HVAC Rated

4-ton central heat pump · LX SERIES

York YH548E2S11

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #251 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,527 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
27,200 BTU/h56% of its 47°F output
Excellent · beats 96%

A good fit if…

  • You want a choice of indoor units - 381 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandYork
Outdoor unit modelYH548E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 9, 2024
Last certifiedSeptember 22, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity45,500-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F45,000-48,000 BTU/h
Capacity at 17°F29,200-32,400 BTU/h
Capacity at 5°F24,600-27,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.10-2.42
ENERGY STAR cold climateNo
Heating output as it gets colder56% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM60C5CHS1 at the standard test temperatures, in BTU/h:

Certified matchups381 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 381 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM60C5CHS1Y82V100C16SMPC116.012.07.826,200217444706
CTF60C5CHS1Y82V120C20SMPC116.012.07.826,400217444704
CTM60C5CHS1Y82V080C16SMPC116.012.07.826,200217444703
CTM60C5CHS1Y82V120C20SMPC116.012.07.826,000217444701
CTM60C5CHS1Y82V100C20SMPC116.012.07.826,400217444700
CTM60C5CHS2Y82V100C16SMPC116.012.07.826,200218500859
CTM60C5CHS2Y82V120C20SMPC116.012.07.826,000218500857
CTM60C5CHS2Y82V100C20SMPC116.012.07.826,400218500854
CTM60C5CHS2Y82V080C16SMPC116.012.07.826,200218500851
CTF60C5CHS2Y82V120C20SMPC116.012.07.826,400218500369
JHE60C5CH2SS1-15.212.08.126,400214425107
JHC60D5CH2SS1-15.212.08.126,400214425532
JHE60D5CH2SS1-15.212.08.126,200214425534
JHC60C5CH2SS1-15.211.78.126,600214425979
CTM60C5CHS1Y82E100C20LMPS115.212.08.126,200216437616
CTM60C5CHS1Y81E120C16SMPS115.212.08.126,400214424784
CTM60D5CHS1+JME18D2SN1-15.212.08.126,200214424781
CTM60D5CHS1+JMET18DS2N1-15.212.08.126,200214424902
CTM60C5CHS1Y81E100C16SMPS115.211.78.126,600214424852
CTM60C5CHS1+JMET16CS2N1-15.212.08.126,400214424900
CTM60D5CHS1Y81E130D20SMPS115.212.08.126,400214424854
CTM60C5CHS1Y81E080C20SMPS115.212.08.126,200214425020
CTM60D5CHS1+JMVT20DC2N1-15.212.08.126,200214425304
CTM60C5CHS1+JMC16C2SN1-15.212.08.126,200214425302
CTM60C5CHS1Y81E120C20SMPS115.212.08.126,200214425536
CTM60C5CHS1Y81E100C20SMPS115.212.08.126,200214425437
CTM60C5CHS1+JME16C2SN1-15.212.08.126,200214425672
CTM60D5CHS1+JMC20D2SN1-15.212.08.126,200214425782
CTM60C5CHS1+JMC17C2SN1-15.212.08.126,200214425983
CTM60C5CHS1+JMVT17CC2N1-15.212.08.126,200214425981
CTM60C5CHS1+JMVT16CC2N1-15.212.08.126,200214430029
CTM60C5CHS1+JME12C2SN1-15.212.08.125,800214430037
CTF60C5CHS1Y81E120C16SMPS115.211.78.126,400214425609
CTF60D5CHS1+JME18D2SN1-15.212.08.126,000214425674
CTF60D5CHS1+JMC20D2SN1-15.212.08.126,200214424780
CTF60D5CHS1+JMVT20DC2N1-15.212.08.126,200214425015
CTF60D5CHS1+JMET18DS2N1-15.212.08.126,000214425110
CTF60C5CHS1+JME16C2SN1-15.212.08.126,000214425197
CTF60C5CHS1Y81E100C20SMPS115.211.78.126,200214425163
CTF60D5CHS1Y81E130D20SMPS115.211.78.126,600214425278
CTF60C5CHS1+JMET16CS2N1-15.211.78.126,200214425538
CTU60D5XHS1+TXVY81E130D20SMPS115.211.78.126,600214650207
CTU60D5XHS1+JMET18DS2N1+TXV-15.212.08.126,000214807463
CTU60D5XHS1+JMVT20DC2N1+TXV-15.212.08.126,200214807464
CTU60D5XHS1+JME18D2SN1+TXV-15.212.08.126,000214807466
CTU60D5XHS1+JMC20D2SN1+TXV-15.212.08.126,200214807465
CTM60C5CHS1Y81E100C20LMPS115.212.08.126,200216780642
CTM60C5CHS1Y81E080C20LMPS115.212.08.126,200216779920
CTM60C5CHS1Y81E120C20LMPS115.212.08.126,200216780779
CTF60C5CHS1Y81E120C16LMPS115.211.78.126,400216780928
CTF60C5CHS1Y81E100C20LMPS115.211.78.126,200216780346
CTF60D5CHS1Y81E130D20LMPS115.211.78.126,600216780351
CTU60D5XHS1+TXVY81E130D20LMPS115.211.78.126,600216780356
CTM60C5CHS1Y81E120C16LMPS115.212.08.126,400216779709
CTM60C5CHS1Y81E100C16LMPS115.211.78.126,600216779714
CTM60D5CHS1Y81E130D20LMPS115.212.08.126,400216779720
JHE60C5CH2SS2-15.212.08.126,400218456674
JHE60D5CH2SS2-15.212.08.126,200218456672
CTM60D5CHS2+JMC20D2SN1-15.212.08.126,200218500906
CTM60D5CHS2Y81E130D20LMPS115.212.08.126,400218500904
Yearly running cost in 10 large cities$1,380-$3,639

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH548E2S11?
The York YH548E2S11 is rated at up to 16.0 SEER2 and 12.0 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 381 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH548E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the York YH548E2S11 cost to run per year?
At its rated efficiency it costs about $1,380-$3,639 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,694 in Phoenix and $3,035 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH548E2S11?
ENERGY STAR lists 381 certified combinations for this outdoor unit. The highest-rated ones use CTM60C5CHS1, CTF60C5CHS1, CTM60C5CHS2.
What refrigerant does the York YH548E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,677/yrYou save $738/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH548E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,677
Current system, per year
$2,415
You save per year
$738
Payback
23.7 years
Net after 10 years
-$10,117

Cooling $1,034Heating $643Electricity used: 10,481 kWhSaved vs. a minimum-efficiency heat pump: $174

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 22, 2026. How we use the data.