HVAC Rated

4-ton central heat pump · LX SERIES

York YH2F48TB21

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #250 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,468 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
29,800 BTU/h55% of its 47°F output
Excellent · beats 100%

A good fit if…

  • You want a choice of indoor units - 327 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandYork
Outdoor unit modelYH2F48TB21
SeriesLX SERIES
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMay 18, 2023
Last certifiedJuly 15, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors10.5-12.0
Cooling capacity44,500-47,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F43,500-48,000 BTU/h
Capacity at 17°F29,200-34,200 BTU/h
Capacity at 5°F23,400-29,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.20-2.84
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHC60GBCN1 at the standard test temperatures, in BTU/h:

Certified matchups327 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 327 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAHC60GBCN1Y81E120C16LMPS116.011.78.125,200212475735
XAHC60GBCN1Y81E120C16SMPS116.011.78.125,200212413513
XAHC60GBCN1Y81E080C16LMPS116.011.78.125,000212475739
XAHC60HBCN1Y81E080C20SMPS116.011.78.124,400212413553
XAHC60HBCN1Y81E100C20LMPS116.011.78.124,400212475955
XAHC60HBCN1Y81E080C16LMPS116.011.78.124,400212475747
XAHD60GBCN1Y81E130D20SMPS116.011.78.125,400212413507
XAHC60GBCN1Y81E080C16SMPS116.011.78.125,000212413527
XAHC60HBCN1Y82E100C20LMPS116.011.78.124,400212413533
XAHD60HBCN1Y82E100C20LMPS116.011.78.124,400212413531
XAHC60HBCN1Y82E080C16LMPS116.011.78.124,400212413540
XAHC60HBCN1Y81E100C20SMPS116.011.78.124,400212413549
XAHC60HBCN1Y81E080C16SMPS116.011.78.124,400212413557
XAHD60GBCN1Y81E130D20LMPS116.011.78.125,400212475275
XAHC60HBCN1Y81E080C20LMPS116.011.78.124,400212475522
XAHC60HBCN1YPLC100C20MP1316.011.78.125,000210338656
XAHC60HBCN1TMLV100C16MP1216.011.78.124,600210339280
XAHC60HBCN1YPLC080C16MP1316.011.78.124,600210339283
XAHC60HBCN1TPLC080C16MP1316.011.78.124,600210339281
XAHC60HBCN1YPLC100C16MP1316.011.78.124,600210339284
XAHC60HBCN1TPLC100C16MP1316.011.78.124,600210339282
XAHD60HBCN1TM8E080C16MP1116.011.78.124,600210338688
XAHD60HBCN1TMLE080C16MP1116.011.78.124,600210338689
XAHD60HBCN1TMLV120C20MP1216.011.78.124,800210338641
XAHD60HBCN1TPLC100C20MP1316.011.78.124,800210338642
XAHC60HBCN1TMLV120C20MP1216.011.78.125,000210338653
XAHD60HBCN1TPLC120C20MP1316.011.78.124,800210338643
XAHD60HBCN1YPLC120C20MP1316.011.78.124,800210338645
XAHC60HBCN1TPLC100C20MP1316.011.78.125,000210338654
XAHD60HBCN1YPLC100C20MP1316.011.78.124,800210338644
XAHC60HBCN1YPLC120C20MP1316.011.78.125,000210338657
XAHC60HBCN1TPLC120C20MP1316.011.78.125,000210338655
XAHC60HBCN1TM8E120C20MP1116.011.78.125,000210340587
XAHC60HBCN1TMLE080C16MP1116.011.78.124,600210339943
XAHC60HBCN1TM8E080C16MP1116.011.78.124,600210339942
XAHC60HBCN1TMLE120C20MP1116.011.78.125,000210340588
XAHD60HBCN1TMLE100C16MP1116.011.78.125,000210340596
XAHD60HBCN1TM8E100C16MP1116.011.78.125,000210340595
XAHD60HBCN1TMLE120C16MP1116.011.78.125,000210341362
XAHC60HBCN1TM8E120C16MP1116.011.78.124,600210341365
XAHD60HBCN1TM8E120C16MP1116.011.78.125,000210341361
XAHC60HBCN1TMLE120C16MP1116.011.78.124,600210341366
XAHC60HBCN1TMLE100C20MP1116.011.78.125,400210341370
XAHC60HBCN1TM8E100C20MP1116.011.78.125,400210341369
XAHC60HBCN1TMLE080C20MP1116.011.78.125,400210337948
XAHD60HBCN1TM8E080C20MP1116.011.78.125,200210341379
XAHC60HBCN1TM8E100C16MP1116.011.78.125,000210337943
XAHC60HBCN1TMLE100C16MP1116.011.78.125,000210337944
XAHD60HBCN1TMLE080C20MP1116.011.78.125,200210341380
XAHC60HBCN1TM8E080C20MP1116.011.78.125,400210337947
XAHD60HBCN1TM8V100C20MP1216.011.78.124,800210338640
XAHC60HBCN1TM8Y120C20MP1116.011.78.125,000210338627
XAHC60HBCN1TM8Y100C20MP1116.011.78.125,000210338628
XAHD60HBCN1TM8Y120C20MP1116.011.78.125,000210337888
XAHD60HBCN1TM8Y100C20MP1116.011.78.125,000210337889
JHVTD60HBCC2N1-16.012.08.123,600210339948
JHETD60HBCS2N1-16.011.78.123,800210340634
XAHC60HBCN1TM8Y100C16MP1116.011.78.125,000210341326
XAHC60HBCN1TM8Y080C16MP1116.011.78.125,000210341327
XAHD60HBCN1TM9Y120D20MP1116.011.78.125,000210339232
Yearly running cost in 10 large cities$1,335-$3,490

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH2F48TB21?
The York YH2F48TB21 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 327 certified matchups SEER2 ranges from 15.2-16.0.
Is the York YH2F48TB21 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the York YH2F48TB21 cost to run per year?
At its rated efficiency it costs about $1,335-$3,490 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,635 in Phoenix and $2,907 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH2F48TB21?
ENERGY STAR lists 327 certified combinations for this outdoor unit. The highest-rated ones use XAHC60GBCN1, XAHC60HBCN1, XAHD60GBCN1.
What refrigerant does the York YH2F48TB21 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,616/yrYou save $713/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH2F48TB21
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,616
Current system, per year
$2,330
You save per year
$713
Payback
23.8 years
Net after 10 years
-$9,866

Cooling $1,001Heating $615Electricity used: 10,102 kWhSaved vs. a minimum-efficiency heat pump: $168

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 15, 2026. How we use the data.