HVAC Rated

4-ton central heat pump · Mainline 18 SEER2 HP

Tempstar T5H8T48*K*AAA

Average cooling efficiency and below average heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #109 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,498 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
26,600 BTU/h50% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 415 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandTempstar
Outdoor unit modelT5H8T48*K*AAA
SeriesMainline 18 SEER2 HP
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedSeptember 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.2-18.0)
EER2Efficiency at 95°F outdoors11.7-13.5
Cooling capacity45,500-50,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F48,500-52,500 BTU/h
Capacity at 17°F29,400-32,400 BTU/h
Capacity at 5°F23,200-26,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with QFVA5D6021X at the standard test temperatures, in BTU/h:

Certified matchups415 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 415 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
QFVA5D6021X-18.013.08.525,800218695626
FTMA5B60L0D-18.013.58.124,600216152755
EVD5X61M21A*+WALLCON*80CSU0802120B*18.013.08.023,400216351214
EVD5X61M24A*+WALLCON*80CTL0902120B*18.013.08.023,400216351302
EVD5X61M24A*+WALLCON*80CTL1352422B*18.013.08.023,400216351310
EVD5X61M24A*+WALLCON*80CSU0802120B*18.013.08.023,400216351470
EVD5X61M24A*+WALLCON*80CSU1002120B*18.013.08.023,600216351478
EVD5X61M24A*+WALLCON*97CMN1002122B*18.013.08.023,600216351350
EVD5X61M24A*+WALLCON*96CTN1002122B*18.013.08.023,600216351422
EVD5X61M24A*+WALLCON*96CTN1202422B*18.013.08.023,600216351430
EVD5X61M24A*+WALLCON*97CTN1002122A*18.013.08.023,600216351494
EVD5X61M24A*+WALLCON*97CTN1202422A*18.013.08.023,600216351502
EVD5X61M21A*+WALLCON*80CTL0902120B*18.013.08.023,600216351061
EVD5X61M21A*+WALLCON*80CSU1002120A*18.012.08.025,200216351005
EVD5X61M21A*+WALLCON*80CTL1102120B*18.013.08.023,600216351069
EVD5X61M21A*97VTN1002122A*17.512.58.524,600216351262
EVD5X61M24A*95MSU1002122A*17.512.58.525,000216351406
EVD5X61M24A*80VSL1102122B*17.512.58.525,000216351278
EVD5X61M24A*96VTN1002122B*17.512.58.524,800216351454
EVD5X61M24A*97VTN1002122A*17.512.58.524,800216351526
EVD5X61M21A*80MSU0802120A*17.513.08.524,400216351037
EVD5X61M24A*80VTL1102122B*17.512.58.524,800216351326
EVD5X61M21A*96VTN1002122B*17.512.58.524,600216351206
EVD5X61M21A*80VSL1102122B*17.512.58.524,800216351021
EVD5X61M21A*80MSU1002120A*17.512.58.525,000216351045
EVD5X61M21A*95MSU1002122A*17.512.58.124,400216351166
EVD5X49M24A*80MSU0802120A*17.512.58.124,600216350573
EVM5X60M21A*80MSU0802120A*17.512.58.124,400216350021
EVM5X60M21A*96VTN1002122B*17.512.58.124,400216350189
EVD5X60M21A*96VTN1002122B*17.512.58.124,400216350933
EVD5X61M21A*80MSU0601716A*17.512.08.125,000216351029
EVD5X61M21A*80VTL1102122B*17.512.58.124,600216351085
EVM5X49M21A*80MSU0802120A*17.512.58.124,400216349765
QFVA5D4821X-17.512.58.125,400218695619
EVD5X61M21A*+WALLCON*97CMN0802120B*17.512.58.023,800216351118
EVD5X61M21A*+WALLCON*97CMN1002122B*17.513.08.023,600216351126
EVM5X49M21A*+WALLCON*95CSU1002122B*17.512.58.023,600216349821
EVD5X61M21A*+WALLCON*80CSU1002120B*17.513.08.023,600216351222
EVD5X61M21A*+WALLCON*97CTN0802120A*17.512.58.023,800216351230
EVD5X61M21A*+WALLCON*97CTN1002122A*17.513.08.023,600216351238
EVD5X49M24A*+WALLCON*80CTL0902120B*17.512.58.023,400216350581
EVD5X49M24A*+WALLCON*96CTN1202422B*17.512.58.023,400216350669
EVD5X61M24A*+WALLCON*97CMN1202422B*17.513.08.023,600216351358
EVD5X61M24A*+WALLCON*96CTN0802120B*17.512.58.023,600216351414
EVD5X61M24A*+WALLCON*80CTL0702120B*17.512.58.023,800216351294
EVM5X49M21A*+WALLCON*96CTN1002122B*17.512.58.023,600216349901
EVM5X49M21A*+WALLCON*80CSU0802120B*17.513.08.023,400216349933
EVD5X49M24A*+WALLCON*97CTN1202422A*17.512.58.023,400216350709
EVM5X49M21A*+WALLCON*80CSU1002120B*17.512.58.023,600216349941
EVM5X49M21A*+WALLCON*97CTN1002122A*17.512.58.023,600216349957
EVM5X60M21A*+WALLCON*80CSU1002120A*17.512.08.025,200216349989
EVD5X60M21A*80MSU0802120A*17.512.58.024,400216350773
EVD5X60M21A*+WALLCON*80CSU1002120A*17.512.08.025,200216350741
EVM5X60M21A*+WALLCON*80CTL0902120B*17.512.58.023,600216350045
EVM5X60M21A*+WALLCON*80CTL1102120B*17.512.58.023,600216350053
EVM5X60M21A*+WALLCON*95CSU1002122B*17.512.58.023,600216350085
EVD5X61M24A*+WALLCON*97CTN0802120A*17.512.58.023,600216351486
EVD5X60M21A*+WALLCON*80CTL0902120B*17.512.58.023,600216350797
EVD5X60M21A*+WALLCON*80CTL1102120B*17.512.58.023,600216350805
EVD5X60M21A*+WALLCON*95CSU1002122B*17.512.58.023,400216350837
Yearly running cost in 10 large cities$1,258-$3,646

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar T5H8T48*K*AAA?
The Tempstar T5H8T48*K*AAA is rated at up to 18.0 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 415 certified matchups SEER2 ranges from 15.2-18.0.
Is the Tempstar T5H8T48*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the Tempstar T5H8T48*K*AAA cost to run per year?
At its rated efficiency it costs about $1,258-$3,646 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,589 in Phoenix and $3,076 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar T5H8T48*K*AAA?
ENERGY STAR lists 415 certified combinations for this outdoor unit. The highest-rated ones use QFVA5D6021X, FTMA5B60L0D, EVD5X61M21A*+WALLCON.
What refrigerant does the Tempstar T5H8T48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,597/yrYou save $910/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar T5H8T48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,597
Current system, per year
$2,508
You save per year
$910
Payback
19.8 years
Net after 10 years
-$8,898

Cooling $939Heating $659Electricity used: 9,984 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 15, 2026. How we use the data.