HVAC Rated

4-ton central heat pump · Mainline 18 SEER2 HP

Heil H5H8T48*K*AAA

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #106 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,498 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
26,600 BTU/h50% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 1,245 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandHeil
Also sold asArcoaire, Airquest, Comfortmaker, Day & Night, Keeprite
Outdoor unit modelH5H8T48*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.7-13.5
Cooling capacity45,500-50,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F48,500-52,500 BTU/h
Capacity at 17°F29,400-32,400 BTU/h
Capacity at 5°F23,200-26,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D6021X at the standard test temperatures, in BTU/h:

Certified matchups1,245 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,245 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
QFVA5D6021X-18.013.08.525,800218695622
QFVA5D6021X-18.013.08.525,800218695621
QFVA5D6021X-18.013.08.525,800218695620
FTMA5B60L0D-18.013.58.124,600216151902
FTMA5B60L0D-18.013.58.124,600216152741
FTMA5B60L0D-18.013.58.124,600216152738
EVD5X61M24A*+WALLCON*97CMN1002122B*18.013.08.023,600216351343
EVD5X61M24A*+WALLCON*97CMN1002122B*18.013.08.023,600216351344
EVD5X61M24A*+WALLCON*97CMN1002122B*18.013.08.023,600216351345
EVD5X61M24A*+WALLCON*96CTN1002122B*18.013.08.023,600216351415
EVD5X61M24A*+WALLCON*96CTN1002122B*18.013.08.023,600216351416
EVD5X61M24A*+WALLCON*80CTL1352422B*18.013.08.023,400216351303
EVD5X61M24A*+WALLCON*80CTL1352422B*18.013.08.023,400216351304
EVD5X61M24A*+WALLCON*80CTL1352422B*18.013.08.023,400216351305
EVD5X61M24A*+WALLCON*80CTL0902120B*18.013.08.023,400216351295
EVD5X61M24A*+WALLCON*80CTL0902120B*18.013.08.023,400216351296
EVD5X61M24A*+WALLCON*80CTL0902120B*18.013.08.023,400216351297
EVD5X61M24A*+WALLCON*80CSU1002120B*18.013.08.023,600216351471
EVD5X61M24A*+WALLCON*80CSU1002120B*18.013.08.023,600216351472
EVD5X61M24A*+WALLCON*80CSU1002120B*18.013.08.023,600216351473
EVD5X61M24A*+WALLCON*96CTN1002122B*18.013.08.023,600216351417
EVD5X61M24A*+WALLCON*96CTN1202422B*18.013.08.023,600216351423
EVD5X61M24A*+WALLCON*96CTN1202422B*18.013.08.023,600216351424
EVD5X61M24A*+WALLCON*96CTN1202422B*18.013.08.023,600216351425
EVD5X61M24A*+WALLCON*80CSU0802120B*18.013.08.023,400216351463
EVD5X61M24A*+WALLCON*80CSU0802120B*18.013.08.023,400216351464
EVD5X61M24A*+WALLCON*80CSU0802120B*18.013.08.023,400216351465
EVD5X61M24A*+WALLCON*97CTN1002122A*18.013.08.023,600216351487
EVD5X61M24A*+WALLCON*97CTN1002122A*18.013.08.023,600216351488
EVD5X61M24A*+WALLCON*97CTN1002122A*18.013.08.023,600216351489
EVD5X61M24A*+WALLCON*97CTN1202422A*18.013.08.023,600216351495
EVD5X61M24A*+WALLCON*97CTN1202422A*18.013.08.023,600216351496
EVD5X61M24A*+WALLCON*97CTN1202422A*18.013.08.023,600216351497
EVD5X61M21A*+WALLCON*80CTL0902120B*18.013.08.023,600216351054
EVD5X61M21A*+WALLCON*80CTL0902120B*18.013.08.023,600216351055
EVD5X61M21A*+WALLCON*80CTL0902120B*18.013.08.023,600216351056
EVD5X61M21A*+WALLCON*80CTL1102120B*18.013.08.023,600216351062
EVD5X61M21A*+WALLCON*80CTL1102120B*18.013.08.023,600216351063
EVD5X61M21A*+WALLCON*80CSU1002120A*18.012.08.025,200216350998
EVD5X61M21A*+WALLCON*80CSU1002120A*18.012.08.025,200216350999
EVD5X61M21A*+WALLCON*80CSU1002120A*18.012.08.025,200216351000
EVD5X61M21A*+WALLCON*80CTL1102120B*18.013.08.023,600216351064
EVD5X61M21A*+WALLCON*80CSU0802120B*18.013.08.023,400216351207
EVD5X61M21A*+WALLCON*80CSU0802120B*18.013.08.023,400216351208
EVD5X61M21A*+WALLCON*80CSU0802120B*18.013.08.023,400216351209
EVD5X61M21A*96VTN1002122B*17.512.58.524,600216351199
EVD5X61M21A*96VTN1002122B*17.512.58.524,600216351200
EVD5X61M21A*97VTN1002122A*17.512.58.524,600216351255
EVD5X61M21A*97VTN1002122A*17.512.58.524,600216351256
EVD5X61M21A*97VTN1002122A*17.512.58.524,600216351257
EVD5X61M24A*95MSU1002122A*17.512.58.525,000216351399
EVD5X61M24A*95MSU1002122A*17.512.58.525,000216351400
EVD5X61M24A*95MSU1002122A*17.512.58.525,000216351401
EVD5X61M24A*80VSL1102122B*17.512.58.525,000216351271
EVD5X61M24A*80VSL1102122B*17.512.58.525,000216351272
EVD5X61M24A*80VSL1102122B*17.512.58.525,000216351273
EVD5X61M24A*96VTN1002122B*17.512.58.524,800216351447
EVD5X61M24A*96VTN1002122B*17.512.58.524,800216351448
EVD5X61M24A*96VTN1002122B*17.512.58.524,800216351449
EVD5X61M24A*97VTN1002122A*17.512.58.524,800216351519
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Heil H5H8T48*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,258-$3,646

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Heil H5H8T48*K*AAA?
The Heil H5H8T48*K*AAA is rated at up to 18.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1245 certified matchups SEER2 ranges from 15.2-18.0.
Is the Heil H5H8T48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Heil H5H8T48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,258-$3,646 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,589 in Phoenix and $3,076 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Heil H5H8T48*K*AAA the same as the Comfortmaker C5H8T48*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Heil H5H8T48*K*AAA?
ENERGY STAR lists 1245 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D6021X, FTMA5B60L0D, EVD5X61M24A*+WALLCON.
What refrigerant does the Heil H5H8T48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,597/yrYou save $910/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Heil H5H8T48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,597
Current system, per year
$2,508
You save per year
$910
Payback
19.8 years
Net after 10 years
-$8,898

Cooling $939Heating $659Electricity used: 9,984 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.