HVAC Rated

3.5-ton central heat pump · SoftSound 23 VS Heat Pump

Comfortmaker C5H3V48*K*AAA

Excellent cooling efficiency and very good heating efficiency for a 3.5-ton central heat pump, and certified for cold climates.

Ranks #3 of 138 3.5 ton central heat pumps for cooling efficiency, and costs about $1,230 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
38,500 BTU/h74% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3.5 ton, R-454B
General
BrandComfortmaker
Also sold asDay & Night, Keeprite
Outdoor unit modelC5H3V48*K*AAA
SeriesSoftSound 23 VS Heat Pump
TypeCentral heat pump
Nominal size3.5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 19.5-23.0)
EER2Efficiency at 95°F outdoors10.0-12.5
Cooling capacity43,000-46,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-9.5
Capacity at 47°F48,000-53,500 BTU/h
Capacity at 17°F39,000-43,500 BTU/h
Capacity at 5°F35,600-38,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups414 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 414 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931510
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931511
FCMA5B60L0D*+WALLCON · cold climate-23.012.59.535,600215931509
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934619
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934620
FCMA5B48L0C*+WALLCON · cold climate-22.012.09.536,000215934621
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934189
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934190
EA*5X61M21A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934191
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934229
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934230
EA*5X61M21A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934231
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934109
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934110
EA*5X60M24A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,200215934111
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934119
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934120
EA*5X60M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,200215934121
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941049
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941050
EA*5X61M21A*+WALLCON · cold climate*80CSU0401712B*21.511.59.536,800215941051
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941120
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941119
EA*5X61M24A*+WALLCON · cold climate*97CTN1002122A*21.511.09.536,800215941121
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941129
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941130
EA*5X61M24A*+WALLCON · cold climate*97CTN1202422A*21.511.59.536,600215941131
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934419
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934420
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*21.511.59.536,800215934421
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934409
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934410
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*21.511.09.536,600215934411
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934389
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934390
EA*5X61M24A*+WALLCON · cold climate*97CMN1002122B*21.511.09.536,600215934391
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934359
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934360
EA*5X61M24A*+WALLCON · cold climate*95CSU1002122B*21.511.59.536,600215934361
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934199
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934200
EA*5X61M21A*+WALLCON · cold climate*80CTL1102120B*21.511.09.536,800215934201
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934339
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934340
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*21.511.59.536,600215934341
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934329
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934330
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*21.511.59.536,600215934331
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934319
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934320
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*21.511.59.536,600215934321
EA*5X60M24A*+WALLCON · cold climate*95CSU0802120B*21.011.09.536,600215934129
EA*5X60M24A*+WALLCON · cold climate*95CSU0802120B*21.011.09.536,600215934130
EA*5X60M24A*+WALLCON · cold climate*95CSU0802120B*21.011.09.536,600215934131
EA*5X61M21A*+WALLCON · cold climate*80CSU1002120A*21.011.09.537,000215934139
EA*5X61M21A*+WALLCON · cold climate*80CSU1002120A*21.011.09.537,000215934140
EA*5X61M21A*+WALLCON · cold climate*80CSU1002120A*21.011.09.537,000215934141
EA*5X61M21A*+WALLCON · cold climate*95CSU0802120B*21.011.09.537,000215934219
EA*5X61M21A*+WALLCON · cold climate*95CSU0802120B*21.011.09.537,000215934220
EA*5X61M21A*+WALLCON · cold climate*95CSU0802120B*21.011.09.537,000215934221
Yearly running cost in 10 large cities$929-$3,078

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Comfortmaker C5H3V48*K*AAA?
The Comfortmaker C5H3V48*K*AAA is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 414 certified matchups SEER2 ranges from 19.5-23.0.
Is the Comfortmaker C5H3V48*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Comfortmaker C5H3V48*K*AAA cost to run per year?
At its rated efficiency it costs about $929-$3,078 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,227 in Phoenix and $2,635 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Comfortmaker C5H3V48*K*AAA?
ENERGY STAR lists 414 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, FCMA5B48L0C*+WALLCON, EA*5X61M21A*+WALLCON.
What refrigerant does the Comfortmaker C5H3V48*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,260/yrYou save $1,117/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Comfortmaker C5H3V48*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,260
Current system, per year
$2,378
You save per year
$1,117
Payback
15.2 years
Net after 10 years
-$5,829

Cooling $689Heating $572Electricity used: 7,878 kWhSaved vs. a minimum-efficiency heat pump: $571

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3.5 ton models

See all 138 3.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.