climateG*VS800805CUA*18.211.09.031,000216699929
CHPEA4830*3A · cold climateG*VT800804C*A*18.211.09.031,000216699927
CHPEA4830*3A · cold climateG*VT800805C*A*18.211.09.031,000216699925
CHPEA4830*3A · cold climateG*VT801005C*A*18.211.09.031,000216699923
CHPEA4830*3A · cold climateG*VT961005CNA*18.211.09.031,000216699919
CHPEA4830*3A*+MBVK16CP1X00A · cold climate-18.211.09.031,000216699917
CHPEA4830*3A · cold climateG*VT960804CNA*16.911.08.531,000216699921
Yearly running cost in 10 large cities$765-$2,057

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Goodman GZV9SA361CA?
The Goodman GZV9SA361CA is rated at up to 21.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 31 certified matchups SEER2 ranges from 16.9-21.0.
Is the Goodman GZV9SA361CA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 34,200 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Goodman GZV9SA361CA cost to run per year?
At its rated efficiency it costs about $765-$2,057 a year in electricity in large U.S. cities, depending on climate and local rates - for example $945 in Phoenix and $1,719 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Goodman GZV9SA361CA?
ENERGY STAR lists 31 certified combinations for this outdoor unit. The highest-rated ones use CAHEA3630C3A*+MBVK16CH*X00A, CA*EA6030*3A, CA*EA6030*3A*+MBVK16CP1X00A.
What refrigerant does the Goodman GZV9SA361CA use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $938/yrYou save $799/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Goodman GZV9SA361CA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$938
Current system, per year
$1,737
You save per year
$799
Payback
16.3 years
Net after 10 years
-$5,011

Cooling $573Heating $365Electricity used: 5,865 kWhSaved vs. a minimum-efficiency heat pump: $390

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.