4-ton central heat pump · 2-STAGE 17 SEER HP
WeatherMaker PH7TAN448**AA
Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.
Ranks #249 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,603 a year to run in a mixed climate like Atlanta.
- SEER2
- 16.0 Cooling efficiency over a seasonBelow average · beats 26%
- HSPF2
- 8.1 Heating efficiency over a seasonBelow average · beats 20%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- - Not reported by the maker
A good fit if…
- You want a certified 4-ton central heat pump at a typical efficiency level.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | WeatherMaker |
| Outdoor unit model | PH7TAN448**AA |
| Series | 2-STAGE 17 SEER HP |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | May 1, 2022 |
| Last certified | December 12, 2023 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 16.0 (range 16.0) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 46,000-46,500 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.1 |
| Capacity at 47°F | 50,500 BTU/h |
| Capacity at 17°F | 30,600-30,800 BTU/h |
| Capacity at 5°F | - |
| COP at 5°F2.0 = twice as efficient as a space heater | - |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM4X49M21A at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| EVM4X49M21A | PG80MSUA60080C** | 16.0 | 11.7 | 8.1 | - | 213636443 |
| EVM4X49M21A | PG80VTLB66110C** | 16.0 | 11.7 | 8.1 | - | 213636581 |
| EVM4X60M21A | PG80MSUA60080C** | 16.0 | 11.7 | 8.1 | - | 213637079 |
| EVM4X60M21A | PG80VTLB66110C** | 16.0 | 11.7 | 8.1 | - | 213637233 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,719/yr
- Miami, FL$1,369/yr
- Houston, TX$1,542/yr
- Atlanta, GA$1,603/yr
- Los Angeles, CA$1,569/yr
- New York, NY$3,883/yr
- Chicago, IL$3,163/yr
- Denver, CO$2,638/yr
- Seattle, WA$1,627/yr
- Minneapolis, MN$3,268/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the WeatherMaker PH7TAN448**AA?
- The WeatherMaker PH7TAN448**AA is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the WeatherMaker PH7TAN448**AA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
- How much does the WeatherMaker PH7TAN448**AA cost to run per year?
- At its rated efficiency it costs about $1,369-$3,883 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,719 in Phoenix and $3,268 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the WeatherMaker PH7TAN448**AA?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use EVM4X49M21A, EVM4X60M21A.
- What refrigerant does the WeatherMaker PH7TAN448**AA use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Trane 5HPL5048A1000AA · cold climate16.0 SEER2 · 8.1 HSPF2
- York YH2F48TB2116.0 SEER2 · 8.1 HSPF2
- Sure SP15AY48AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- York YH548E2S1116.0 SEER2 · 8.1 HSPF2
- Rheem WP15AY48AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- York YH648E2S1116.0 SEER2 · 8.1 HSPF2
- Rheem RP15AY48AJ2N · cold climate16.0 SEER2 · 8.1 HSPF2
- Frigidaire FSH4BF5M2SX48K16.0 SEER2 · 8.0 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of December 12, 2023. How we use the data.