HVAC Rated

3-ton central heat pump · VANTIX

Sure SP19AY36AJVC

Excellent cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #16 of 302 3 ton central heat pumps for cooling efficiency, and costs about $886 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
29,600 BTU/h86% of its 47°F output
Very good · beats 76%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 29,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandSure
Also sold asRUSSELL
Outdoor unit modelSP19AY36AJVC
SeriesVANTIX
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableYes
On the market sinceSeptember 12, 2024
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 19.0-21.0)
EER2Efficiency at 95°F outdoors12.0-12.5
Cooling capacity34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F34,200 BTU/h
Capacity at 17°F30,000-31,200 BTU/h
Capacity at 5°F26,000-29,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.20
ENERGY STAR cold climateYes
Heating output as it gets colder86% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SHMVY3621MEACA at the standard test temperatures, in BTU/h:

Certified matchups38 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TCFY3621MEAAMS97MV1005A21DH21.012.010.029,400216051233
TCFY3621MEAAMS97MV1005A21DH21.012.010.029,400216051234
TCFY3621MEAAMS97MV0855A21DH21.012.010.029,400216051235
TCFY3621MEAAMS98MV1005A21UP21.012.010.029,400216051237
TCFY3621MEAAMS97MV0855A21DH21.012.010.029,400216051239
TCFY3621MEAAMS97MV0603A17DH21.012.010.029,600216051241
TCFY3621MEAAMS97MV0603A17DH21.012.010.029,600216051244
TCFY3621MEAAMS98MV1005A21UP21.012.010.029,400216051246
TCFY3621MEAAMS98MV0855A21UP21.012.010.029,400216051252
TCFY3621MEAAMS98MV0855A21UP21.012.010.029,400216051253
TCFY3621MEAAMS802V0504A17UH20.012.010.029,600216051226
TCFY3621MEAAMS802V1005A21UH20.012.010.029,200216051227
TCFY3621MEAAMS802V1005A21UH20.012.010.029,200216051228
TCFY3621MEAAMS802V0504A17UH20.012.010.029,600216051229
TCFY3621MEAAMS98MV0603A17UP20.012.010.029,600216051230
TCFY3621MEAAMS962V0703A17M420.012.010.029,600216051231
TCFY3621MEAAMS98MV0603A17UP20.012.010.029,600216051232
TCFY3621MEAAMS962V0703A17M420.012.010.029,600216051236
TCFY3621MEAAMS962V0603A17M420.012.010.029,600216051238
TCFY3621MEAAMS97MV0703A17DH20.012.010.029,600216051240
TCFY3621MEAAMS98MV0703A17UP20.012.010.029,600216051242
TCFY3621MEAAMS962V0403A17M420.012.010.029,600216051245
TCFY3621MEAAMS962V0403A17M420.012.010.029,600216051247
TCFY3621MEAAMS962V0603A17M420.012.010.029,600216051248
TCFY3621MEAAMS97MV0703A17DH20.012.010.029,600216051250
TCFY3621MEAAMS98MV0703A17UP20.012.010.029,600216051249
SHMVY3621MEACA · cold climate-20.012.59.529,400215576398
SHMVY3621MEACA · cold climate-20.012.59.529,400215576403
TCFY3621MEAAMS972V0855A21UPS20.012.08.526,000218728684
TCFY3621MEAAMS972V0855A21UPS20.012.08.526,000218728683
TCFY3621MEAAMS972V0705A21UPS20.012.08.526,000218728682
TCFY3621MEAAMS972V0705A21UPS20.012.08.526,000218728681
TCFY3621MEAAMS972V0603A17UPS20.012.08.526,200218728680
TCFY3621MEAAMS972V0603A17UPS20.012.08.526,200218728679
TCFY3621MEAAMS972V0403A17UPS20.012.08.526,200218814093
TCFY3621MEAAMS972V0403A17UPS20.012.08.526,200218814092
TCFY3621MEAAMS962V0855A21M419.012.010.029,400216051243
TCFY3621MEAAMS962V0855A21M419.012.010.029,400216051251
Yearly running cost in 10 large cities$767-$2,138

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Sure SP19AY36AJVC?
The Sure SP19AY36AJVC is rated at up to 21.0 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 38 certified matchups SEER2 ranges from 19.0-21.0.
Is the Sure SP19AY36AJVC good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 29,600 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Sure SP19AY36AJVC cost to run per year?
At its rated efficiency it costs about $767-$2,138 a year in electricity in large U.S. cities, depending on climate and local rates - for example $957 in Phoenix and $1,796 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Sure SP19AY36AJVC?
ENERGY STAR lists 38 certified combinations for this outdoor unit. The highest-rated ones use TCFY3621MEAAM, SHMVY3621MEACA.
What refrigerant does the Sure SP19AY36AJVC use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $956/yrYou save $807/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Sure SP19AY36AJVC
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$956
Current system, per year
$1,763
You save per year
$807
Payback
16.1 years
Net after 10 years
-$4,929

Cooling $573Heating $383Electricity used: 5,977 kWhSaved vs. a minimum-efficiency heat pump: $396

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.